These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 7349947)

  • 1. Infant endotracheal tube resistance: effects of changing length, diameter, and gas density.
    Wall MA
    Crit Care Med; 1980 Jan; 8(1):38-40. PubMed ID: 7349947
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of helium-oxygen mixtures on endotracheal tubes: an in vitro study.
    Gerbeaux P; Gainnier M; Arnal JM; Papazian L; Jean P; Sainty JM
    J Biomech; 2005 Jan; 38(1):33-7. PubMed ID: 15519337
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Relationship of neonatal endotracheal tube size and airway resistance.
    Oca MJ; Becker MA; Dechert RE; Donn SM
    Respir Care; 2002 Sep; 47(9):994-7. PubMed ID: 12188933
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Responses of the respiratory system to changes in gas density at different inspiratory flow rates].
    Breslav IS; Kalacheva El; Konza EA; Kliueva NZ
    Kosm Biol Aviakosm Med; 1980; 14(6):64-7. PubMed ID: 7442119
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The influence of endotracheal tube size on the airway flow resistance and work in infants analyzed using a simulation technique].
    Shimizu Y; Ishida N; Hagiwara K; Azuma M; Nakano M
    Masui; 1989 Aug; 38(8):1030-5. PubMed ID: 2810696
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Down syndrome: analysis of airway size and a guide for appropriate intubation.
    Shott SR
    Laryngoscope; 2000 Apr; 110(4):585-92. PubMed ID: 10764002
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Airway resistance and work of breathing in tracheostomy tubes.
    Mullins JB; Templer JW; Kong J; Davis WE; Hinson J
    Laryngoscope; 1993 Dec; 103(12):1367-72. PubMed ID: 8246657
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Calculation of intratracheal airway pressure in ventilated neonatal piglets with endotracheal tube leaks.
    Nikischin W; Herber-Jonat S; von Bismarck P; Lange M; Grabitz R
    Crit Care Med; 2007 May; 35(5):1383-9. PubMed ID: 17414085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Submaximal exercise with self-contained breathing apparatus: the effects of hyperoxia and inspired gas density.
    Eves ND; Petersen SR; Jones RL
    Aviat Space Environ Med; 2003 Oct; 74(10):1040-7. PubMed ID: 14556564
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gas flow between coaxial tubes: impedance to gas flow in an endotracheal tube increases with a catheter within.
    Magee PT
    Proc Inst Mech Eng H; 2012 Jun; 226(6):491-4. PubMed ID: 22783765
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The extra work of breathing through adult endotracheal tubes.
    Bolder PM; Healy TE; Bolder AR; Beatty PC; Kay B
    Anesth Analg; 1986 Aug; 65(8):853-9. PubMed ID: 3729022
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of a new, ultrathin-walled two-stage twin endotracheal tube and a conventional endotracheal tube in very premature infants with respiratory distress syndrome: a pilot study.
    Parravicini E; Baccarelli A; Wung JT; Kolobow T; Lorenz JM
    Am J Perinatol; 2007 Feb; 24(2):117-22. PubMed ID: 17304419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new endotracheal tube for infants--laboratory and clinical assessment: a preliminary study.
    Stankiewicz B; Darowski M; Glapiński J; Rawicz M; Michnikowski M; Guć M; Kuraszkiewicz B
    Paediatr Anaesth; 2013 May; 23(5):440-5. PubMed ID: 23445272
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Resistance of pediatric and neonatal endotracheal tubes: influence of flow rate, size, and shape.
    Manczur T; Greenough A; Nicholson GP; Rafferty GF
    Crit Care Med; 2000 May; 28(5):1595-8. PubMed ID: 10834718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of respiratory impedance by impulse oscillometry--effects of endotracheal tubes.
    Kuhnle GE; Brandt T; Roth U; Goetz AE; Smith HJ; Peter K
    Res Exp Med (Berl); 2000 Dec; 200(1):17-26. PubMed ID: 11197918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of helium-oxygen mixtures to relieve upper airway obstruction in a pediatric population.
    Grosz AH; Jacobs IN; Cho C; Schears GJ
    Laryngoscope; 2001 Sep; 111(9):1512-4. PubMed ID: 11568598
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Helium-oxygen and conventional mechanical ventilation in the treatment of large airway obstruction and respiratory failure in an infant.
    Sauder RA; Rafferty JF; Bilenki AL; Berkowitz ID
    South Med J; 1991 May; 84(5):646-8. PubMed ID: 2035090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Flow resistance in pediatric oro- and nasotracheal tubes].
    Hachenberg T; Reinhold P; Vigfusson G; Lawin P
    Anasth Intensivther Notfallmed; 1986 Oct; 21(5):266-9. PubMed ID: 3799949
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correction of compliance and resistance altered by endotracheal tube leaks.
    Nikischin W; Lange M
    Pediatr Crit Care Med; 2003 Jul; 4(3):344-52. PubMed ID: 12831418
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 2005 American Heart Association (AHA) guidelines for cardiopulmonary resuscitation (CPR) and emergency cardiovascular care (ECC) of pediatric and neonatal patients: pediatric basic life support.
    American Heart Association
    Pediatrics; 2006 May; 117(5):e989-1004. PubMed ID: 16651298
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.