These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 7341028)

  • 1. Three hollow fiber dialyzers.
    Ebben J; Meyer RM; Sheridan AN; Kjellstrand CM
    Clin Exp Dial Apheresis; 1981; 5(4):423-31. PubMed ID: 7341028
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Four new dialyzers.
    Ebben J; Wilson R; Hanna D; Burau M; Kjellstrand C
    J Dial; 1980; 4(4):147-58. PubMed ID: 7204713
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The evaluation and applications of hemodialyzers for pediatric patients.
    Shideman JR; Meyer RM; Streifel AJ; Lynch RE; Mauer SM; Kjellstrand CM
    J Dial; 1978; 2(3):217-33. PubMed ID: 721983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of three dry-sterilized hollow fiber artifical kidneys.
    Streifel A; Ebben J; Sahr C; Meyer R; Shideman J; Lynch R; Kjellstrand C
    J Dial; 1978; 2(4):347-59. PubMed ID: 721990
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of dialyzer geometry on blood coagulation and biocompatibility.
    Lins LE; Boberg U; Jacobson SH; Kjellstrand C; Ljungberg B; Skröder R
    Clin Nephrol; 1993 Nov; 40(5):281-5. PubMed ID: 8281717
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new scintigraphic method to characterize ultrafiltration in hollow fiber dialyzers.
    Ronco C; Brendolan A; Feriani M; Milan M; Conz P; Lupi A; Berto P; Bettini M; La Greca G
    Kidney Int; 1992 May; 41(5):1383-93. PubMed ID: 1614053
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of blood-membrane interactions on solute clearance during hemodialysis.
    Langsdorf LJ; Krankel LG; Zydney AL
    ASAIO J; 1993; 39(3):M767-72. PubMed ID: 7505640
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Solute removal by hollow-fiber dialyzers.
    Clark WR; Rocha E; Ronco C
    Contrib Nephrol; 2007; 158():20-33. PubMed ID: 17684340
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relationship between dialyzer reuse and the presence of anti-N-like antibodies in chronic hemodialysis patients.
    Kaehny WD; Miller GE; White WL
    Kidney Int; 1977 Jul; 12(1):59-65. PubMed ID: 302361
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a new disposable plate dialyzer and the adverse effect of recirculation single pass dialysis on clearance.
    Bierman MH; Easterling RE
    J Dial; 1977; 1(7):653-64. PubMed ID: 608874
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clearance of gentamicin during hemodialysis: comparison of four artificial kidneys.
    Halpren BA; Axline SG; Coplon NS; Brown DM
    J Infect Dis; 1976 Jun; 133(6):627-36. PubMed ID: 932490
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hollow fiber shape alters solute clearances in high flux hemodialyzers.
    Leypoldt JK; Cheung AK; Chirananthavat T; Gilson JF; Kamerath CD; Deeter RB
    ASAIO J; 2003; 49(1):81-7. PubMed ID: 12558312
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Gambro Lundia Major 1.36 m2 disposable parallel plate dialyzer.
    Dziukas LJ; Douglas SM; Carter PM; Campbell DC; Andrews JT; d'Apice AJ; Kincaid-Smith P
    J Dial; 1979; 3(4):309-25. PubMed ID: 263953
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dialyzer reuse following manual reprocessing with a new sterilant, RenNew-D.
    Gagnon R; Adkar V; Kaye M
    Artif Organs; 1987 Apr; 11(2):132-6. PubMed ID: 3593042
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Plate, coil, and hollow-fiber cuprammonium cellulose dialyzers: discrepancy between incidence of anaphylactic reactions and degree of complement activation.
    Daugirdas JT; Potempa LD; Dinh N; Gandhi VC; Ivanovich PT; Ing TS
    Artif Organs; 1987 Apr; 11(2):140-3. PubMed ID: 3593043
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Water permeability of high-flux dialyzer membranes after Renalin reprocessing.
    Labib ME; Murawski J; Tabani Y; Wolff SH; Zydney AL; Funderburk FR; Huang Z; Kapoian T; Sherman RA
    Kidney Int; 2007 Jun; 71(11):1177-80. PubMed ID: 17377505
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of dialyzer geometry on granulocyte and complement activation.
    Schaefer RM; Heidland A; Hörl WH
    Am J Nephrol; 1987; 7(2):121-6. PubMed ID: 3496792
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of bidirectional aluminum transfer across hollow fiber dialyzers.
    Henriquez M; Burnatowska-Hledin MA; Clark MJ; Mayor GH
    Am J Kidney Dis; 1986 Mar; 7(3):217-20. PubMed ID: 3953570
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Formation of Blood Foam in the Air Trap During Hemodialysis Due to Insufficient Automatic Priming of Dialyzers.
    Jonsson P; Lindmark L; Axelsson J; Karlsson L; Lundberg L; Stegmayr B
    Artif Organs; 2018 May; 42(5):533-539. PubMed ID: 29542180
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluid and solute transfer characteristics in a dialyzer with a high-performance membrane.
    Mineshima M
    Contrib Nephrol; 2011; 173():103-109. PubMed ID: 21865782
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.