These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 730331)

  • 1. The comparison of steel and titanium dynamic compression plates used for internal fixation of 256 fractures of the tibia.
    Holzach P; Matter P
    Injury; 1978 Nov; 10(2):120-3. PubMed ID: 730331
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tibial shaft fractures. A comparison of conservative treatment and internal fixation with conventional plates or AO compression plates.
    Jensen JS; Hansen FW; Johansen J
    Acta Orthop Scand; 1977; 48(2):204-12. PubMed ID: 868506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.
    Jain R; Podworny N; Hearn T; Anderson GI; Schemitsch EH
    J Orthop Trauma; 1997 Oct; 11(7):490-5. PubMed ID: 9334950
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. An experimental study in dogs.
    Uhthoff HK; Bardos DI; Liskova-Kiar M
    J Bone Joint Surg Br; 1981; 63-B(3):427-84. PubMed ID: 7263759
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Elastic stable intramedullary nailing (ESIN) in paediatric femur and tibia shaft fractures: Comparison between titanium and stainless steel nails.
    Marengo L; Nasto LA; Michelis MB; Boero S
    Injury; 2018 Nov; 49 Suppl 3():S8-S11. PubMed ID: 30415674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression.
    Marshall T; Momaya A; Eberhardt A; Chaudhari N; Hunt TR
    J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?
    Kutzler M; Patterson JT; Anz H; Siahaan J; Warner SJ; Gary JL
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2147-2153. PubMed ID: 38564013
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally invasive treatment of distal tibial fractures with locking and non-locking plates.
    Ozkaya U; Parmaksizoglu AS; Gul M; Sokucu S; Kabukcuoglu Y
    Foot Ankle Int; 2009 Dec; 30(12):1161-7. PubMed ID: 20003874
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experience with the dynamic compression plate (DCP) in 418 recent fractures of the tibial shaft.
    Rüedi T; Webb JK; Allgöwer M
    Injury; 1976 May; 7(4):252-7. PubMed ID: 1278983
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Results of treating 221 tibial osteosynthesis with narrow dynamic compression plates (DCP) of steel or titanium (author's transl)].
    Matter P; Holzach P
    Unfallheilkunde; 1977 May; 80(5):195-6. PubMed ID: 867596
    [No Abstract]   [Full Text] [Related]  

  • 11. A biomechanical evaluation of different plates for fixation of canine radial osteotomies.
    Jain R; Podworny N; Hearn T; Richards RR; Schemitsch EH
    J Trauma; 1998 Jan; 44(1):193-7. PubMed ID: 9464772
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Experiences with the dynamic compression plate (DCP) in 418 fresh fractures of the tibial shaft (author's transl)].
    Rüedi T; Kolbow H; Allgöwer M
    Arch Orthop Unfallchir; 1975 Jun; 82(3):247-56. PubMed ID: 1167124
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tibial shaft fractures. The frequency of local complications in tibial shaft fractures treated by internal compression osteosynthesis.
    Kristensen KD
    Acta Orthop Scand; 1979 Oct; 50(5):593-8. PubMed ID: 525327
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial.
    Gyaneshwar T; Nitesh R; Sagar T; Pranav K; Rustagi N
    Chin J Traumatol; 2016 Aug; 19(4):213-6. PubMed ID: 27578377
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Biomechanic study on length of plate in treatment of tibial shaft fracture].
    Hu X; Yang S; Xiao D; Lin B; Wang H; Xu Z; Zhao W; Zhang M
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Nov; 22(11):1323-6. PubMed ID: 19068599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A metallurgical examination of fractured stainless-steel ASIF tibial plates.
    Richman MH; Weltman JK; Cole A
    Injury; 1976 Aug; 8(1):13-9. PubMed ID: 1002271
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Bone remodeling after internal fixation with different stiffness plates: ultrastructural investigation].
    Chen YQ
    Zhonghua Wai Ke Za Zhi; 1991 Apr; 29(4):256-9, 272. PubMed ID: 1874119
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Moore I postero-medial articular tibial fracture in alpine skiers: Surgical management and return to sports activity.
    Morin V; Pailhé R; Sharma A; Rouchy RC; Cognault J; Rubens-Duval B; Saragaglia D
    Injury; 2016 Jun; 47(6):1282-7. PubMed ID: 27037028
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of Bone-Plate Material on the Predicted Stresses in the Tibial Shaft Comminuted Fractures: A Finite Element Analysis.
    Zhou K; Yang H
    J Invest Surg; 2022 Jan; 35(1):132-140. PubMed ID: 33089722
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.