These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 7270654)

  • 1. Physical fitness and intraocular pressure.
    Sargent RG; Blair SN; Magun JC; Krejci RC; Sacoco C; Langley TD; Taylor RL
    Am J Optom Physiol Opt; 1981 Jun; 58(6):460-6. PubMed ID: 7270654
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of physical fitness on intraocular pressure in Chinese medical students.
    Qureshi IA; Xi XR; Wu XD; Zhang J; Shiarkar E
    Zhonghua Yi Xue Za Zhi (Taipei); 1996 Nov; 58(5):317-22. PubMed ID: 9037846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Resting intraocular pressure of steel factory workers is related to their physical fitness.
    Qureshi IA; Wu XD; Xi XR; Yang J; Huang YB
    Ind Health; 1997 Apr; 35(2):259-63. PubMed ID: 9127559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Study on changes of intraocular pressure within 24 hours in primary open angle glaucoma and normal eyes].
    Xiao M; Sun XH; Meng FR; Fang ZB; Qiu SY; Guo WY; Qian SH; Wang JY
    Zhonghua Yi Xue Za Zhi; 2011 Feb; 91(7):441-4. PubMed ID: 21418972
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does physical fitness influence intraocular pressure?
    Qureshi IA
    J Pak Med Assoc; 1997 Mar; 47(3):81-4. PubMed ID: 9131859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of Intraocular Pressure by Patients With Glaucoma.
    Pronin S; Brown L; Megaw R; Tatham AJ
    JAMA Ophthalmol; 2017 Oct; 135(10):1030-1036. PubMed ID: 28859192
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraocular pressure curves of untreated glaucoma suspects and glaucoma patients in sitting and lateral decubitus positions using the goldmann applanation tonometer.
    Piven I; Glovinsky Y
    J Glaucoma; 2014; 23(8):541-6. PubMed ID: 25055215
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measured Changes in Limbal Strain During Simulated Sleep in Face Down Position Using an Instrumented Contact Lens in Healthy Adults and Adults With Glaucoma.
    Flatau A; Solano F; Idrees S; Jefferys JL; Volpe P; Damion C; Quigley HA
    JAMA Ophthalmol; 2016 Apr; 134(4):375-82. PubMed ID: 26795708
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraocular pressure, ocular pulse pressure, and body position.
    Buchanan RA; Williams TD
    Am J Optom Physiol Opt; 1985 Jan; 62(1):59-62. PubMed ID: 3976837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is the tono-pen accurate for measuring intraocular pressure in young children with congenital glaucoma?
    Levy J; Lifshitz T; Rosen S; Tessler Z; Biedner BZ
    J AAPOS; 2005 Aug; 9(4):321-5. PubMed ID: 16102480
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effects of betaxolol hydrochloride ophthalmic solution on intraocular pressures during transient microgravity.
    Pattinson TJ; Gibson CR; Manuel FK; Bishop SL; March WF
    Aviat Space Environ Med; 1999 Oct; 70(10):1012-7. PubMed ID: 10519481
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry.
    Hoffmann EM; Grus FH; Pfeiffer N
    BMC Ophthalmol; 2004 Mar; 4():4. PubMed ID: 15038831
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of exercise on intraocular pressure in physically fit subjects.
    Qureshi IA
    Clin Exp Pharmacol Physiol; 1996 Aug; 23(8):648-52. PubMed ID: 8886483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of measurement of intraocular pressure by ICARE PRO® tonometer and Goldman applanation tonometer].
    Hladíková E; Pluháček F; Marešová K
    Cesk Slov Oftalmol; 2014 Jun; 70(3):90-3. PubMed ID: 25032793
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Postural change in intraocular pressure: a comparison of measurement with a Goldmann tonometer, Tonopen XL, pneumatonometer, and HA-2.
    Barkana Y
    J Glaucoma; 2014 Jan; 23(1):e23-8. PubMed ID: 24370809
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare
    Valero B; Fénolland JR; Rosenberg R; Sendon D; Mesnard C; Sigaux M; Giraud JM; Renard JP
    J Fr Ophtalmol; 2017 Dec; 40(10):865-875. PubMed ID: 29174296
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma.
    Reznicek L; Muth D; Kampik A; Neubauer AS; Hirneiss C
    Br J Ophthalmol; 2013 Nov; 97(11):1410-4. PubMed ID: 23969314
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rebound tonometer: ideal tonometer for measurement of accurate intraocular pressure.
    Suman S; Agrawal A; Pal VK; Pratap VB
    J Glaucoma; 2014 Dec; 23(9):633-7. PubMed ID: 23429611
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of hemodialysis on intraocular pressure and ocular perfusion pressure.
    Hu J; Bui KM; Patel KH; Kim H; Arruda JA; Wilensky JT; Vajaranant TS
    JAMA Ophthalmol; 2013 Dec; 131(12):1525-31. PubMed ID: 24232671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes].
    Deuter CM; Schlote T; Hahn GA; Bende T; Derse M
    Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.