BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 7275540)

  • 1. Photographic unsharp masking in chest radiography.
    Sorenson JA; Niklason LT; Nelson JA
    Invest Radiol; 1981; 16(4):281-8. PubMed ID: 7275540
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of optical unsharp masking and contrast enhancement of low-scatter chest radiographs.
    Sorenson JA; Mitchell CR
    AJR Am J Roentgenol; 1987 Aug; 149(2):275-81. PubMed ID: 3496751
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Evaluation of an automated adaptive unsharp masking technique in digital chest radiographs].
    Abe K; Katsuragawa S; Sasaki Y
    Nihon Igaku Hoshasen Gakkai Zasshi; 1992 Feb; 52(2):164-71. PubMed ID: 1561056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A fully automated adaptive unsharp masking technique in digital chest radiograph.
    Abe K; Katsuragawa S; Sasaki Y; Yanagisawa T
    Invest Radiol; 1992 Jan; 27(1):64-70. PubMed ID: 1733884
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical evaluation of unsharp masking and slit scanning techniques in chest radiography.
    Armstrong JD; Sorenson JA; Nelson JA; Tocino I; Lester PD; Janes JO; Niklason LT; Stanish W
    Radiology; 1983 May; 147(2):351-6. PubMed ID: 6340155
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.
    Kimme-Smith C; Aberle DR; Sayre JW; Hart EM; Greaves SM; Brown K; Young DA; Deseran MD; Johnson T; Johnson SL
    AJR Am J Roentgenol; 1995 Aug; 165(2):269-73. PubMed ID: 7618538
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved parameters for unsharp mask filtering of digital chest radiographs.
    Prokop M; Schaefer CM; Oestmann JW; Galanski M
    Radiology; 1993 May; 187(2):521-6. PubMed ID: 8475301
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of improved contrast on lung-nodule detection. A clinical ROC study.
    Sorenson JA; Mitchell CR; Armstrong JD; Mann H; Bragg DG; Mann FA; Tocino IB; Wojtowycz MM
    Invest Radiol; 1987 Oct; 22(10):772-80. PubMed ID: 3429172
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Simulation of lung nodules for nodule detection studies.
    Sorenson JA; Nelson JA; Niklason LA; Klauber MR
    Invest Radiol; 1980; 15(6):490-5. PubMed ID: 7203903
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Digital beam attenuator technique for compensated chest radiography.
    Hasegawa BH; Naimuddin S; Dobbins JT; Mistretta CA; Peppler WW; Hangiandreou NJ; Cusma JT; McDermott JC; Kudva BV; Melbye KM
    Radiology; 1986 May; 159(2):537-43. PubMed ID: 3961188
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Film-based chest radiography: AMBER vs asymmetric screen-film systems.
    Chotas HG; Floyd CE; Ravin CE
    AJR Am J Roentgenol; 1993 Oct; 161(4):743-7. PubMed ID: 8372749
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rotating disk device for slit radiography of the chest.
    Sorenson JA; Nelson JA; Niklason LT; Jacobsen SC
    Radiology; 1980 Jan; 134(1):227-31. PubMed ID: 7350609
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Investigation of basic imaging properties in digital radiography. 4. Effect of unsharp masking on the detectability of simple patterns.
    Loo LN; Doi K; Metz CE
    Med Phys; 1985; 12(2):209-14. PubMed ID: 4000078
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The significance of efficient scatter removal in chest radiography.
    Herrera M; Moore R; Justich E; Castaneda-Zuniga WR; Amplatz K
    Rofo; 1982 Dec; 137(6):711-7. PubMed ID: 6218052
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of simulated chest lesions: comparison of a conventional screen-film combination, an asymmetric screen-film system, and storage phosphor radiography.
    Leppert AG; Prokop M; Schaefer-Prokop CM; Galanski M
    Radiology; 1995 Apr; 195(1):259-63. PubMed ID: 7892482
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Support line and tube visibility in chest examinations using computed radiography.
    Huda W; Belden CJ; Webb LA; Palmer CK
    J Digit Imaging; 1997 Aug; 10(3):126-31. PubMed ID: 9268908
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A scanning equalization system for improved chest radiography.
    Plewes DB; Wandtke JC
    Radiology; 1982 Mar; 142(3):765-8. PubMed ID: 7063700
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blurred-mask density compression for improved reproduction of radiographs.
    Bednarek DR; Rudin S
    Invest Radiol; 1991 Apr; 26(4):358-63. PubMed ID: 2032824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a digital duplication system for portable chest radiographs.
    Hoffmann KR; Doi K; MacMahon H; Giger ML; Nishikawa RM; Xu XW; Yao L; Kano A; Carlin M
    J Digit Imaging; 1994 Aug; 7(3):146-53. PubMed ID: 7948174
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of imaging properties of a computed radiography system and screen-film systems.
    Sanada S; Doi K; Xu XW; Yin FF; Giger ML; MacMahon H
    Med Phys; 1991; 18(3):414-20. PubMed ID: 1870484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.