BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 7369183)

  • 1. Two new artifacts in automated coagulation testing.
    Gutman SI; Didisheim P; Markowitz H
    Am J Clin Pathol; 1980 Apr; 73(4):583-8. PubMed ID: 7369183
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An evaluation of four automated coagulation instruments.
    Klee GG; Didisheim P; Johnson RJ; Giere GM
    Am J Clin Pathol; 1978 Oct; 70(4):646-54. PubMed ID: 707433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Evaluation of the performance of the Coagulyzer II (Lancer)].
    Massignon D; Saumet M; Giraud M; Coeur P
    Nouv Rev Fr Hematol (1978); 1984; 26(5):339-42. PubMed ID: 6504697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prothrombin times and clottable fibrinogen determination on an automated coagulation laboratory (ACL-810).
    Castillo JB; Farag AM; Mammen EF; Sachs RJ
    Thromb Res; 1989 Jul; 55(2):213-9. PubMed ID: 2781525
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of a centrifugal analyzer for a chromogenic prothrombin time, a chromogenic activated partial thromboplastin time and a kinetic fibrinogen assay in a routine hospital laboratory.
    de Metz M; van Wersch JW
    Haemostasis; 1987; 17(5):254-9. PubMed ID: 3666583
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is duplicate testing for prothrombin time and activated partial thromboplastin time necessary?
    Keshgegian AA; Mann JM; Cooper JH
    Arch Pathol Lab Med; 1986 Jun; 110(6):520-2. PubMed ID: 3754725
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Prothrombin time, activated partial thromboplastin time, plasma fibrinogen determination. Comparison of two automated coagulation systems: Koagulab 40-A and ACL-100].
    Barbe D; Bauduer F; Tanguy A
    Ann Biol Clin (Paris); 1991; 49(10):507-13. PubMed ID: 1807170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of the Coag-a-Pet Dual Channel in the routine haemostatic laboratory.
    Rowan RM; Fraser C; Hill HM
    Clin Lab Haematol; 1979; 1(2):129-37. PubMed ID: 535309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of automatic and semiautomatic coagulation assay instruments.
    Drewinko B; Roe E; Hasler D; Wallace B; Johnston D
    Clin Lab Haematol; 1980; 2(3):215-26. PubMed ID: 7428312
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation and performance characteristics of the automated coagulation analyzer ACL TOP.
    Appert-Flory A; Fischer F; Jambou D; Toulon P
    Thromb Res; 2007; 120(5):733-43. PubMed ID: 17275069
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the Q analyzer, a new cap-piercing fully automated coagulometer with clotting, chromogenic, and immunoturbidometric capability.
    Kitchen S; Woolley A
    Blood Coagul Fibrinolysis; 2013 Jan; 24(1):28-34. PubMed ID: 23249565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of five manually operated coagulation instruments.
    Beckala HR; Leavelle DE; Didisheim P
    Am J Clin Pathol; 1978 Jul; 70(1):71-5. PubMed ID: 696674
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A simultaneous evaluation of three multiparametric coagulation instruments: BFA, HEMOLAB and STA.
    Pernod G; Bouabana B; Desrousseau B; Mossuz P; Drevait JM; Maljournal B; Rouhan D; Kolodié L; Polack B
    Nouv Rev Fr Hematol (1978); 1994 Dec; 36(6):409-18. PubMed ID: 7753611
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated clot-based methods in coagulation testing: current and future considerations.
    Walenga JM; Hoppensteadt D; Fareed J; Silberman S; Shelvin P
    Semin Thromb Hemost; 1983 Oct; 9(4):245-9. PubMed ID: 6658458
    [No Abstract]   [Full Text] [Related]  

  • 15. Effects of reagent and instrument on prothrombin times, activated partial thromboplastin times and patient/control ratios.
    Naghibi F; Han Y; Dodds WJ; Lawrence CE
    Thromb Haemost; 1988 Jun; 59(3):455-63. PubMed ID: 3187932
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of a bench-top coagulation analyzer for measurement of prothrombin time, activated partial thromboplastin time, and fibrinogen concentrations in healthy dogs.
    Mineo HK; Garabed RB
    Am J Vet Res; 2007 Dec; 68(12):1342-7. PubMed ID: 18052739
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance characteristics of the turbidimetric ACL-TOP CTS 300 coagulation analyzer in dogs and cats.
    Sharkey LC; Little KJ; Williams KD; Todd JM; Richardson R; Gwynn AD; Rendahl A
    J Vet Emerg Crit Care (San Antonio); 2018 Jul; 28(4):317-325. PubMed ID: 29901847
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Rapid centrifugation for routine coagulation testing].
    Boudaoud L; Divaret G; Marie P; Bezeaud A
    Ann Biol Clin (Paris); 2006; 64(4):315-7. PubMed ID: 16829473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurements of some blood clotting factors using a centrifugal analyser (Multistat III).
    Christensen NJ
    Scand J Clin Lab Invest; 1983 Oct; 43(6):521-6. PubMed ID: 6658368
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical implications of clotting screens.
    Thorell SE; Nash MJ; Thachil J
    Int J Lab Hematol; 2015 Feb; 37(1):8-13. PubMed ID: 24636194
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.