These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

57 related articles for article (PubMed ID: 7323895)

  • 1. [Adjustment of the outline of a humanoid phantom to individual body sections].
    Lehmann W; Leetz HK
    Rontgenpraxis; 1981; 34(12):493-6. PubMed ID: 7323895
    [No Abstract]   [Full Text] [Related]  

  • 2. Canine anatomic phantom for preclinical dosimetry in internal emitter therapy.
    Padilla L; Lee C; Milner R; Shahlaee A; Bolch WE
    J Nucl Med; 2008 Mar; 49(3):446-52. PubMed ID: 18287264
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A rotation phantom for setting and testing the parameters of moving radiation].
    Kirschner H; Kaiser G
    Strahlentherapie; 1984 Jan; 160(1):15-20. PubMed ID: 6701922
    [No Abstract]   [Full Text] [Related]  

  • 4. [Simulation. 2].
    Akazuka T
    Kango Kyoiku; 1982 Feb; 23(2):83-9. PubMed ID: 6918579
    [No Abstract]   [Full Text] [Related]  

  • 5. Simulation methods in medical education.
    Gleeson F
    Ir Med J; 1980 Apr; 73(4):177-9. PubMed ID: 7390746
    [No Abstract]   [Full Text] [Related]  

  • 6. [Automated measurement of relative distribution of depth dose in water phantom (author's transl)].
    Prokes K; Lokajícek M; Franc M; Zahálka T
    Cesk Radiol; 1981 Mar; 35(2):85-90. PubMed ID: 7214597
    [No Abstract]   [Full Text] [Related]  

  • 7. On the need to revise the arm structure in stylized anthropomorphic phantoms in lateral photon irradiation geometry.
    Lee C; Lee C; Lee JK
    Phys Med Biol; 2006 Nov; 51(21):N393-402. PubMed ID: 17047258
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of a radiotherapy stimulator for imaging of body cross sections.
    Webb S; Lillicrap SC; Steere H
    Br J Radiol; 1977 Feb; 50(590):152-3. PubMed ID: 831943
    [No Abstract]   [Full Text] [Related]  

  • 9. Bioman--an improved occupant-crew station compliance modeling system.
    Frisch GD; D'Aulerio LA
    Aviat Space Environ Med; 1980 Feb; 51(2):160-7. PubMed ID: 7362563
    [No Abstract]   [Full Text] [Related]  

  • 10. [Construction of phantom models for teaching and practice purposes using polyurethanes].
    Köhler H; Schaal W
    Zahntechnik (Berl); 1980 Feb; 21(2):52-3. PubMed ID: 6931458
    [No Abstract]   [Full Text] [Related]  

  • 11. Three-dimensional reconstruction of the rat incisor by means of computerized histomorphometry.
    Steigman S; Michaeli Y; Weinreb M; Zajicek G
    Anat Rec; 1983 Apr; 205(4):455-64. PubMed ID: 6344695
    [No Abstract]   [Full Text] [Related]  

  • 12. Radiation dose to laterally transposed ovaries during external beam radiotherapy for cervical cancer.
    Mazonakis M; Damilakis J; Varveris H; Gourtsoyiannis N
    Acta Oncol; 2006; 45(6):702-7. PubMed ID: 16938813
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A device for the automatic recording of patient outlines on the treatment simulator.
    Lillicrap SC; Milan J
    Phys Med Biol; 1975 Jul; 20(4):627-31. PubMed ID: 1187792
    [No Abstract]   [Full Text] [Related]  

  • 14. Three-dimensional reconstruction of brain capillaries from frozen serial sections.
    Wiederhold KH; Bielser W; Schulz U; Veteau MJ; Hunziker O
    Microvasc Res; 1976 Mar; 11(2):175-80. PubMed ID: 1272078
    [No Abstract]   [Full Text] [Related]  

  • 15. Lung correction and mid plane irradiation dose factors in anatomic phantoms of proportional sizes.
    Vrtar M; Schmidt W
    Acta Med Croatica; 1994; 48(1):21-6. PubMed ID: 7519492
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three-dimensional reconstruction from serial sections.
    Ware RW
    Int Rev Cytol; 1975; 40():325-440. PubMed ID: 1097356
    [No Abstract]   [Full Text] [Related]  

  • 17. A computer-aided technique for the generation of a 3-D finite element model of a vertebra.
    Hakim NS; King AI
    Comput Biol Med; 1978; 8(3):187-96. PubMed ID: 710082
    [No Abstract]   [Full Text] [Related]  

  • 18. Individual radiation therapy patient whole-body phantoms for peripheral dose evaluations: method and specific software.
    Alziar I; Bonniaud G; Couanet D; Ruaud JB; Vicente C; Giordana G; Ben-Harrath O; Diaz JC; Grandjean P; Kafrouni H; Chavaudra J; Lefkopoulos D; de Vathaire F; Diallo I
    Phys Med Biol; 2009 Sep; 54(17):N375-83. PubMed ID: 19652292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [A quality assurance program for simulators in radiotherapy. 1: The universal phantom for quality control of therapy simulators and teletherapy equipment].
    Baltas D; Müller-Sievers K; Kober B
    Strahlenther Onkol; 1993 May; 169(5):296-303. PubMed ID: 8503089
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The pi meson therapy program at SIN.
    von Essen CF
    J Can Assoc Radiol; 1980 Mar; 31(1):19-25. PubMed ID: 7364842
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 3.