BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

208 related articles for article (PubMed ID: 7378954)

  • 1. Principles of less rigid internal fixation with plates.
    Akeson WH; Coutts RD; Woo SL
    Can J Surg; 1980 May; 23(3):235-9. PubMed ID: 7378954
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Less rigid internal fixation plates: historical perspectives and new concepts.
    Woo SL; Lothringer KS; Akeson WH; Coutts RD; Woo YK; Simon BR; Gomez MA
    J Orthop Res; 1984; 1(4):431-49. PubMed ID: 6491792
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new approach to the design of internal fixation plates.
    Woo SL; Simon BR; Akeson WH; Gomez MA; Seguchi Y
    J Biomed Mater Res; 1983 May; 17(3):427-39. PubMed ID: 6863347
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stress analyses after femoral shaft osteotomy fixed by various plates with different rigidities in simulation test.
    Xu XX; Zhang X; Liu JG; Wang JB; Shi DG; Liu SX
    Chin Med J (Engl); 1993 Feb; 106(2):127-31. PubMed ID: 8504696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of delayed internal fixation on healing of the osteotomized dog radius.
    Coutts RD; Woo SL; Boyer J; Doty D; Gonsalves M; Amiel D; Akeson WH
    Clin Orthop Relat Res; 1982 Mar; (163):254-60. PubMed ID: 7067260
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rigid or sliding plate. A mechanical evaluation of osteotomy fixation in sheep.
    Panagiotopoulos E; Fortis AP; Lambiris E; Kostopoulos V
    Clin Orthop Relat Res; 1999 Jan; (358):244-9. PubMed ID: 9973997
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of stainless steel and composite plates in the healing of diaphyseal osteotomies of the dog radius: report on a short term study.
    Coutts RE; Akeson WH; Woo S; Matthews JV; Gonsalves M; Amiel D
    Orthop Clin North Am; 1976 Jan; 7(1):223-9. PubMed ID: 1256790
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Experimental studies on "less rigid" polyacetal plates for fracture fixation (author's transl)].
    Kusunose K
    Nihon Seikeigeka Gakkai Zasshi; 1982 May; 56(5):399-414. PubMed ID: 7108319
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical evaluation of the modified double-plating fixation for the distal radius fracture.
    Cheng HY; Lin CL; Lin YH; Chen AC
    Clin Biomech (Bristol, Avon); 2007 Jun; 22(5):510-7. PubMed ID: 17328995
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Structural and biomechanical changes in bone after rigid plate fixation.
    Slätis P; Paavolainen P; Karaharju E; Holmström T
    Can J Surg; 1980 May; 23(3):247-50. PubMed ID: 7378956
    [No Abstract]   [Full Text] [Related]  

  • 11. The mechanical and morphological properties of bone beneath internal fixation plates of differing rigidity.
    Claes L
    J Orthop Res; 1989; 7(2):170-7. PubMed ID: 2918416
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Healing of canine femoral osteotomies. Effects of compression plates versus Eggers' plates.
    Daum WJ; Chang SL; Simmons DJ; Webster D; Shoenecker PL
    Clin Orthop Relat Res; 1983 Nov; (180):291-300. PubMed ID: 6627793
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fixation compliance in a mouse osteotomy model induces two different processes of bone healing but does not lead to delayed union.
    Gröngröft I; Heil P; Matthys R; Lezuo P; Tami A; Perren S; Montavon P; Ito K
    J Biomech; 2009 Sep; 42(13):2089-96. PubMed ID: 19643416
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study.
    Peine R; Rikli DA; Hoffmann R; Duda G; Regazzoni P
    J Hand Surg Am; 2000 Jan; 25(1):29-33. PubMed ID: 10642470
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Healing of fractures with freeze-dried cortical bone plates. Comparison with compression plating.
    Malinin T; Latta LL; Wagner JL; Brown MD
    Clin Orthop Relat Res; 1984 Nov; (190):281-6. PubMed ID: 6386259
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study.
    Koh S; Morris RP; Patterson RM; Kearney JP; Buford WL; Viegas SF
    J Hand Surg Am; 2006; 31(5):771-9. PubMed ID: 16713841
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.
    Trease C; McIff T; Toby EB
    J Hand Surg Am; 2005 Jul; 30(4):756-63. PubMed ID: 16039369
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Synthesis Pengo System plates for the treatment of long-bone diaphyseal fractures in dogs.
    Rahal C; Otoni CC; Pereira Júnior OC; Blum AL; Vulcano LC
    Vet Comp Orthop Traumatol; 2008; 21(1):59-63. PubMed ID: 18288345
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The design and analysis of a laminated partially degradable composite bone plate for fracture fixation.
    Zimmerman M; Parsons JR; Alexander H
    J Biomed Mater Res; 1987 Dec; 21(A3 Suppl):345-61. PubMed ID: 3429470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Development of static three dimensional screw-plate system and the biomechanic features thereof, a comparative study].
    Liang JY; Li KH; Liao QD; Zhu Y; Hu YH; Lei GH
    Zhonghua Yi Xue Za Zhi; 2009 Jan; 89(1):12-6. PubMed ID: 19489236
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.