These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Calorimetric and ionimetric dosimetry intercomparisons I: U.S. neutron radiotherapy centers. McDonald JC; Ma IC; Liang J; Eenmaa J; Awschalom M; Smathers JB; Graves R; August LS; Shapiro P Med Phys; 1981; 8(1):39-43. PubMed ID: 7207426 [TBL] [Abstract][Full Text] [Related]
3. A comparison of calculated and measured W values in tissue-equivalent gas mixtures. Krajcar-Bronić I; Srdoc D Radiat Res; 1994 Jan; 137(1):18-24. PubMed ID: 8265783 [TBL] [Abstract][Full Text] [Related]
4. Response of tissue-equivalent ionization chamber to 15-MeV neutrons. Barschall HH; Goldberg E Med Phys; 1977; 4(2):141-4. PubMed ID: 850510 [TBL] [Abstract][Full Text] [Related]
5. Determination of the kerma factors in tissue-equivalent plastic, C, Mg, and Fe for 14.7-MeV neutrons. Wuu CS; Milavickas LR Med Phys; 1987; 14(6):1007-14. PubMed ID: 3696064 [TBL] [Abstract][Full Text] [Related]
6. [On the optimum energy of incident neutrons in neutron capture therapy]. Riabukhin IaS Med Radiol (Mosk); 1966 Jun; 11(6):9-12. PubMed ID: 5988791 [No Abstract] [Full Text] [Related]
7. New calculations of neutron kerma coefficients and dose equivalent. Liu Z; Chen J J Radiol Prot; 2008 Jun; 28(2):185-93. PubMed ID: 18495982 [TBL] [Abstract][Full Text] [Related]
8. Ionisation measurements and the derivation of Wn in acetylene and carbon dioxide irradiated with neutrons. Delafield HJ; Harrison KG Phys Med Biol; 1979 Mar; 24(2):271-85. PubMed ID: 450969 [TBL] [Abstract][Full Text] [Related]
9. Dose inhomogeneities for photons and neutrons near interfaces. Broerse JJ; Zoetelief J Radiat Prot Dosimetry; 2004; 112(4):509-17. PubMed ID: 15623886 [TBL] [Abstract][Full Text] [Related]
10. A tissue equivalent proportional counter filled with a mixture of tissue equivalent gas and 3He for neutron monitoring. Chau Q; Ménard S Radiat Prot Dosimetry; 2006; 122(1-4):390-2. PubMed ID: 17314087 [TBL] [Abstract][Full Text] [Related]
11. Neutron kerma factors and water equivalence of some tissue substitutes. Singh VP; Badiger NM; Vega-Carrillo HR Appl Radiat Isot; 2015 Sep; 103():115-9. PubMed ID: 26073270 [TBL] [Abstract][Full Text] [Related]
12. Differential absorbed dose distributions in lineal energy for neutrons and gamma rays at the mono-energetic neutron calibration facility. Takada M; Baba M; Yamaguchi H; Fujitaka K Radiat Prot Dosimetry; 2005; 114(4):481-90. PubMed ID: 15914511 [TBL] [Abstract][Full Text] [Related]
13. Recombination chambers filled with different gases--studies of possible application for BNCT beam dosimetry. Tulik P; Golnik N; Zielczynski M Radiat Prot Dosimetry; 2004; 110(1-4):669-73. PubMed ID: 15353728 [TBL] [Abstract][Full Text] [Related]
14. Ion chamber gas-to-wall conversion factors for fast neutron dosimetry. Miranda JG; DeLuca PM; Chadwick MB Radiat Prot Dosimetry; 2004; 110(1-4):15-25. PubMed ID: 15353616 [TBL] [Abstract][Full Text] [Related]
15. Optimum beam energy and geometry for neutron capture therapy. ANL-7635. Frigerio NA ANL Rep; 1969 Dec; ():135-7. PubMed ID: 5310754 [No Abstract] [Full Text] [Related]
16. Precision measurements of the np scattering differential cross section in the intermediate energy region. Mermod P; Blomgren J; Nilsson L; Pomp S; Ohrn A; Osterlund M; Prokofiev A; Tippawan U Radiat Prot Dosimetry; 2007; 126(1-4):109-12. PubMed ID: 17595211 [TBL] [Abstract][Full Text] [Related]
19. Tissue current-to-dose conversion factors for neutrons with energies from 0.5 to 60 MeV. ORNL-4032. Irving DC; Alsmiller RG; Moran HS ORNL; 1967 Jul; ():1-85. PubMed ID: 4970502 [No Abstract] [Full Text] [Related]
20. A method for measuring tissue-equivalent dose using a pin diode and activation foil in epithermal neutron beams with EN < 100 keV. Carolan MG; Rosenfeld AB Radiat Prot Dosimetry; 2006; 120(1-4):337-40. PubMed ID: 16644975 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]