BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 7328389)

  • 1. Immunoturbidimetric measurement of cold insoluble globulin with reference to a laser nephelometric assay.
    Gressner AM; Wallraff P
    J Clin Chem Clin Biochem; 1981 Dec; 19(12):1213-5. PubMed ID: 7328389
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [The use of laser nephelometry for the determination and computer-assisted calculation of the fibronectin concentration in various body fluids (author's transl)].
    Gressner AM; Wallraff P
    J Clin Chem Clin Biochem; 1980 Nov; 18(11):797-805. PubMed ID: 6777453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a rapid immunoturbidimetric assay for opsonic fibronectin in surgical and trauma patients.
    Saba TM; Albert WH; Blumenstock FA; Evanega G; Staehler F; Cho E
    J Lab Clin Med; 1981 Oct; 98(4):482-91. PubMed ID: 7288265
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid immunochemical determination of plasma fibronectin with a centrifugal analyzer.
    Hamel G; Toazara DJ; Mark J
    Ann Biol Clin (Paris); 1982; 40(6):661-5. PubMed ID: 6819790
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple and rapid nephelometric procedure for fibronectin.
    Cuigniez PH; Biesbrouck M; van Hooren J
    Ann Clin Biochem; 1985 Sep; 22 ( Pt 5)():514-8. PubMed ID: 3933402
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative determination of fibronectin (FN): evaluation of immunoturbidimetric and rate nephelometric techniques for FN assay in the different biologic materials.
    Mangraviti S; Ciprandi G; Rossi G; Famularo L; Bagnasco M; Canonica GW
    Allergol Immunopathol (Madr); 1995; 23(6):285-9. PubMed ID: 8579007
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Assay of plasma fibronectin in clinical biology: comparison of nephelometric and turbidimetric technics].
    North ML; Hérold Y; Piffaut MC; Roos M
    Ann Biol Clin (Paris); 1983; 41(6):351-8. PubMed ID: 6421208
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry.
    Denham E; Mohn B; Tucker L; Lun A; Cleave P; Boswell DR
    Ann Clin Biochem; 2007 Nov; 44(Pt 6):529-36. PubMed ID: 17961307
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Measurement of plasma fibronectin by laser nephelometry].
    Suzuki S; Nakamaru K; Suzuki M; Asami A; Kanayama M
    Rinsho Byori; 1983 Nov; 31(11):1239-43. PubMed ID: 6672297
    [No Abstract]   [Full Text] [Related]  

  • 10. Rapid determination of fibronectin by laser nephelometry. Fibronectin concentrations is plasma in human diseases, I.
    Pott G; Meyering M; Voss B; Karges HE; Sieber A
    J Clin Chem Clin Biochem; 1980 Dec; 18(12):893-5. PubMed ID: 7205147
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microparticle-enhanced nephelometric immunoassay of human plasminogen.
    Marchal E; Montagne P; Cuillière ML; Béné MC; Faure G
    J Clin Lab Anal; 1996; 10(2):85-90. PubMed ID: 8852360
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Laser nephelometric quantitation of fibronectin (cold-insoluble globulin) in human cerebrospinal fluid and seminal plasma.
    Gressner AM; Wallraff P
    Clin Chim Acta; 1981 Jun; 113(2):207-12. PubMed ID: 7249363
    [No Abstract]   [Full Text] [Related]  

  • 13. Evaluation of an improved immunoturbidimetic assay for serum C-reactive protein on a COBAS INTEGRA 400 Analyzer.
    Sánchez A; Mirabel JL; Barrenechea E; Eugui J; Puelles A; Castañeda A
    Clin Lab; 2002; 48(5-6):313-7. PubMed ID: 12071582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rate-nephelometric determination of fibronectin in plasma.
    van Helden WC; Kok-Verspuy A; Harff GA; van Kamp GJ
    Clin Chem; 1985 Jul; 31(7):1182-4. PubMed ID: 3891139
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A turbidimetric method for fibronectin assay in the dog.
    Hauptman JG; Feldman BF; O'Neill SL; Lippert AC; Davis AT
    Am J Vet Res; 1988 Nov; 49(11):1935-6. PubMed ID: 3247918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Four immunoassay methods and standards compared for measuring fibronectin.
    Brubaker DB; Blick KE; Romine M
    Clin Chem; 1987 Jan; 33(1):126-9. PubMed ID: 3542286
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated turbidimetry of serum lipoprotein(a).
    Borque L; Maside C; Iglesias A
    Eur J Clin Chem Clin Biochem; 1993 Dec; 31(12):869-74. PubMed ID: 8136419
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of immunoglobulin A in saliva by particle-enhanced nephelometric immunoassay: sample collection, limits of quantitation, precision, stability and reference range.
    Booth CK; Dwyer DB; Pacque PF; Ball MJ
    Ann Clin Biochem; 2009 Sep; 46(Pt 5):401-6. PubMed ID: 19641004
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid determination of cold insoluble globulin by laser nephelometry. Application in patients receiving preoperative total parenteral nutrition.
    Brodin B; Cederblad G; Larsson J; Schildt B; Sjödahl R; Symreng T; Wetterfors J
    JPEN J Parenter Enteral Nutr; 1982; 6(3):214-7. PubMed ID: 6809977
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance characteristics of an immunoturbidimetric assay for lipoprotein-associated phospholipase A2.
    Rawlins ML; La'ulu SL; Moon N; Roberts WL
    Clin Chim Acta; 2009 Aug; 406(1-2):66-70. PubMed ID: 19463805
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.