BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 7360800)

  • 1. Modification of temporary below-knee sockets for amputees with absent or diminished sensation.
    McPoil TG; Bergtholdt HT; Hunt GC
    Phys Ther; 1980 Apr; 60(4):437-8. PubMed ID: 7360800
    [No Abstract]   [Full Text] [Related]  

  • 2. Temporary prosthetic fitting for below-knee amputation.
    Ozyalcin H; Sesli E
    Prosthet Orthot Int; 1989 Aug; 13(2):86-9. PubMed ID: 2780266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Socket design and manufacturing technique for through-knee stumps.
    Botta P; Baumgartner R
    Prosthet Orthot Int; 1983 Aug; 7(2):100-3. PubMed ID: 6622226
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A pneumatic weight-bearing temporary prosthesis for below-knee amputees.
    Little JM
    Lancet; 1971 Feb; 1(7693):271-3. PubMed ID: 4100020
    [No Abstract]   [Full Text] [Related]  

  • 5. Fabrication of a polysar, temporary prosthesis in a hospital setting.
    Tucker J; Sullivan RA
    Arch Phys Med Rehabil; 1975 Mar; 56(3):125-30. PubMed ID: 1119920
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CAD/CAM evaluation of the fit of trans-tibial sockets for trans-tibial amputation stumps.
    Isozaki K; Hosoda M; Masuda T; Morita S
    J Med Dent Sci; 2006 Mar; 53(1):51-6. PubMed ID: 16722145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiological evaluation of prosthetic fit in below-the-knee amputees.
    Newton RL; Morgan D; Schreiber MH
    Skeletal Radiol; 1988; 17(4):276-80. PubMed ID: 3212490
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prefabricated below-knee sockets for the maturing stump.
    Breakey JW
    Bull Prosthet Res; 1973; 10(19):42-51. PubMed ID: 4767329
    [No Abstract]   [Full Text] [Related]  

  • 9. Tolerance of early walking with total contact among below-knee amputees--a randomized test.
    Liedberg E; Hommerberg H; Persson BM
    Prosthet Orthot Int; 1983 Aug; 7(2):91-5. PubMed ID: 6622240
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plastic soda bottles: a reusable material for making transradial sockets.
    Wu Y; Casanova HR; Ikeda AJ
    Prosthet Orthot Int; 2009 Jun; 33(2):100-6. PubMed ID: 19367513
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modifications of the temporary below-knee prothesis.
    Giaccone V; Cohen M
    Phys Ther; 1975 May; 55(5):508-10. PubMed ID: 1129367
    [No Abstract]   [Full Text] [Related]  

  • 12. Socket design for the above-knee amputee.
    Foort J
    Prosthet Orthot Int; 1979 Aug; 3(2):73-81. PubMed ID: 503796
    [No Abstract]   [Full Text] [Related]  

  • 13. The TC double socket above-knee prosthesis.
    Koike K; Ishikura Y; Kakurai S; Imamura T
    Prosthet Orthot Int; 1981 Dec; 5(3):129-34. PubMed ID: 7329773
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Immediate rigid dressing for amputees. Advantages and misconceptions.
    Cummings V
    N Y State J Med; 1974 Jun; 74(6):980-3. PubMed ID: 4525689
    [No Abstract]   [Full Text] [Related]  

  • 15. [Crural amputation stump by Pirogov's method and prosthesis in the invalids].
    Kondrashin NI; Sanin VG; Iusupov VK
    Ortop Travmatol Protez; 1975 Dec; (12):1-6. PubMed ID: 1226275
    [No Abstract]   [Full Text] [Related]  

  • 16. [Dermatosis on above-knee and below-knee amputation stumps].
    Noacco G; Mercier A; Le Coz CJ; Lacour JP
    Ann Dermatol Venereol; 2000 Mar; 127(3):317-23. PubMed ID: 10804313
    [No Abstract]   [Full Text] [Related]  

  • 17. A simplified model for the short-below-knee stump.
    Nissan M
    J Biomech; 1977; 10(10):651-8. PubMed ID: 591520
    [No Abstract]   [Full Text] [Related]  

  • 18. Use of temporary plaster of plastic pylons preparatory to fitting a permanent above-knee or below-knee prosthesis.
    Goldner JL; Clippinger FW; Titus BR
    Bull Prosthet Res; 1970; 10(13):87-107. PubMed ID: 5521918
    [No Abstract]   [Full Text] [Related]  

  • 19. Evaluation of synthetic balata for fabricating sockets for below-knee amputation stumps.
    Wilson AB
    Artif Limbs; 1970; 14(2):58-67. PubMed ID: 5479726
    [No Abstract]   [Full Text] [Related]  

  • 20. Computer aided design of prosthetic sockets for below-knee amputees.
    Saunders CG; Foort J; Bannon M; Lean D; Panych L
    Prosthet Orthot Int; 1985 Apr; 9(1):17-22. PubMed ID: 4000906
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.