These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 7272407)

  • 1. Histopathologic observations after short-term implantation of two porous elastomers in dogs.
    White RA; Hirose FM; Sproat RW; Lawrence RS; Nelson RJ
    Biomaterials; 1981 Jul; 2(3):171-6. PubMed ID: 7272407
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo comparison of replamineform, Silastic, and bioelectric polyurethane arterial grafts.
    Hiratzka LF; Goeken JA; White RA; Wright CB
    Arch Surg; 1979 Jun; 114(6):698-702. PubMed ID: 454153
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of healing on small internal diameter arterial graft compliance.
    White R; Goldberg L; Hirose F; Klein S; Bosco P; Miranda R; Long J; Nelson R; Shors E
    Biomater Med Devices Artif Organs; 1983; 11(1):21-9. PubMed ID: 6615993
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microtopography and soft tissue response.
    Campbell CE; von Recum AF
    J Invest Surg; 1989; 2(1):51-74. PubMed ID: 2487399
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of pore size on the peel strength of attachment of fibrous tissue to porous-surfaced implants.
    Bobyn JD; Wilson GJ; MacGregor DC; Pilliar RM; Weatherly GC
    J Biomed Mater Res; 1982 Sep; 16(5):571-84. PubMed ID: 7130213
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Study of soft tissue ingrowth into canine porous coated femoral implants designed for osteosarcomas management.
    LaBerge M; Bobyn JD; Rivard CH; Drouin G; Duval P
    J Biomed Mater Res; 1990 Jul; 24(7):959-71. PubMed ID: 2398080
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biofunctionalization of silicone rubber with microgroove-patterned surface and carbon-ion implantation to enhance biocompatibility and reduce capsule formation.
    Lei ZY; Liu T; Li WJ; Shi XH; Fan DL
    Int J Nanomedicine; 2016; 11():5563-5572. PubMed ID: 27822035
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Preliminary report: Evaluation of tissue ingrowth into experimental Replamineform vascular prostheses.
    White RA; White EW; Hanson EL; Rohner RF; Webb WR
    Surgery; 1976 Feb; 79(02):229-32. PubMed ID: 1246679
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vivo method to evaluate the effect of materials upon arterial thrombosis.
    Van Kampen CL; Jones RD; Gibbons DF
    Biomater Med Devices Artif Organs; 1978; 6(1):37-56. PubMed ID: 656536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interface mechanics of porous titanium implants.
    Clemow AJ; Weinstein AM; Klawitter JJ; Koeneman J; Anderson J
    J Biomed Mater Res; 1981 Jan; 15(1):73-82. PubMed ID: 7348706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone.
    Bobyn JD; Pilliar RM; Cameron HU; Weatherly GC
    Clin Orthop Relat Res; 1980; (150):263-70. PubMed ID: 7428231
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Polyurethane or silicone as long-term implant substance--a critical evaluation].
    Behrend D; Schmitz KP
    Biomed Tech (Berl); 1993; 38(7-8):172-8. PubMed ID: 8400014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of polymer-coated balloon-expandable stents in bile ducts.
    Alvarado R; Palmaz JC; Garcia OJ; Tio FO; Rees CR
    Radiology; 1989 Mar; 170(3 Pt 2):975-8. PubMed ID: 2916065
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patency and durability of small diameter silicone rubber vascular prostheses.
    Stimpson C; White R; Klein S; Shors E
    Biomater Artif Cells Artif Organs; 1989; 17(1):31-43. PubMed ID: 2775867
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An animal study of a newly developed skin-penetrating pad and covering material for catheters to prevent exit-site infection in continuous ambulatory peritoneal dialysis.
    Aoyama M; Mizuno T; Tatsumi E; Taenaka Y; Nemoto Y; Okamoto Y; Takemoto Y; Naganuma T; Nakatani T
    Artif Organs; 2009 Dec; 33(12):1127-33. PubMed ID: 19604229
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of silicone/polyurethane graft polymers as a means of eliminating surface cracking of polyurethane prostheses.
    Pinchuk L; Martin JB; Esquivel MC; MacGregor DC
    J Biomater Appl; 1988 Oct; 3(2):260-96. PubMed ID: 3204496
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanical and biological evaluations of beta-tricalcium phosphate/silicone rubber composite as a novel soft-tissue implant.
    Zhang YM; Wang SL; Lei ZY; Fan DL
    Aesthetic Plast Surg; 2009 Sep; 33(5):760-9. PubMed ID: 19452200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental study of osteogenic activity of sintered hydroxyapatite--on the relationship of sintering temperature and pore size.
    Wang FR
    Nihon Seikeigeka Gakkai Zasshi; 1990 Sep; 64(9):847-59. PubMed ID: 2230433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of porous polyethylene for external ear reconstruction.
    Shanbhag A; Friedman HI; Augustine J; von Recum AF
    Ann Plast Surg; 1990 Jan; 24(1):32-9. PubMed ID: 2301880
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface microarchitectural design in biomedical applications: in vivo analysis of tissue ingrowth in excimer laser-directed micropored scaffold for cardiovascular tissue engineering.
    Nakayama Y; Nishi S; Ishibashi-Ueda H; Matsuda T
    J Biomed Mater Res; 2000 Sep; 51(3):520-8. PubMed ID: 10880097
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.