These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 7348707)

  • 1. Finite element temperature analysis of a total hip replacement and measurement of PMMA curing temperatures.
    Swenson LW; Schurman DJ; Piziali Rl
    J Biomed Mater Res; 1981 Jan; 15(1):83-96. PubMed ID: 7348707
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the effects of implant materials and designs on thermal necrosis of bone in cemented hip arthroplasty.
    Li C; Kotha S; Mason J
    Biomed Mater Eng; 2003; 13(4):419-28. PubMed ID: 14646056
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A study of intrusion characteristics of low viscosity cement Simplex-P and Palacos cements in a bovine cancellous bone model.
    Rey RM; Paiement GD; McGann WM; Jasty M; Harrigan TP; Burke DW; Harris WH
    Clin Orthop Relat Res; 1987 Feb; (215):272-8. PubMed ID: 3802646
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conduction analysis of cement interface temperature in total knee arthroplasty.
    Fukushima H; Hashimoto Y; Yoshiya S; Kurosaka M; Matsuda M; Kawamura S; Iwatsubo T
    Kobe J Med Sci; 2002 Apr; 48(1-2):63-72. PubMed ID: 12151722
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
    Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
    J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The temperature problem at the bone-acrylic cement interface of the total hip replacement.
    DiPisa JA; Sih GS; Berman AT
    Clin Orthop Relat Res; 1976; (121):95-8. PubMed ID: 991524
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [In vitro studies on various PMMA bone cements: a first comparison of new materials for arthroplasty].
    Kock HJ; Huber FX; Hillmeier J; Jäger R; Volkmann R; Handschin AE; Letsch R; Meeder PJ
    Z Orthop Unfall; 2008; 146(1):108-13. PubMed ID: 18324591
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of temperature and specimen size on the flexural properties of PMMA bone cement.
    Brown SA; Bargar WL
    J Biomed Mater Res; 1984; 18(5):523-36. PubMed ID: 6376514
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cement mantle fatigue failure in total hip replacement: experimental and computational testing.
    Jeffers JR; Browne M; Lennon AB; Prendergast PJ; Taylor M
    J Biomech; 2007; 40(7):1525-33. PubMed ID: 17070816
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of antibiotic impregnation on the fatigue life of Simplex P and Palacos R acrylic bone cements, with and without centrifugation.
    Davies JP; O'Connor DO; Burke DW; Harris WH
    J Biomed Mater Res; 1989 Apr; 23(4):379-97. PubMed ID: 2708414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Gentamicin release from two-solution and powder-liquid poly(methyl methacrylate)-based bone cements by using novel pH method.
    Merkhan IK; Hasenwinkel JM; Gilbert JL
    J Biomed Mater Res A; 2004 Jun; 69(3):577-83. PubMed ID: 15127405
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stiffness optimisation of cement and stem materials in total hip replacement.
    Hedia HS
    Biomed Mater Eng; 2001; 11(1):1-10. PubMed ID: 11281574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of variation of prosthesis size on cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    J Biomed Mater Res; 1994 Sep; 28(9):1055-60. PubMed ID: 7814433
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical prediction and experimental determination of the effect of mold characteristics on temperature and monomer conversion fraction profiles during polymerization of a PMMA-based bone cement.
    Vallo CI
    J Biomed Mater Res; 2002; 63(5):627-42. PubMed ID: 12209910
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cement strain measurement surrounding loose and well-fixed femoral component stems.
    Crowninshield RD; Tolbert JR
    J Biomed Mater Res; 1983 Sep; 17(5):819-28. PubMed ID: 6619178
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant.
    Lee IY; Skinner HB; Keyak JH
    Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of cyclic loading on gentamicin release from acrylic bone cements.
    Hendriks JG; Neut D; Hazenberg JG; Verkerke GJ; van Horn JR; van der Mei HC; Busscher HJ
    J Biomech; 2005 Apr; 38(4):953-7. PubMed ID: 15713316
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro release of antibiotics from commercial PMMA beads and articulating hip spacers.
    Moojen DJ; Hentenaar B; Charles Vogely H; Verbout AJ; Castelein RM; Dhert WJ
    J Arthroplasty; 2008 Dec; 23(8):1152-6. PubMed ID: 18534493
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reinforcement of bone cement around prostheses by pre-coated wire coil: a finite element model study.
    Grosland N; Kim JK; Park JB
    Biomed Mater Eng; 1995; 5(1):29-36. PubMed ID: 7773144
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.