266 related articles for article (PubMed ID: 7359241)
1. The effects of thermal environment on heat balance and insensible water loss in low-birth-weight infants.
Bell EF; Gray JC; Weinstein MR; Oh W
J Pediatr; 1980 Mar; 96(3 Pt 1):452-9. PubMed ID: 7359241
[TBL] [Abstract][Full Text] [Related]
2. Infant incubators and radiant warmers.
Bell EF
Early Hum Dev; 1983 Oct; 8(3-4):351-75. PubMed ID: 6641579
[TBL] [Abstract][Full Text] [Related]
3. Effects of forced convection of heated air on insensible water loss and heat loss in preterm infants in incubators.
Okken A; Blijham C; Franz W; Bohn E
J Pediatr; 1982 Jul; 101(1):108-12. PubMed ID: 7086609
[TBL] [Abstract][Full Text] [Related]
4. Influence of variations in the ambient humidity on insensible water loss and thermoneutral environment of low birth weight infants.
Sauer PJ; Dane HJ; Visser HK
Acta Paediatr Scand; 1984 Sep; 73(5):615-9. PubMed ID: 6485780
[TBL] [Abstract][Full Text] [Related]
5. Heat balance in premature infants: comparative effects of convectively heated incubator and radiant warmer, with without plastic heat shield.
Bell EF; Weinstein MR; Oh W
J Pediatr; 1980 Mar; 96(3 Pt 1):460-5. PubMed ID: 7359242
[TBL] [Abstract][Full Text] [Related]
6. The heat balance of small babies nursed in incubators and under radiant warmers.
Wheldon AE; Rutter N
Early Hum Dev; 1982 Apr; 6(2):131-43. PubMed ID: 7094851
[TBL] [Abstract][Full Text] [Related]
7. A simple device for reducing insensible water loss in low-birth-weight infants.
Marks KH; Friedman Z; Maisels MJ
Pediatrics; 1977 Aug; 60(2):223-6. PubMed ID: 887337
[TBL] [Abstract][Full Text] [Related]
8. Oxygen consumption and insensible water loss in premature infants under radiant heaters.
Marks KH; Gunther RC; Rossi JA; Maisels MJ
Pediatrics; 1980 Aug; 66(2):228-32. PubMed ID: 6773022
[TBL] [Abstract][Full Text] [Related]
9. Transepidermal water loss in newborn infants. VI. Heat exchange with the environment in relation to gestational age.
Hammarlund K; Sedin G
Acta Paediatr Scand; 1982 Mar; 71(2):191-6. PubMed ID: 7136626
[TBL] [Abstract][Full Text] [Related]
10. Effect of heat shielding on convective and evaporative heat losses and on radiant heat transfer in the premature infant.
Baumgart S; Engle WD; Fox WW; Polin RA
J Pediatr; 1981 Dec; 99(6):948-56. PubMed ID: 7310591
[TBL] [Abstract][Full Text] [Related]
11. Oxygen consumption and insensible water loss in premature infants in single-versus double-walled incubators.
Yeh TF; Voora S; Lilien LD; Matwynshyn J; Srinivasan G; Pildes RS
J Pediatr; 1980 Dec; 97(6):967-71. PubMed ID: 6777480
[TBL] [Abstract][Full Text] [Related]
12. Water requirement of premature newborn infants.
Bell EF; Oh W
Acta Paediatr Scand Suppl; 1983; 305():21-6. PubMed ID: 6577774
[TBL] [Abstract][Full Text] [Related]
13. Oxygen consumption and temperature control of premature infants in a double-wall incubator.
Marks KH; Lee CA; Bolan CD; Maisels MJ
Pediatrics; 1981 Jul; 68(1):93-8. PubMed ID: 7243514
[TBL] [Abstract][Full Text] [Related]
14. A double-walled incubator alters the partition of body heat loss of premature infants.
Bell EF; Rios GR
Pediatr Res; 1983 Feb; 17(2):135-40. PubMed ID: 6402753
[TBL] [Abstract][Full Text] [Related]
15. Early skin-to-skin care in extremely preterm infants: thermal balance and care environment.
Karlsson V; Heinemann AB; Sjörs G; Nykvist KH; Agren J
J Pediatr; 2012 Sep; 161(3):422-6. PubMed ID: 22497906
[TBL] [Abstract][Full Text] [Related]
16. Radiant energy and insensible water loss in the premature newborn infant nursed under a radiant warmer.
Baumgart S
Clin Perinatol; 1982 Oct; 9(3):483-503. PubMed ID: 6761034
[TBL] [Abstract][Full Text] [Related]
17. Resting oxygen consumption of premature infants covered with a plastic thermal blanket.
Darnall RA; Ariagno RL
Pediatrics; 1979 Apr; 63(4):547-51. PubMed ID: 440864
[TBL] [Abstract][Full Text] [Related]
18. Reduction of oxygen consumption, insensible water loss, and radiant heat demand with use of a plastic blanket for low-birth-weight infants under radiant warmers.
Baumgart S
Pediatrics; 1984 Dec; 74(6):1022-8. PubMed ID: 6504622
[TBL] [Abstract][Full Text] [Related]
19. Thermal balance in term and preterm newborn infants nursed in an incubator equipped with a radiant heat source.
Sjörs G; Hammarlund K; Sedin G
Acta Paediatr; 1997 Apr; 86(4):403-9. PubMed ID: 9174228
[TBL] [Abstract][Full Text] [Related]
20. Transepidermal water loss in newborn infants. V. Evaporation from the skin and heat exchange during the first hours of life.
Hammarlund K; Nilsson GE; Oberg PA; Sedin G
Acta Paediatr Scand; 1980 May; 69(3):385-92. PubMed ID: 7376866
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]