These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 7356566)

  • 1. Mechanism of interference by hemoglobin in the determination of total bilirubin. I. Method of Malloy-Evelyn.
    Shull BC; Lees H; Li PK
    Clin Chem; 1980 Jan; 26(1):22-5. PubMed ID: 7356566
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanism of interference by hemoglobin in the determination of total bilirubin. II. Method of Jendrassik-Grof.
    Shull BC; Lees H; Li PK
    Clin Chem; 1980 Jan; 26(1):26-9. PubMed ID: 7356567
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diazo-based assay for total bilirubin in a coated thin film evaluated.
    Weiss JS; Sundberg MW; Dappen GM; Spayd RW; Wu TW; Jatlow P; Seligson D
    Clin Chem; 1984 Aug; 30(8):1310-3. PubMed ID: 6744577
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Direct spectrophotometry of bilirubin in serum of the newborn, with use of caffeine reagent.
    Vink KL; Schuurman W; van Gansewinkel R
    Clin Chem; 1988 Jan; 34(1):67-70. PubMed ID: 3338189
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A modified Malloy-Evelyn procedure for total bilirubin in microsamples.
    Shihabi ZK; Scaro J
    Am J Med Technol; 1977 Oct; 43(10):1004-7. PubMed ID: 920747
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.
    Brody JP; Valdes R; Savory J
    Clin Chem; 1979 Feb; 25(2):205-8. PubMed ID: 759015
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.
    Cherian AG; Soldin SJ; Hill JG
    Clin Chem; 1981 May; 27(5):748-52. PubMed ID: 7226499
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Candidate reference method for determination of total bilirubin in serum: development and validation.
    Doumas BT; Kwok-Cheung PP; Perry BW; Jendrzejczak B; McComb RB; Schaffer R; Hause LL
    Clin Chem; 1985 Nov; 31(11):1779-89. PubMed ID: 4053346
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Studies on the interference by haemoglobin in the determination of bilirubin.
    van der Woerd-de Lange JA; Guder WG; Schleicher E; Paetzke I; Schleithoff M; Wieland OH
    J Clin Chem Clin Biochem; 1983 Jul; 21(7):437-43. PubMed ID: 6619741
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A fast determination of serum bilirubin with the interference from hemolysis and turbidity by three wavelength spectrophotometry].
    Chai H; Dong YH
    Hua Xi Yi Ke Da Xue Xue Bao; 1989 Jun; 20(2):223-5. PubMed ID: 2591941
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin.
    Algeciras-Schimnich A; Cook WJ; Milz TC; Saenger AK; Karon BS
    Clin Biochem; 2007 Nov; 40(16-17):1311-6. PubMed ID: 17825810
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A modification of the acid diazo coupling method (Malloy-Evelyn) for the determination of serum total bilirubin.
    Parviainen MT
    Scand J Clin Lab Invest; 1997 May; 57(3):275-9. PubMed ID: 9238764
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A robust procedure for the automated measurement of total serum bilirubin using potassium ferricyanide.
    O'Leary N; Pembroke A; Duggan PF
    Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():175-9. PubMed ID: 8466149
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays.
    Ji JZ; Meng QH
    Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel reagent and method for direct determination of chloride in serum with a centrifugal analyzer.
    Law WT; Ertingshausen G
    Clin Chem; 1980 Dec; 26(13):1874-7. PubMed ID: 6254693
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of direct bilirubin by use of bilirubin oxidase.
    Doumas BT; Perry B; Jendrzejczak B; Davis L
    Clin Chem; 1987 Aug; 33(8):1349-53. PubMed ID: 3608152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Indican interference with six commercial procedures for measuring total bilirubin.
    Poon R; Hinberg IH
    Clin Chem; 1985 Jan; 31(1):92-4. PubMed ID: 3917384
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of direct spectrophotometric determinations of bilirubin with candidate reference method in sera of newborns.
    Hajzer S
    J Clin Chem Clin Biochem; 1989 Jul; 27(7):445-9. PubMed ID: 2794877
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interference with the enzymic measurement of cholesterol in serum by use of five reagent kits.
    Pesce MA; Bodourian SH
    Clin Chem; 1977; 23(4):757-60. PubMed ID: 844175
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectrophotometric evaluation of hemolysis in plasma by quantification of free oxyhemoglobin, methemoglobin, and methemalbumin in presence of bilirubin.
    Heckl C; Lang A; Rühm A; Sroka R; Duffield T; Vogeser M; Paal M
    J Biophotonics; 2021 May; 14(5):e202000461. PubMed ID: 33527705
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.