These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
230 related articles for article (PubMed ID: 7342510)
1. [Hemodynamic parameters determined by impedance cardiography in hyperthyroidism]. Katzberg B; Brauner R; Gerecke U; Bartels D; Tischmeyer M Z Gesamte Inn Med; 1981 Nov; 36(22):877-81. PubMed ID: 7342510 [TBL] [Abstract][Full Text] [Related]
2. [Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index]. Linde M; Ohnhaus EE; Kirch W Z Kardiol; 1989 Mar; 78(3):181-6. PubMed ID: 2652906 [TBL] [Abstract][Full Text] [Related]
3. [Leakage of irrigating solution during transurethral prostatectomy. An impedance cardiography study (author's transl)]. van Deyk K; Harzmann R; Schorer R; Bichler KH Anaesthesist; 1981 Nov; 30(11):549-54. PubMed ID: 7316127 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of myocardial performance during wheelchair ergometer exercise. Wilde SW; Miles DS; Durbin RJ; Sawka MN; Suryaprasad AG; Gotshall RW; Glaser RM Am J Phys Med; 1981 Dec; 60(6):277-91. PubMed ID: 7315952 [TBL] [Abstract][Full Text] [Related]
5. The evaluation of systolic time intervals and impedance cardiogram of neonates. Kagiya A; Echizenya N; Hamada A; Tachizaki T; Satoh S; Saitoh Y Nihon Sanka Fujinka Gakkai Zasshi; 1989 May; 41(5):601-8. PubMed ID: 2754291 [TBL] [Abstract][Full Text] [Related]
6. A comparison of systolic time intervals measured by impedance cardiography and carotid pulse tracing. Mehlsen J; Bonde J; Rehling M; Tangø M; Trap-Jensen J Dan Med Bull; 1990 Feb; 37(1):93-5. PubMed ID: 2311438 [TBL] [Abstract][Full Text] [Related]
7. [Systolic time intervals during increasing left ventricular filling pressure following extracorporeal circulation. A comparative impedance-cardiographical study (author's transl)]. van Deyk K; Seybold-Epting W; Voigt E; Schorer R Anaesthesist; 1981 Nov; 30(11):555-60. PubMed ID: 7316128 [TBL] [Abstract][Full Text] [Related]
8. Myocardial contractility and cardiac filling measured by impedance cardiography in patients with nitroglycerine-induced vasovagal syncope. Mitro P; Hijová E Pacing Clin Electrophysiol; 2006 Jan; 29(1):1-8. PubMed ID: 16441710 [TBL] [Abstract][Full Text] [Related]
9. [Determination of central hemodynamics in dynamic stress using impedance cardiography in comparison to radiocardiography]. Eisenberg BM; Vollmar R; Linss G; Fürst G; Stern L Z Gesamte Inn Med; 1987 May; 42(10):274-6. PubMed ID: 3630272 [TBL] [Abstract][Full Text] [Related]
10. [Comparative evaluation of impedance cardiographic and dye dilution methods in determining hemodynamic indices]. Kaloianova A Vutr Boles; 1981; 20(4):93-8. PubMed ID: 7029910 [TBL] [Abstract][Full Text] [Related]
11. [Comparative evaluation of the cardiac stroke and minute volumes by impedance cardiography and radiocardiography]. Draganov V; Sheĭretova E Vutr Boles; 1980; 19(5):28-33. PubMed ID: 7003918 [TBL] [Abstract][Full Text] [Related]
12. Noninvasive estimation of the end systolic pressure-volume relationship using impedance cardiography. Summers RL J Miss State Med Assoc; 2000 May; 41(5):575-8. PubMed ID: 10932520 [TBL] [Abstract][Full Text] [Related]
14. [Relation of the impedance cardiogram to the course of myocardial contraction]. Eisenberg BM; Linss G; Romaniuk P; Gliech V; Stern L Z Gesamte Inn Med; 1986 May; 41(9):260-3. PubMed ID: 3727649 [TBL] [Abstract][Full Text] [Related]
15. Impedance cardiography in normal children. Barbacki M; Glück A; Sandhage K; Metzner G Cor Vasa; 1981; 23(3):190-6. PubMed ID: 7261598 [TBL] [Abstract][Full Text] [Related]
16. Measurement of the effect of cardiovascular drugs by impedance cardiography in healthy subjects. Lücker PW; Venitz J; Adolph S; Hey B Methods Find Exp Clin Pharmacol; 1986 Jul; 8(7):443-8. PubMed ID: 2876133 [TBL] [Abstract][Full Text] [Related]
17. Prognostic value of hemodynamic findings from impedance cardiography in hypertensive stroke. Ramirez MF; Tibayan RT; Marinas CE; Yamamoto ME; Caguioa EV Am J Hypertens; 2005 Feb; 18(2 Pt 2):65S-72S. PubMed ID: 15752935 [TBL] [Abstract][Full Text] [Related]
18. [Systolic time intervals measurement by electrical plethysmography (author's transl)]. Colin J; Carre R; Amoretti R Anesth Analg (Paris); 1979; 36(9-10):435-8. PubMed ID: 533001 [TBL] [Abstract][Full Text] [Related]
19. The measurement of systolic time intervals. A microprocessor based system for long-term registration of the impedance cardiogram and the systolic time intervals. Arnaudov K; Faust U Med Prog Technol; 1985; 10(4):229-38. PubMed ID: 4033598 [TBL] [Abstract][Full Text] [Related]
20. [Hemodynamic indices assessed by impedance cardiography in patients with the subacute stage of myocardial infarct before and during bicycle ergometry]. Kaloianova A; Tomov I; Khalacheva S Vutr Boles; 1986; 25(1):54-62. PubMed ID: 3716363 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]