BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 738086)

  • 1. A simplified method to determine functional residual capacity during mechanical ventilation.
    Heldt GP; Peters RM
    Chest; 1978 Nov; 74(5):492-6. PubMed ID: 738086
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A practical procedure for measuring functional residual capacity during mechanical ventilation with or without PEEP.
    Weaver LJ; Pierson DJ; Kellie R; Bonner B; Craig KC
    Crit Care Med; 1981 Dec; 9(12):873-7. PubMed ID: 7032846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.
    Brewer L; Orr J; Fulcher E; Markewitz B
    J Clin Monit Comput; 2011 Dec; 25(6):397-404. PubMed ID: 22057246
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation.
    Ibañez J; Raurich JM; Moris SG
    Crit Care Med; 1982 May; 10(5):332-4. PubMed ID: 7042202
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume.
    Valta P; Takala J; Foster R; Weissman C; Kinney JM
    Chest; 1992 Jul; 102(1):234-8. PubMed ID: 1623760
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.
    Ibañez J; Raurich JM; Moris SG
    Intensive Care Med; 1983; 9(2):91-3. PubMed ID: 6343447
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A radiographic method for measuring steady-state functional residual capacity in the supine patient. A method suitable for sleep studies.
    Block AJ; Bush CM; White C; Boysen PG; Wynne JW; Taasan VC
    Am Rev Respir Dis; 1981 Sep; 124(3):330-2. PubMed ID: 7283267
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Changes in functional residual capacity of the lung after operation.
    Meyers JR; Lembeck L; O'Kane H; Baue AE
    Arch Surg; 1975 May; 110(5):576-83. PubMed ID: 1093513
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relationship between functional residual capacity, respiratory compliance, and oxygenation in patients ventilated after cardiac surgery.
    Heinze H; Sedemund-Adib B; Heringlake M; Meier T; Eichler W
    Respir Care; 2010 May; 55(5):589-94. PubMed ID: 20420730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of functional residual capacity during mechanical ventilation for acute respiratory failure. A comparison between closed and an open-circuit helium dilution technique.
    Hylkema BS; Barkmeijer-Degenhart P; van der Mark TW; Peset R; Sluiter HJ
    Chest; 1982 Jan; 81(1):27-30. PubMed ID: 7053937
    [No Abstract]   [Full Text] [Related]  

  • 11. [A simple method for determination of the functional residual capacity during artificial ventilation (author's transl)].
    Stokke T; Hensel I; Burchardi H
    Anaesthesist; 1981 Mar; 30(3):124-30. PubMed ID: 7224140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Oscillatory determination of functional residual capacity (FRC)].
    Korn V; Franetzki M; Smidt U
    Acta Med Austriaca; 1979; 6(4):136-7. PubMed ID: 552776
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of an acoustic helium analyzer and microprocessor for rapid measurement of absolute lung volume during mechanical ventilation.
    Gillespie DJ
    Crit Care Med; 1985 Feb; 13(2):118-21. PubMed ID: 3967501
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurements of functional residual capacity during intensive care treatment: the technical aspects and its possible clinical applications.
    Heinze H; Eichler W
    Acta Anaesthesiol Scand; 2009 Oct; 53(9):1121-30. PubMed ID: 19681779
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurement of functional residual capacity and pulmonary carbon monoxide diffusing capacity during mechanical ventilation with PEEP.
    Kondo T; Kurata T; Takasaki Y; Ohta Y; Yamabayashi H
    Tokai J Exp Clin Med; 1982 Sep; 7(5):561-73. PubMed ID: 6763783
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automated sulfur hexafluoride washout functional residual capacity measurement system for any mode of mechanical ventilation as well as spontaneous respiration.
    East TD; Wortelboer PJ; van Ark E; Bloem FH; Peng L; Pace NL; Crapo RO; Drews D; Clemmer TP
    Crit Care Med; 1990 Jan; 18(1):84-91. PubMed ID: 2293972
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An analysis of a rebreathing method for measuring lung volume in the premature infant.
    Ronchetti R; Stocks J; Keith I; Godfrey S
    Pediatr Res; 1975 Oct; 9(10):797-802. PubMed ID: 1187243
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of functional residual capacity by sulfur hexafluoride in small-volume lungs during spontaneous breathing and mechanical ventilation.
    Schulze A; Schaller P; Töpfer A; Kirpalani H
    Pediatr Res; 1994 Apr; 35(4 Pt 1):494-9. PubMed ID: 8047388
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Oxygen wash-in method for monitoring functional residual capacity.
    Mitchell RR; Wilson RM; Holzapfel L; Benis AM; Sierra D; Osborn JJ
    Crit Care Med; 1982 Aug; 10(8):529-33. PubMed ID: 7094601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of functional residual capacity by modified multiple breath nitrogen washout for spontaneously breathing and mechanically ventilated patients.
    Brewer LM; Orr JA; Sherman MR; Fulcher EH; Markewitz BA
    Br J Anaesth; 2011 Nov; 107(5):796-805. PubMed ID: 21752798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.