These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 7350609)

  • 21. A scanning system for chest radiography with regional exposure control: theoretical considerations.
    Plewes DB
    Med Phys; 1983; 10(5):646-54. PubMed ID: 6646070
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mottle on computed radiographs of the chest in pediatric patients.
    Huda W; Slone RM; Belden CJ; Williams JL; Cumming WA; Palmer CK
    Radiology; 1996 Apr; 199(1):249-52. PubMed ID: 8633153
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Comparison of a standard x-ray film with a high-latitude film in thoracic diagnosis].
    Oestmann JW; Hendrickx PH; Rieder P; Geerlings H
    Rontgenblatter; 1986 Jan; 39(1):7-9. PubMed ID: 3952431
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Chest radiography with a shaped filter at 140 kVp: its diagnostic accuracy compared with that of standard radiographs.
    Guilbeau JC; Mazoyer BM; Pruvost P; Verrey B; Grenier P
    AJR Am J Roentgenol; 1988 May; 150(5):1007-10. PubMed ID: 3258700
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Pediatric air-gap chest digital imaging: an experimental study.
    Kuhns LR; Kottamasu SR
    Pediatr Radiol; 1995 Nov; 25 Suppl 1():S199-201. PubMed ID: 8577526
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Constructions of compensating screen of chest radiography and its clinical applications--evaluation of normal anatomical structures].
    Higashida Y; Nakamura I; Fujimura N; Yoshioka S; Sinzato J; Takahashi M
    Nihon Igaku Hoshasen Gakkai Zasshi; 1989 Mar; 49(3):293-9. PubMed ID: 2755794
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Can digital luminescent radiography substitute for conventional x-ray technics in chest radiography?].
    Neufang KF; Krug B; Lorenz R; Steinbrich W
    Rofo; 1990 May; 152(5):501-9. PubMed ID: 2160680
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Digital chest x-rays with a selenium detector: a prospective comparison with a conventional film-screen combination].
    Freund M; Reuter M; Palmié S; Harder E; Hutzelmann A; Heller M
    Rofo; 1997 Feb; 166(2):101-7. PubMed ID: 9116250
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [New analog and digital imaging techniques for chest diagnosis--principles--clinical value--economics].
    Busch HP; Lehmann KJ; Georgi M
    Aktuelle Radiol; 1993 Jan; 3(1):6-13. PubMed ID: 8448232
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Experiences with a new film-screen system in pediatric thoracic radiography].
    Leenen A; Brandt GA; Riebel T; Marciniak H
    Rofo; 1996 Oct; 165(4):349-52. PubMed ID: 8963046
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs.
    Floyd CE; Baker JA; Chotas HG; Delong DM; Ravin CE
    AJR Am J Roentgenol; 1995 Dec; 165(6):1353-8. PubMed ID: 7484562
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Focal film distance in chest radiography.
    Hendry JE
    Radiol Technol; 1997; 69(2):126. PubMed ID: 9397472
    [No Abstract]   [Full Text] [Related]  

  • 33. AMBER: a scanning multiple-beam equalization system for chest radiography.
    Vlasbloem H; Kool LJ
    Radiology; 1988 Oct; 169(1):29-34. PubMed ID: 3420279
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Bedside thoracic radiography: a comparison between 3 different types of grid].
    Ciccotosto C; Storto ML; Guidotti A; Ferrante R; Bonomo L
    Radiol Med; 1994; 87(1-2):127-33. PubMed ID: 8128015
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical evaluation of manual and automatic exposure control techniques in film-based chest radiography.
    Ismailos E; Mastorakou I; Kelekis NL; Papadopoulos KP; Efstathopoulos EP; Panayiotakis G; Kelekis DA
    Br J Radiol; 1996 Jul; 69(823):650-4. PubMed ID: 8696702
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Square chest films revisited: experience with 16 x 16 inch Siemens chest films.
    Langer SS
    AJR Am J Roentgenol; 1982 Dec; 139(6):1242. PubMed ID: 6983287
    [No Abstract]   [Full Text] [Related]  

  • 37. Evaluation of an anatomical compensation filter for chest radiography.
    Manninen H; Rytkönen H; Soimakallio S; Terho EO; Hentunen J
    Br J Radiol; 1986 Nov; 59(707):1087-92. PubMed ID: 3790895
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Improved routine chest radiography with a trough filter.
    Wieder S; Adams PL
    AJR Am J Roentgenol; 1981 Oct; 137(4):695-8. PubMed ID: 6974962
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Scatter fractions in AMBER imaging.
    Chotas HG; Floyd CE; Dobbins JT; Lo JY; Ravin CE
    Radiology; 1990 Dec; 177(3):879-80. PubMed ID: 2244003
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Improvement of bedside chest radiograph quality using a high ratio grid and an electronic angle meter for alignment.
    Korhola O; Bondestam S; Savikurki S; Liuke M; Kivisaari A; Lamminen A; Vehmas T; Vilmi R
    Acta Radiol; 1994 May; 35(3):244-6. PubMed ID: 8192960
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.