These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 7271524)

  • 1. Are the Jarvik artificial ventricles limited by inflow resistance?
    Lioi AP; Nielsen SD; Olsen DB
    Artif Organs; 1981 May; 5(2):118-24. PubMed ID: 7271524
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro flow characteristics of the Jarvik-7 prosthesis with respect to filling pressure, stroke frequency, and systolic duration.
    Liska J; Semb BK
    Eur J Cardiothorac Surg; 1989; 3(6):515-20. PubMed ID: 2635938
    [TBL] [Abstract][Full Text] [Related]  

  • 3. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.
    Pelletier B; Spiliopoulos S; Finocchiaro T; Graef F; Kuipers K; Laumen M; Guersoy D; Steinseifer U; Koerfer R; Tenderich G
    Eur J Cardiothorac Surg; 2015 Jan; 47(1):80-6. PubMed ID: 25234093
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Diastolic filling of the heart ventricle].
    Astaf'ev VI; Kuznetsov NP; Kuril'skaia TE; Kuril'skiĭ KA
    Kardiologiia; 1983 Jul; 23(7):82-6. PubMed ID: 6620820
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Concept of a soft, compressible artificial ventricle under evaluation.
    Smulders YM; Tieleman RG; Topaz SR; Bishop ND; Yu LS; Yuan B; Kolff WJ
    Artif Organs; 1991 Apr; 15(2):96-102. PubMed ID: 2036068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic characteristics of the Jarvik-7 total artificial heart.
    Kawaguchi A; Muneretto C; Pavie A; Solis E; Leger P; Gandjbakhch I; Bors V; Desruennes M; Cabrol A; Cabrol C
    Circulation; 1989 Nov; 80(5 Pt 2):III152-7. PubMed ID: 2805296
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A seven-month survival of a calf with an artificial heart designed for human use.
    Mochizuki T; Lawson JH; Olsen DB; Fukumasu H; Daitoh N; Jarvik R; Kessler TR; Pons AB; Hastings L; Razzeca KJ; Nielsen SD; Kolff WJ
    Artif Organs; 1981 May; 5(2):125-31. PubMed ID: 7271525
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of smaller artificial ventricles and valves made by vacuum forming.
    Pantalos GM; Chaing BY; Bishop DN; Perkins PA; Yu LS; Jansen J; Socha PA; Marks JD; Riebman JB; Burns GL
    Int J Artif Organs; 1988 Sep; 11(5):373-80. PubMed ID: 3192315
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Survival for 18 days with a Jarvik-type artificial heart.
    Oster H; Olsen DB; Jarvik R; Stanley TH; Volder JG; Kolff WJ
    Surgery; 1975 Jan; 77(1):113-7. PubMed ID: 122798
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Artificial heart driven by an automatic driving system.
    Unger F; Deutsch M; Eckersberger F; Losert U; Stellwag F; Thoma H; Wolner E; Polzer K; Navratil J
    Med Instrum; 1977; 11(4):208-11. PubMed ID: 895594
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Design and haemodynamic evaluation of the ellipsoid heart for total heart replacement].
    Unger F
    Wien Klin Wochenschr Suppl; 1977; 65():1-17. PubMed ID: 264718
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Role of left ventricular relaxation on transmitral flow dynamics during early diastole: pulsed Doppler flowmetry].
    Tanouchi J; Kitabatake A; Asao M; Morita T; Masuyama T; Hori M; Inoue M; Abe H
    J Cardiogr; 1983 Jun; 13(2):301-7. PubMed ID: 6233381
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A cardiac output monitor and diagnostic unit for pneumatically driven artificial hearts.
    Willshaw P; Nielsen SD; Nanas J; Pichel RH; Olsen DB
    Artif Organs; 1984 May; 8(2):215-9. PubMed ID: 6233957
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative evaluation of artificial ventricles in the United States.
    Peters JL; Greenhalgh SR; Foote JL; Militano TC; Kolff WJ
    Biomater Med Devices Artif Organs; 1975; 3(1):1-24. PubMed ID: 1095090
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow visualization techniques in a mock ventricle supported by a nonpulsatile left ventricular assist device.
    Khalil HA; Metcalfe RW; Kleis SJ; Lee EL; Gilbert NL; Kerr DT; Frazier OH; Cohn WE
    ASAIO J; 2009; 55(4):323-7. PubMed ID: 19512887
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Left ventricular diastolic filling alterations in subjects with mitral valve prolapse: a Doppler echocardiographic study.
    Corrao S; Scaglione R; Arnone S; Licata G
    Eur Heart J; 1993 Mar; 14(3):369-72. PubMed ID: 8458357
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Diastolic left ventricular pressure-mitral valve flow velocity curve: influence of heart rate change induced by atrial pacing].
    Nakaya S; Arakaki Y; Tomita H; Takeuchi N; Kamiya T
    J Cardiogr; 1986 Jun; 16(2):407-16. PubMed ID: 2953824
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differential responses in left ventricular diastolic filling dynamics with isometric handgrip versus isotonic treadmill exertion.
    Mizushige K; Matsuo H; Nozaki S; Kwan OL; DeMaria AN
    Am Heart J; 1996 Jan; 131(1):131-7. PubMed ID: 8553999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immediate effects of diastolic loading variations on the left ventricular inotropic state in open chest dogs.
    Schiereck P; Kil PJ; de Beer EL
    Cardiovasc Res; 1986 May; 20(5):337-48. PubMed ID: 3756975
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increased left ventricular mass is not associated with impaired left ventricular diastolic filling in normal individuals.
    Deague JA; Wilson CM; Grigg LE; Harrap SB
    J Hypertens; 2000 Jun; 18(6):757-62. PubMed ID: 10872561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.