These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 7274292)

  • 1. Application of x-ray fluorescence to the study of iodine distribution and content in the thyroid.
    Aubert B; Fragu P; Di Paola M; Rougier P; Tubiana M
    Eur J Nucl Med; 1981; 6(9):407-10. PubMed ID: 7274292
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Iodine content and distribution in extratumoral and tumor thyroid tissue analyzed with X-ray fluorescence and time-of-flight secondary ion mass spectrometry.
    Hansson M; Grunditz T; Isaksson M; Jansson S; Lausmaa J; Mölne J; Berg G
    Thyroid; 2008 Nov; 18(11):1215-20. PubMed ID: 19014328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-situ x-ray fluorescence imaging of the endogenous iodine distribution in murine thyroids.
    Körnig C; Staufer T; Schmutzler O; Bedke T; Machicote A; Liu B; Liu Y; Gargioni E; Feliu N; Parak WJ; Huber S; Grüner F
    Sci Rep; 2022 Feb; 12(1):2903. PubMed ID: 35190621
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [In vivo X-ray fluorescent analysis of iodine concentration in the thyroid (author's transl)].
    Imamura K; Sasaki Y; Uji T; Someya K; Fujii M
    Radioisotopes; 1977 Dec; 26(12):858-63. PubMed ID: 605222
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radioactive implant induced x-ray emission technique for noninvasive determination of iodine content in thyroid: experimental study.
    Amano R; Tonami N; Ando A; Hiraki T; Hisada K
    Int J Appl Radiat Isot; 1984 Feb; 35(2):123-7. PubMed ID: 6706428
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous emission and fluorescent scanning of the thyroid.
    Patton JA; Brill AB
    J Nucl Med; 1978 May; 19(5):464-9. PubMed ID: 641567
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Thallium-201 radioactive implant induced X-ray emission scanning of stable iodine distribution in thyroid--phantom experiment.
    Amano R; Ando A; Hiraki T; Tonami N; Hisada K
    Radioisotopes; 1986 May; 35(5):266-9. PubMed ID: 3489251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The in vivo measurement of the total iodine content of the thyroid gland by x-ray fluorescence.
    Gollnick DA; Greenfield MA
    Radiology; 1978 Jan; 126(1):197-200. PubMed ID: 619407
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Potentials of in vivo x-ray fluorescence analysis].
    Tomashevskiĭ IO
    Med Radiol (Mosk); 1984 Apr; 29(4):64-8. PubMed ID: 6717268
    [No Abstract]   [Full Text] [Related]  

  • 10. [Direct evaluation of thyroid I-127 in an iodine overload situation: in vivo study by X-ray fluorescence and in vitro by analytical ion microscopy].
    Briançon C; Jeusset J; Halpern S; Fragu P
    Ann Endocrinol (Paris); 1992; 53(5-6):178-86. PubMed ID: 1340684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical usefulness of thyroid imaging by means of X-ray fluorescence.
    Jonckheer MH
    Horm Res; 1987; 26(1-4):42-7. PubMed ID: 3297963
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evolution of thyroid 127I stores measured by X-ray fluorescence in subacute thyroiditis.
    Fragu P; Rougier P; Schlumberger M; Tubiana M
    J Clin Endocrinol Metab; 1982 Jan; 54(1):162-6. PubMed ID: 7054213
    [TBL] [Abstract][Full Text] [Related]  

  • 13. X-ray fluorescence analysis (XFA) of thyroidal iodine content (TIC) with an improved measuring system.
    Reiners C; Hänscheid H; Lassmann M; Tiemann M; Kreissl M; Rendl J; Bier D
    Exp Clin Endocrinol Diabetes; 1998; 106 Suppl 3():S31-3. PubMed ID: 9865551
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Roentgen ray fluorescence method for determination of iodine in tissue.
    Puumalainen P; Lahtinen T
    Acta Radiol Ther Phys Biol; 1977 Dec; 16(6):529-37. PubMed ID: 607782
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fluorescent thyroid scanning. A method based on stable iodine measurements.
    Wahner HW; Sweet RA; McConahey WM; Duick DS
    Mayo Clin Proc; 1978 Mar; 53(3):151-6. PubMed ID: 628225
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative thyroid fluorescent scanning: technique and clinical experience.
    Thrall JH; Gillen MT; Johnson MC; Corcoran RJ; Wartofsky L
    AJR Am J Roentgenol; 1978 Mar; 130(3):517-22. PubMed ID: 415561
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A new in vivo radiation method for determining the stable iodine content of the thyroid].
    Tomashevskiĭ IO; Tomashevskiĭ DI
    Med Radiol (Mosk); 1991; 36(3):19-22. PubMed ID: 2016999
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.
    Ren L; Wu D; Li Y; Wang G; Wu X; Liu H
    Med Phys; 2014 Mar; 41(3):031902. PubMed ID: 24593720
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vivo measurement of absolute tissue iodine content by fluorescence excitation.
    Olkkonen H; Webber CE; Sikanen P; Puumalainen P
    Invest Radiol; 1979; 14(3):246-9. PubMed ID: 468498
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Iontophoresis: mechanism of action studied by potentiometry and x-ray fluorescence.
    Puttemans FJ; Massart DL; Gilles F; Lievens PC; Jonckeer MH
    Arch Phys Med Rehabil; 1982 Apr; 63(4):176-80. PubMed ID: 7082142
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.