These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 7359940)

  • 21. Morphologic findings in explanted Hancock II porcine bioprostheses.
    Butany J; Yu W; Silver MD; David TE
    J Heart Valve Dis; 1999 Jan; 8(1):4-15. PubMed ID: 10096476
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Severe aortic insufficiency secondary to an aortic bioprosthesis tear.
    Beauchesne LM; Veinot JP; Higginson LA; Mesana T
    Cardiovasc Pathol; 2004; 13(3):165-7. PubMed ID: 15081473
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of high transvalvular velocities early after implantation of Freestyle stentless aortic bioprosthesis.
    Bach DS; Lemire MS; Eberhart D; Armstrong WF; Deeb GM
    J Heart Valve Dis; 2000 Jul; 9(4):536-43. PubMed ID: 10947047
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fatal hemolysis following replacement of the aortic and mitral valves. Report of a case.
    Taguchi K; Sasaki N; Matsuura Y; Tanimoto H
    Dis Chest; 1968 Jun; 53(6):788-94. PubMed ID: 5653760
    [No Abstract]   [Full Text] [Related]  

  • 25. [Successful mitral valve replacement in multiple organ failure due to mechanical hemolytic anemia after mitral valve repair: a case report].
    Nakayama Y; Naitoh K; Kosako Y; Ohteki H; Natsuaki M; Itoh T
    Kyobu Geka; 1994 Aug; 47(9):744-7. PubMed ID: 8057563
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Early clinical and hemodynamic evaluation of the aortic intact porcine bioprosthesis.
    Mullany CJ; Schaff HV; Orszulak TA; Miller FA
    J Heart Valve Dis; 1994 Nov; 3(6):641-7. PubMed ID: 8000607
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Mechanical hemolytic anemia after plastic surgery of the mitral valve].
    Tjorstad KO
    Tidsskr Nor Laegeforen; 1966 Aug; 86(16):1104-6. PubMed ID: 5919205
    [No Abstract]   [Full Text] [Related]  

  • 28. Severe intravascular hemolysis after triple valve replacement: cure by replacement of aortic and mitral valves with porcine xenografts.
    Camishion RC; Hughes JL
    Surgery; 1979 Mar; 85(3):246-8. PubMed ID: 570732
    [TBL] [Abstract][Full Text] [Related]  

  • 29. New Presentation of Hemolysis After Papillary Muscles Approximation for Mitral Valve Repair.
    Sarraj A; Calle Valda CM; Muñoz DE; Reyes G
    Ann Thorac Surg; 2017 Apr; 103(4):e321-e322. PubMed ID: 28359487
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Early postoperative outcome and hemodynamic performance of the sorin pericarbon stentless aortic valve.
    Bonacchi M; Giunti G; Prifti E; Rostagno C; Bini M; Frati G; Sani G
    J Heart Valve Dis; 2002 Sep; 11(5):703-9. PubMed ID: 12358408
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rapid calcification of the bovine pericardial valve in adolescence. Critical aortic stenosis, hemolytic anemia, and quantitative renal hemosiderosis.
    Radio SJ; Suvalsky SD; Hofschire PJ; Fleming WH; Rogler WC; McManus BM
    Arch Pathol Lab Med; 1985 Dec; 109(12):1118-21. PubMed ID: 3840987
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [The pathology of mitral porcine valves. Echocardiographic relief in 5 cases with intra-para-prosthetic regurgitation (author's transl)].
    Salati A; Narducci C; Pino PG; Chidichimo G; Jacovella G
    G Ital Cardiol; 1980; 10(5):605-9. PubMed ID: 7450381
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Blood traumatization after heart valve replacement (author's transl)].
    Neef H; Fischer U; Panzner R; Schober KL
    Zentralbl Chir; 1977; 102(1):14-23. PubMed ID: 842164
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Studies on blood traumatization following heart-valve prosthesis].
    Neef H; Fischer U; Panzner R
    Z Gesamte Inn Med; 1977 Mar; 32(6):138-43. PubMed ID: 868192
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis.
    Vrandecic M; Fantini FA; Filho BG; de O; da C; Vrandecic E
    J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Clinical picture of hemolytic syndrome after implantation of artificial cardiac valves].
    Nelius D; Heublein B; Parsi RA
    Dtsch Gesundheitsw; 1970 Nov; 25(45):2132-6. PubMed ID: 5487974
    [No Abstract]   [Full Text] [Related]  

  • 37. [A case of failure of mitroflow pericardial valve with severe hemolytic anemia].
    Ohkado A; Akiyama K; Hirota J; Shiina Y
    Kyobu Geka; 1995 Nov; 48(12):1013-5. PubMed ID: 8538101
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A rapid structural degeneration of a porcine mitral valve.
    Miura T; Hazama S; Iwasaki K; Izumi K; Matsukuma S; Eishi K
    Ann Thorac Surg; 2012 May; 93(5):e113-4. PubMed ID: 22541231
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Early failures of Ionescu-Shiley bioprosthesis after mitral valve replacement in children.
    Galioto Fm; Midgley FM; Kapur S; Perry LW; Watson DC; Shapiro SR; Ruckman RN; Scott LP
    J Thorac Cardiovasc Surg; 1982 Feb; 83(2):306-10. PubMed ID: 7057671
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography.
    Ionescu A; Fraser AG; Butchart EG
    Heart; 2003 Nov; 89(11):1316-21. PubMed ID: 14594888
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.