These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 7322085)

  • 1. Improved method for the design of tissue compensators.
    Shragge PC; Patterson MS
    Med Phys; 1981; 8(6):885-91. PubMed ID: 7322085
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An algorithm for design of beam compensators.
    Renner WD; O'Connor TP; Bermudez NM
    Int J Radiat Oncol Biol Phys; 1989 Jul; 17(1):227-34. PubMed ID: 2745197
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Missing tissue compensators: evaluation and optimization of a commercial system.
    Ansbacher W; Robinson DM; Scrimger JW
    Med Phys; 1992; 19(5):1267-72. PubMed ID: 1435608
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose calculations for arbitrarily shaped electron beams.
    Bruinvis IA; van Amstel A; Elevelt AJ; van der Laarse R
    Acta Radiol Suppl; 1983; 364():73-9. PubMed ID: 6316744
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inclusion of compensator-induced scatter and beam filtration in pencil beam dose calculations.
    du Plessis FC; Willemse CA
    Med Phys; 2006 Aug; 33(8):2896-904. PubMed ID: 16964866
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal design of radiation compensators.
    Djordjevich A; Bonham DJ; Hussein EM; Andrew JW; Hale ME
    Med Phys; 1990; 17(3):397-404. PubMed ID: 2385197
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Final Aperture Superposition Technique applied to fast calculation of electron output factors and depth dose curves.
    Faddegon BA; Villarreal-Barajas JE
    Med Phys; 2005 Nov; 32(11):3286-94. PubMed ID: 16370417
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of compensator used in radiation therapy].
    Lin FJ; Cheng NT; Chen HH; Chen CS; Hsien WL; Leung WM
    Changgeng Yi Xue Za Zhi; 1990 Jun; 13(2):104-17. PubMed ID: 2224603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Patient-specific compensation for Co-60 TBI treatments based on Monte Carlo design: A feasibility study.
    Serban M; Seuntjens J; Roussin E; Alexander A; Tremblay JR; Wierzbicki W
    Phys Med; 2016 Jan; 32(1):67-75. PubMed ID: 26498377
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Compensators for three-dimensional treatment planning.
    Mageras GS; Mohan R; Burman C; Barest GD; Kutcher GJ
    Med Phys; 1991; 18(2):133-40. PubMed ID: 2046597
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preliminary investigations for the option to use fast uniform scanning with compensators on a gantry designed for IMPT.
    Zenklusen SM; Pedroni E; Meer D; Bula C; Safai S
    Med Phys; 2011 Sep; 38(9):5208-16. PubMed ID: 21978065
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A method of correction for curvature and inhomogeneities in computer aided calculation of external beam radiation dose distributions.
    Mohan R; Antich PP
    Comput Programs Biomed; 1979 May; 9(3):247-57. PubMed ID: 436407
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Design, development, and dosage control of individual compensatory filters for 6 MV X-ray radiotherapy].
    Zonca G; Loi G; Somigliana A; Filice S; Crippa M; Manciero S; Stucchi C; Poste D; Sichirollo AE
    Radiol Med; 1995 May; 89(5):695-701. PubMed ID: 7617914
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calculation of dose in off-central axis planes using off-axis ratios.
    Prasad SC; Bassano DA; Ames TE
    Med Phys; 1984; 11(2):204-6. PubMed ID: 6727796
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computer generated scatter dose distributions for 6-MV radiotherapy photon beams.
    Bloch P; Wallace R
    Med Phys; 1979; 6(2):149-52. PubMed ID: 460065
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A microcomputer-based system for radiotherapy beam compensator design and patient contour plotting.
    Andrew JW; Aldrich JE
    Med Phys; 1982; 9(2):279-83. PubMed ID: 7087915
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimized tissue compensators.
    Robinson DM; Scrimger JW
    Med Phys; 1990; 17(3):391-6. PubMed ID: 2385196
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mantle fields in the era of dynamic multileaf collimation: field shaping and electronic tissue compensation.
    Davis QG; Paulino AC; Miller R; Ting JY
    Med Dosim; 2006; 31(3):179-83. PubMed ID: 16905447
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
    Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
    Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calculation of the dose delivered to organs outside the radiation beams.
    Francois P; Beurtheret C; Dutreix A
    Med Phys; 1988; 15(6):879-83. PubMed ID: 3237145
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.