These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 739015)

  • 1. Evaluation of couple/crevice corrosion by prosthetic alloys under in vivo conditions.
    Rostoker W; Galante JO; Lereim P
    J Biomed Mater Res; 1978 Nov; 12(6):823-9. PubMed ID: 739015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a precipitation hardened wrought cobalt-nickel-chromium-titanium alloy for surgical implants.
    Cahoon JR; Hill LD
    J Biomed Mater Res; 1978 Nov; 12(6):805-21. PubMed ID: 739014
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of proteins on metallic corrosion.
    Clark GC; Williams DF
    J Biomed Mater Res; 1982 Mar; 16(2):125-34. PubMed ID: 7061531
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study on hemocompatibility and corrosion behavior of ion implanted TiNi shape memory alloy and Co-based alloys.
    Liang C; Huang N
    J Biomed Mater Res A; 2007 Oct; 83(1):235-40. PubMed ID: 17607737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Corrosion of dental titanium alloys binary system of Ti-Al, Ti-Cu, Ti-Ni].
    Oda Y; Funasaka M; Sumii T
    Shika Zairyo Kikai; 1990 Mar; 9(2):314-9. PubMed ID: 2135523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy.
    Kawalec JS; Brown SA; Payer JH; Merritt K
    J Biomed Mater Res; 1995 Jul; 29(7):867-73. PubMed ID: 7593026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cast vs. wrought cobalt-chromium surgical implant alloys.
    Devine TM; Wulff J
    J Biomed Mater Res; 1975 Mar; 9(2):151-67. PubMed ID: 1176476
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Release and detection of dental corrosion products in vivo: development of an experimental model in rabbits.
    Reuling N; Wisser W; Jung A; Denschlag HO
    J Biomed Mater Res; 1990 Aug; 24(8):979-91. PubMed ID: 2394767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion behavior of nickel-containing alloys in artificial sweat.
    Randin JP
    J Biomed Mater Res; 1988 Jul; 22(7):649-66. PubMed ID: 3403567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion behavior of cast and forged cobalt-based alloys for double-alloy joint endoprostheses.
    Süry P; Semlitsch M
    J Biomed Mater Res; 1978 Sep; 12(5):723-41. PubMed ID: 701305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrochemical corrosion of titanium and titanium-based alloys.
    Kuphasuk C; Oshida Y; Andres CJ; Hovijitra ST; Barco MT; Brown DT
    J Prosthet Dent; 2001 Feb; 85(2):195-202. PubMed ID: 11208211
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Couple corrosion among alloys for skeletal prostheses.
    Rostoker W; Pretzel CW; Galante JO
    J Biomed Mater Res; 1974 Nov; 8(6):407-19. PubMed ID: 4436342
    [No Abstract]   [Full Text] [Related]  

  • 14. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
    Gilbert JL; Buckley CA; Jacobs JJ
    J Biomed Mater Res; 1993 Dec; 27(12):1533-44. PubMed ID: 8113241
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical failure of hydroxyapatite-coated titanium and cobalt-chromium-molybdenum alloy implants. An animal study.
    Nimb L; Gotfredsen K; Steen Jensen J
    Acta Orthop Belg; 1993; 59(4):333-8. PubMed ID: 8116363
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo transport and excretion of corrosion products from accelerated anodic corrosion of porous coated F75 alloy.
    Brown SA; Zhang K; Merritt K; Payer JH
    J Biomed Mater Res; 1993 Aug; 27(8):1007-17. PubMed ID: 8408113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The haemolytic action of particulate metals (Cd, Cr, Co, Fe, Mo, Ni, Ta, Ti, Zn, Co-Cr alloy).
    Rae T
    J Pathol; 1978 Jun; 125(2):81-9. PubMed ID: 722392
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion behaviour of the Co-Cr-Mo dental alloy in solutions of different composition and different pH values.
    Rincić N; Baucić I; Miko S; Papić M; Prohić E
    Coll Antropol; 2003; 27 Suppl 2():99-106. PubMed ID: 12971177
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Biodeterioration and corrosion of metallic implants and prostheses].
    López GD
    Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Release of metal ions from dental implant materials in vivo: determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue.
    Lugowski SJ; Smith DC; McHugh AD; Van Loon JC
    J Biomed Mater Res; 1991 Dec; 25(12):1443-58. PubMed ID: 1794994
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.