These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 7293705)

  • 1. Admixture of atmospheric air in the T-piece used as a weaning system.
    Hartmann-Andersen F; Andersen PK; Olsen JE
    Acta Anaesthesiol Scand; 1981 Feb; 25(1):63-6. PubMed ID: 7293705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Distribution of expiratory gas and rebreathing in T-piece modifications used in weaning.
    Hartmann-Andersen F; Andersen PK; Olsen JE; Jakubaszko J
    Acta Anaesthesiol Scand; 1983 Dec; 27(6):501-4. PubMed ID: 6421079
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distribution of expiratory gas and rebreathing in a T-piece modification combined with a PEEP valve.
    Hartmann-Andersen F; Andersen PK; Olsen JE; Jakubaszko J
    Acta Anaesthesiol Scand; 1984 Dec; 28(6):671-6. PubMed ID: 6441434
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Monitoring tidal volumes when using the Ventrain® emergency ventilator].
    Schmidt AR; Ruetzler K; Haas T; Schmitz A; Weiss M
    Anaesthesist; 2016 Jul; 65(7):514-20. PubMed ID: 27245923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rebreathing in a T-piece: volunteer and theoretical studies of the Jackson-Rees modification of Ayre's T-piece during spontaneous respiration.
    Willis BA; Pender JW; Mapleson WW
    Br J Anaesth; 1975 Dec; 47(12):1239-46. PubMed ID: 1218161
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A laboratory evaluation of 2 mechanical ventilators in the presence of helium-oxygen mixtures.
    Brown MK; Willms DC
    Respir Care; 2005 Mar; 50(3):354-60. PubMed ID: 15737245
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Maximizing oxygen delivery during mechanical ventilation with a portable oxygen concentrator.
    Rodriquez D; Blakeman TC; Dorlac W; Johannigman JA; Branson RD
    J Trauma; 2010 Jul; 69 Suppl 1():S87-93. PubMed ID: 20622626
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modified interface between pediatric ventilator and Ayre's T-piece for use in neonates.
    el-Attar AM
    Middle East J Anaesthesiol; 1996 Feb; 13(4):395-403. PubMed ID: 8713634
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation.
    Vallverdú I; Calaf N; Subirana M; Net A; Benito S; Mancebo J
    Am J Respir Crit Care Med; 1998 Dec; 158(6):1855-62. PubMed ID: 9847278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Respiratory drive and breathing pattern during exercise in man.
    Lind FG
    Acta Physiol Scand Suppl; 1984; 533():1-47. PubMed ID: 6594031
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of displayed values of tidal volume in the pediatric intensive care unit.
    Castle RA; Dunne CJ; Mok Q; Wade AM; Stocks J
    Crit Care Med; 2002 Nov; 30(11):2566-74. PubMed ID: 12441771
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Alterations in peak inspiratory pressure and tidal volume delivered by manually operated self-inflating resuscitation bags as a function of the oxygen supply rate.
    Godoy AC; Vieira RJ; De Capitani EM
    J Bras Pneumol; 2008 Oct; 34(10):817-21. PubMed ID: 19009215
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic ventilation with the Ayre's T-piece. A modification of the Nuffield Series 200 ventilator for neonatal and paediatric use.
    Newton NI; Hillman KM; Varley JG
    Anaesthesia; 1981 Jan; 36(1):22-36. PubMed ID: 6937150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation.
    Bien MY; Shui Lin Y; Shih CH; Yang YL; Lin HW; Bai KJ; Wang JH; Ru Kou Y
    Crit Care Med; 2011 Oct; 39(10):2253-62. PubMed ID: 21666447
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision.
    Roehr CC; Kelm M; Fischer HS; Bührer C; Schmalisch G; Proquitté H
    Resuscitation; 2010 Feb; 81(2):202-5. PubMed ID: 19926383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple VD/VT gas-collection valve for use with Siemens ventilators.
    Ritz R; Crogan S
    Respir Care; 1986 Nov; 31(11):1096-8. PubMed ID: 10315716
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantification of the jet function of a jet stylet.
    Gaughan SD; Benumof JL; Ozaki GT
    Anesth Analg; 1992 Apr; 74(4):580-5. PubMed ID: 1554126
    [TBL] [Abstract][Full Text] [Related]  

  • 19. T-piece gas flow palpation as a clinical indicator of endotracheal intubation in neonates.
    Moran PM; Hawkes CP; Dempsey EM; Ryan CA
    Eur J Pediatr; 2013 Apr; 172(4):509-12. PubMed ID: 23271493
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing the length of the expiratory limb of the Ayre's T-piece: implications for remote mechanical ventilation in infants and young children.
    Jackson E; Tan S; Yarwood G; Sury MR
    Br J Anaesth; 1994 Aug; 73(2):154-6. PubMed ID: 7917727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.