These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 7359896)

  • 1. Measurement of the ohmic electrode-tissue contact resistance and the voltage applied to myocardium.
    Benzing G; Iltis R; Helmsworth JA; Schreiber T; Kaplan S
    J Biomed Eng; 1980 Jan; 2(1):3-8. PubMed ID: 7359896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Statistical analysis of the replacement circuit of the electrode- biological object-electrode system in electric stimulation of the heart].
    Grigorov SS; Egorova NM; Kuzenkov SV; Smo'lnikov LE
    Med Tekh; 1989; (1):7-10. PubMed ID: 2739558
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Acute voltage, charge, and energy thresholds as functions of electrode size for electrical stimulation of the canine heart.
    Lindemans FW; Zimmerman AN
    Cardiovasc Res; 1979 Jul; 13(7):383-91. PubMed ID: 487379
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electrode-heart interface: definition of the ideal electrode.
    Ripart A; Mugica J
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):410-21. PubMed ID: 6189086
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Injectable conductive hydrogel can reduce pacing threshold and enhance efficacy of cardiac pacemaker.
    An Z; Wu J; Li SH; Chen S; Lu FL; Xu ZY; Sung HW; Li RK
    Theranostics; 2021; 11(8):3948-3960. PubMed ID: 33664872
    [No Abstract]   [Full Text] [Related]  

  • 6. Temporary pacemaker treatment in open heart surgery: variation in myocardial threshold, tissue and interface impedances in man.
    Ohm OJ; Mörkrid L; Skagseth E
    Pacing Clin Electrophysiol; 1979 Mar; 2(2):162-74. PubMed ID: 95276
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intracardiac electrogram parameters, electrode surface area and pacer input impedance: their correlations.
    Antonioli EG; Baggioni FG; Grassi G
    G Ital Cardiol; 1980; 10(5):536-53. PubMed ID: 7450375
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fractally coated, 1.3 mm2 high impedance pacing electrode.
    Fröhlig G; Bolz A; Ströbel J; Rutz M; Lawall P; Schwerdt H; Schaldach M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Jun; 21(6):1239-46. PubMed ID: 9633066
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Telemetry guided pacemaker programming: impact of output amplitude and the use of low threshold leads on projected pacemaker longevity.
    Schwaab B; Fröhlig G; Schwerdt H; Heisel A; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 1):2055-63. PubMed ID: 9826856
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Techniques and significance of threshold measurement for cardiac pacing. Relationship to output circuit of cardiac pacemakers.
    Barold SS; Winner JA
    Chest; 1976 Dec; 70(6):760-6. PubMed ID: 1001053
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Demand failures occurring during permanent pacing in patients with serious heart disease.
    Ohm OJ
    Pacing Clin Electrophysiol; 1980 Jan; 3(1):44-55. PubMed ID: 6160493
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Paradigm shift in lead design.
    Irnich W
    Pacing Clin Electrophysiol; 1999 Sep; 22(9):1321-32. PubMed ID: 10527013
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sensor for right ventricular volumes using the trailing edge voltage of a pulse generator output.
    Chirife R
    Pacing Clin Electrophysiol; 1991 Nov; 14(11 Pt 2):1821-7. PubMed ID: 1721182
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ventricular cross stimulation in a dual chamber pacing system: phenomenon analysis.
    Puglisi A; Ricci R; Azzolini P; Peraldo Neja C; Fioranelli M; Speciale G; Angrisani G
    Pacing Clin Electrophysiol; 1990 Aug; 13(8):993-1001. PubMed ID: 1697965
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro estimation of the electrical performance of bipolar pacing electrode systems.
    Walton C; Economides AP
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1791-6. PubMed ID: 2463549
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Activated pyrolytic carbon tip pacing leads: an alternative to steroid-eluting pacing leads?
    Masini M; Lazzari M; Lorenzoni R; Domicelli AM; Micheletti A; Dianda R; Masini G
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1832-5. PubMed ID: 8945051
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physiological and electrical characteristics of the porous endocardial electrode.
    Amundson DC; MacCarter DJ; McArthur W; Mosharrafa M
    Med Instrum; 1979; 13(5):292-4. PubMed ID: 502928
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unipolar recording and pacing using a conductive introducer sheath as the indifferent electrode.
    Goldman DS; Buck JC; Larnard DJ
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):2014-7. PubMed ID: 8945088
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new efficient NanoTip lead.
    Stokes K; Bird T
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1901-5. PubMed ID: 1704564
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.