These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 7370154)

  • 1. Enfluratec vaporizer.
    Davies JR
    Br J Anaesth; 1980 Mar; 52(3):356-7. PubMed ID: 7370154
    [No Abstract]   [Full Text] [Related]  

  • 2. [Evaluation of an enflurance vaporizer: the Enfluratec].
    Nivoche Y; Henzel D; Desmonts JM
    Anesth Analg (Paris); 1978; 35(1):183-90. PubMed ID: 677496
    [No Abstract]   [Full Text] [Related]  

  • 3. Chemistry of halothane-enflurane mixtures applied to anesthesia.
    Korman B; Ritchie IM
    Anesthesiology; 1985 Aug; 63(2):152-6. PubMed ID: 4025864
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of the accuracy of the Siemens injection vaporizer and the Enfluratec 3 vaporizer.
    Cozanitis DA; Rosenberg PH; Merrett JD
    Anaesthesiol Reanim; 1994; 19(3):75-7. PubMed ID: 8086093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Closed-circuit halothane and enflurane using an in-circle Goldman vaporizer.
    Jordan MJ; Bushman JA
    Br J Anaesth; 1981 Dec; 53(12):1285-90. PubMed ID: 7032559
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A versatile vaporizer convenient for low flow and closed system anesthesia].
    Toyooka H; Morita S; Yamada Y; Higuchi M; Akune T; Inada Y
    Masui; 1984 Mar; 33(3):296-301. PubMed ID: 6737683
    [No Abstract]   [Full Text] [Related]  

  • 7. Free-standing vaporizers. Another hazard.
    Kelly DA
    Anaesthesia; 1985 Jul; 40(7):661-3. PubMed ID: 4025770
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inadvertent change of volatile anesthetics in anesthesia machines.
    Karis JH; Menzel DB
    Anesth Analg; 1982 Jan; 61(1):53-5. PubMed ID: 7198415
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Failure of the agent-specific filling device.
    Riegle EV; Desertspring D
    Anesthesiology; 1990 Aug; 73(2):353-4. PubMed ID: 2382861
    [No Abstract]   [Full Text] [Related]  

  • 10. [A research on misfilling of inhalation anesthetics into vaporizers].
    Kumazawa T; Kashimoto S; Tanaka Y; Manabe M; Takashima S; Kinoshita H; Yamamoto I
    Masui; 1984 Aug; 33(8):882-8. PubMed ID: 6512960
    [No Abstract]   [Full Text] [Related]  

  • 11. Respiratory and cardiovascular effects of halothane, isoflurane and enflurane delivered via a Jackson-Rees breathing system in temperature controlled and uncontrolled rats.
    Dardai E; Heavner JE
    Methods Find Exp Clin Pharmacol; 1987 Nov; 9(11):717-20. PubMed ID: 3448450
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Vaporizer malfunction--a cause of high concentration halothane vapor delivery].
    Yamada T; Masuda J; Takeda J; Sekiguchi H; Fukushima K
    Masui; 1994 Mar; 43(3):421-5. PubMed ID: 8182893
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [NORMAC--a simple instrument to measure the inspiratory and end- expiratory concentrations of halothane, enflurane, and isoflurane. Clinical use and laboratory investigations].
    Baer B
    Anaesthesist; 1987 May; 36(5):242-5. PubMed ID: 3631492
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High halothane concentrations from reversed flow in a vaporizer.
    Railton R; Inglis MD
    Anaesthesia; 1986 Jun; 41(6):672-3. PubMed ID: 3728950
    [No Abstract]   [Full Text] [Related]  

  • 15. [Automated system for the inhalation administration of anesthetics in a closed circuit].
    Texier JJ; Feiss P; Mercury P; Bricq M; Durand JL
    Agressologie; 1990; 31(7):445-9. PubMed ID: 2088108
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Agent-specific filling devices. An evaluation of two prototypes.
    O'Carroll TM; Greenbaum R; Thornton PG
    Anaesthesia; 1980 Aug; 35(8):807-10. PubMed ID: 7446920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Evaluation of anesthetic vaporizers: application of the Normac infrared anesthetic agent monitor AA 102].
    Nishioka K; Hoshi K; Takahashi S
    Masui; 1987 May; 36(5):778-83. PubMed ID: 3656647
    [No Abstract]   [Full Text] [Related]  

  • 18. [Blood gas analysis using a simple halothane vaporizer].
    Ahnefeld FW; Halmágyi M; Nolte H
    Acta Anaesthesiol Scand Suppl; 1966; 23():523-8. PubMed ID: 6003661
    [No Abstract]   [Full Text] [Related]  

  • 19. A test of two types of halothane vaporizer.
    Ha JM; Hellewell J; Fischr EL; Burns TH; Fuzey GJ
    Br J Anaesth; 1966 Jun; 38(6):494-7. PubMed ID: 5944027
    [No Abstract]   [Full Text] [Related]  

  • 20. [On the efficacy of the Oxford Miniature Vaporizer (OMV)for halothane (author's transl)].
    Haldemann G; Hossli G; Schaer H
    Anaesthesist; 1973 Aug; 22(8):339-44. PubMed ID: 4749218
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.