These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 7353274)
21. Evaluation of the Kodak Ektachem glucose and urea methods. Clark PM; Kricka LJ; Whitehead TP Ann Clin Biochem; 1980 Nov; 17(6):293-300. PubMed ID: 6782933 [TBL] [Abstract][Full Text] [Related]
22. An evaluation of the performance of the Hycel Mark X discretionary multiphasic analyzer. Winter SD; Skodon SB; Goldberg MH; Barnett RN Am J Clin Pathol; 1971 Oct; 56(4):526-37. PubMed ID: 4107084 [No Abstract] [Full Text] [Related]
23. Glucose in serum and cerebrospinal fluid by direct application of a glucose oxidase method. Ware AG; Marbach EP Clin Chem; 1968 Jun; 14(6):548-54. PubMed ID: 5654642 [No Abstract] [Full Text] [Related]
24. Diazo-based assay for total bilirubin in a coated thin film evaluated. Weiss JS; Sundberg MW; Dappen GM; Spayd RW; Wu TW; Jatlow P; Seligson D Clin Chem; 1984 Aug; 30(8):1310-3. PubMed ID: 6744577 [TBL] [Abstract][Full Text] [Related]
25. Chemical and clinical evaluation of the continuous-flow analyzer "SMAC". Schwartz MK; Bethune VG; Fleisher M; Pennacchia G; Menendez-Botet CJ; Lehman D Clin Chem; 1974 Aug; 20(8):1062-70. PubMed ID: 4850988 [No Abstract] [Full Text] [Related]
26. A comparison of 4-hydroxybenzoic acid hydrazide (PAHBAH) with other reagents for the determination of glucose. Lever M; Powell JC; Killip M; Small CW J Lab Clin Med; 1973 Oct; 82(4):649-55. PubMed ID: 4201981 [No Abstract] [Full Text] [Related]
27. Glucose assay systems: evaluation of a colorimetric hexokinase procedure. Wright WR; Rainwater JC; Tolle LD Clin Chem; 1971 Oct; 17(10):1010-5. PubMed ID: 4398480 [No Abstract] [Full Text] [Related]
28. Some methodological modifications of the technicon "SMA 12-60 AutoAnalyzer" system. Bigat TK; Saifer A Clin Chem; 1972 Jul; 18(7):630-42. PubMed ID: 4624877 [No Abstract] [Full Text] [Related]
29. [Investigations on the usefulness of the dry chemistry blood anaylsis system SPOTCHEM SP-4410in laboratory diagnosis of cattle]. Lorenz I; Aigner M; Klee W Berl Munch Tierarztl Wochenschr; 2001; 114(1-2):51-6. PubMed ID: 11225499 [TBL] [Abstract][Full Text] [Related]
30. The use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid. Chirillo R; Caenaro G; Pavan B; Pin A Clin Chem; 1979 Oct; 25(10):1744-8. PubMed ID: 476924 [TBL] [Abstract][Full Text] [Related]
31. Sensitisation and visualisation of biochemical measurements using the NAD/NADH system by means of Meldola blue. II. Application to the continuous flow determination of plasma glucose and urea. Orsonneau JL; Meflah K; Lustenberger P; Cornu G; Bernard S Clin Chim Acta; 1982 Oct; 125(2):185-92. PubMed ID: 7139960 [No Abstract] [Full Text] [Related]
32. The determination of calcium, glucose, urea and uric acid using the Kodak EKTACHEM multilayer film technology: an evaluation. Knoll E; Hafner F; Dettmer K; Wisser H J Clin Chem Clin Biochem; 1982 Jul; 20(7):491-8. PubMed ID: 7130907 [TBL] [Abstract][Full Text] [Related]
33. Postmortem chemistries on blood with particular reference to urea nitrogen, electrolytes, and bilirubin. Coe JI J Forensic Sci; 1974 Jan; 19(1):33-42. PubMed ID: 4853712 [No Abstract] [Full Text] [Related]
34. Performance characteristics of the Coulter Kem-O-Lab. Cherian AG; Huggard PK; Hill JG Clin Biochem; 1980 Feb; 13(1):55-9. PubMed ID: 7363452 [TBL] [Abstract][Full Text] [Related]
35. The normal ranges, with statistical analysis for seventeen blood constituents. Roberts LB Clin Chim Acta; 1967 Apr; 16(1):69-78. PubMed ID: 6036923 [No Abstract] [Full Text] [Related]
36. [Multiple simultaneous analyses. I. S.M.A. 12]. Jensen R; Labadie M Ann Biol Clin (Paris); 1968; 26(7):957-63. PubMed ID: 5727318 [No Abstract] [Full Text] [Related]
37. Evaluation of a glucose oxidase-peroxidase method adapted to the single-channel autoanalyzer and SMA 12-60. Miskiewicz SJ; Arnett BB; Simon GE Clin Chem; 1973 Feb; 19(2):253-7. PubMed ID: 4683985 [No Abstract] [Full Text] [Related]
38. Potential applications and pitfalls of dry reagent tests. An evaluation of the Ames Seralyzer. Clark PM; Broughton PM Ann Clin Biochem; 1983 Jul; 20 (Pt 4)():208-12. PubMed ID: 6614818 [TBL] [Abstract][Full Text] [Related]
39. [The Seralyzer system. Evaluation of the tests for glucose, urea-N, uric acid, bilirubin, cholesterol and lactate dehydrogenase]. Burger E; Lapin A; Gabl F Med Lab (Stuttg); 1982; 35(6):153-7. PubMed ID: 7162452 [No Abstract] [Full Text] [Related]
40. [The determination of capillary blood glucose using the automatic clinical analyzer (aca) Dupont (author's transl)]. Heinemann G J Clin Chem Clin Biochem; 1978 Apr; 16(4):235-8. PubMed ID: 641450 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]