These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 7332620)

  • 41. Comparison of endotracheal intubation with the Shikani Optical Stylet using the left molar approach and direct laryngoscopy.
    Yao YT; Jia NG; Li CH; Zhang YJ; Yin YQ
    Chin Med J (Engl); 2008 Jul; 121(14):1324-7. PubMed ID: 18713556
    [No Abstract]   [Full Text] [Related]  

  • 42. Pharyngeal wall injury during videolaryngoscopy-assisted intubation.
    Nestler C; Reske AP; Reske AW; Pethke H; Koch T
    Anesthesiology; 2013 Mar; 118(3):709. PubMed ID: 22801050
    [No Abstract]   [Full Text] [Related]  

  • 43. More trouble with airway definitions.
    Cooper RM
    Anesthesiology; 2007 Jul; 107(1):170; author reply 171. PubMed ID: 17585233
    [No Abstract]   [Full Text] [Related]  

  • 44. [Tongue haematoma after difficult intubation facilitated by the presence of an subclinical tumor].
    Sueur G; Baert O; Rozada P; Rezig N; Dureuil B
    Ann Fr Anesth Reanim; 2009 Sep; 28(9):808-9. PubMed ID: 19695827
    [No Abstract]   [Full Text] [Related]  

  • 45. [Specifics of difficult intubation in children].
    Ecoffey C
    Rev Med Suisse Romande; 1999 Nov; 119(11):887-90. PubMed ID: 10628209
    [No Abstract]   [Full Text] [Related]  

  • 46. Poor visualization during direct laryngoscopy and high upper lip bite test score are predictors of difficult intubation with the GlideScope videolaryngoscope.
    Tremblay MH; Williams S; Robitaille A; Drolet P
    Anesth Analg; 2008 May; 106(5):1495-500, table of contents. PubMed ID: 18420866
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Teeth--and the anesthetist.
    Fisher TL
    Can Med Assoc J; 1972 Mar; 106(5):602-3. PubMed ID: 4402142
    [No Abstract]   [Full Text] [Related]  

  • 48. Nalbuphine prevents haemodynamic response to endotracheal intubation.
    Ahsan-ul-Haq M; Kazmi EH; Rao ZA
    J Coll Physicians Surg Pak; 2005 Nov; 15(11):668-70. PubMed ID: 16300696
    [TBL] [Abstract][Full Text] [Related]  

  • 49. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope.
    Turkstra TP; Jones PM; Ower KM; Gros ML
    Anesth Analg; 2009 Dec; 109(6):1856-9. PubMed ID: 19923515
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients.
    Maassen R; Lee R; Hermans B; Marcus M; van Zundert A
    Anesth Analg; 2009 Nov; 109(5):1560-5. PubMed ID: 19713258
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A comparison of lighted stylet (Surch-Lite) and direct laryngoscopic intubation in patients with high Mallampati scores.
    Rhee KY; Lee JR; Kim J; Park S; Kwon WK; Han S
    Anesth Analg; 2009 Apr; 108(4):1215-9. PubMed ID: 19299790
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Asystole during laryngoscopy of a patient with pleural and pericardial effusions: a case report.
    Geisz-Everson MA; Wren K; Kennedy L
    AANA J; 2008 Feb; 76(1):25-7. PubMed ID: 18323316
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Incident during endotracheal intubation].
    Gosepath J; Peunte-Egido JJ; Tschokl-Heinrichs H
    Anaesthesist; 1967 Apr; 16(4):112-3. PubMed ID: 5591169
    [No Abstract]   [Full Text] [Related]  

  • 54. Etiology of hypertensive crisis during the intraoperative period.
    Trazzi R; Spinazzi A; Massei R; Parma A; Calappi E
    Ann Fr Anesth Reanim; 1989; 8(5):581-4, 541-4. PubMed ID: 2697159
    [No Abstract]   [Full Text] [Related]  

  • 55. Penetrating injury of the soft palate during GlideScope intubation.
    Hsu WT; Hsu SC; Lee YL; Huang JS; Chen CL
    Anesth Analg; 2007 Jun; 104(6):1609-10; discussion 1611. PubMed ID: 17513675
    [No Abstract]   [Full Text] [Related]  

  • 56. An assessment of the ratio of height to thyromental distance compared to thyromental distance as a predictive test for prediction of difficult tracheal intubation in Thai patients.
    Krobbuaban B; Diregpoke S; Kumkeaw S
    J Med Assoc Thai; 2006 May; 89(5):638-42. PubMed ID: 16756049
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Arytenoid subluxation caused by laryngoscopy and intubation.
    Kempen PM
    Anesthesiology; 2000 May; 92(5):1505-7. PubMed ID: 10781311
    [No Abstract]   [Full Text] [Related]  

  • 58. [Cardio-circulatory response to laryngoscopy. Comparative study between Macintosh and McCoy laryngoscopes].
    Castillo J; CastaƱo J; Escolano F; Arilla M
    Rev Esp Anestesiol Reanim; 1996; 43(6):219-21. PubMed ID: 8756238
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Validation of the GlideScope video laryngoscope in pediatric patients.
    Redel A; Karademir F; Schlitterlau A; Frommer M; Scholtz LU; Kranke P; Kehl F; Roewer N; Lange M
    Paediatr Anaesth; 2009 Jul; 19(7):667-71. PubMed ID: 19638111
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Emergency tracheal intubation: complications associated with repeated laryngoscopic attempts.
    Mort TC
    Anesth Analg; 2004 Aug; 99(2):607-13, table of contents. PubMed ID: 15271750
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.