61 related articles for article (PubMed ID: 7391623)
1. [Study on design and metallic materials of the femoral stems of total hip prostheses (author's transl)].
Furukawa S
Nihon Seikeigeka Gakkai Zasshi; 1980 Feb; 54(2):177-90. PubMed ID: 7391623
[TBL] [Abstract][Full Text] [Related]
2. Fatigue fractures of the femoral component of Charnley and Charnley-Müller type total hip prostheses.
Ducheyne P; De Meester P; Aernoudt E; Martens M; Mulier JC
J Biomed Mater Res; 1975 Jul; 9(4):199-219. PubMed ID: 1176502
[TBL] [Abstract][Full Text] [Related]
3. [Study on the strength and microcleanliness of the stem of the total hip prostheses].
Mitsuda M
Nihon Seikeigeka Gakkai Zasshi; 1990 Jan; 64(1):56-69. PubMed ID: 2319193
[TBL] [Abstract][Full Text] [Related]
4. [A study of the stress distribution of the stem of the total hip prosthesis (author's transl)].
Tsunashima K
Nihon Seikeigeka Gakkai Zasshi; 1979 Jan; 53(1):65-84. PubMed ID: 429817
[TBL] [Abstract][Full Text] [Related]
5. Failed femoral stems in total hip prostheses. A report of six cases.
Galante JO; Rostoker W; Doyle JM
J Bone Joint Surg Am; 1975 Mar; 57(2):230-6. PubMed ID: 1112850
[TBL] [Abstract][Full Text] [Related]
6. [Shock absorption by intermediate hip prostheses].
Fabeck L; Vantomme J; Descamps PY; Zekhnini C; Hardy D; Delincé P
Rev Chir Orthop Reparatrice Appar Mot; 2001 Apr; 87(2):155-61. PubMed ID: 11319427
[TBL] [Abstract][Full Text] [Related]
7. The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic.
Cech O; Dzupa V
Acta Chir Orthop Traumatol Cech; 2005; 72(1):57-76. PubMed ID: 15860155
[TBL] [Abstract][Full Text] [Related]
8. Stem fractures of extra-heavy Cobra femoral hip prostheses. Report of two cases.
Marmor L; Gruen TA
Clin Orthop Relat Res; 1984 Nov; (190):148-53. PubMed ID: 6488624
[TBL] [Abstract][Full Text] [Related]
9. Femoral component loosening after total hip arthroplasty.
McBeath AA; Foltz RN
Clin Orthop Relat Res; 1979 Jun; (141):66-70. PubMed ID: 477126
[TBL] [Abstract][Full Text] [Related]
10. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses.
Ramos A; Simões JA
J Biomech; 2009 Nov; 42(15):2602-10. PubMed ID: 19660758
[TBL] [Abstract][Full Text] [Related]
11. Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings.
Clarke IC
Clin Orthop Relat Res; 1992 Sep; (282):19-30. PubMed ID: 1516312
[TBL] [Abstract][Full Text] [Related]
12. MR imaging of 22 Charnley-Müller total hip prostheses.
Lemmens JA; van Horn JR; den Boer J; van der Riet W; Ruijs JH
Rofo; 1986 Sep; 145(3):311-5. PubMed ID: 3020635
[TBL] [Abstract][Full Text] [Related]
13. Strategies for improving fixation of femoral components in total hip arthroplasty.
Poss R; Walker P; Spector M; Reilly DT; Robertson DD; Sledge CB
Clin Orthop Relat Res; 1988 Oct; (235):181-94. PubMed ID: 3416525
[TBL] [Abstract][Full Text] [Related]
14. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
Behairy YM; Harris WH
Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
[TBL] [Abstract][Full Text] [Related]
15. [Does the type of prosthesis have an effect on the development of periarticular ossification?].
Gierse H; Scherberich M; Fuchs S
Z Orthop Ihre Grenzgeb; 1994; 132(6):516-20. PubMed ID: 7831956
[TBL] [Abstract][Full Text] [Related]
16. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal.
Semlitsch M; Lehmann M; Weber H; Doerre E; Willert HG
J Biomed Mater Res; 1977 Jul; 11(4):537-52. PubMed ID: 559675
[TBL] [Abstract][Full Text] [Related]
17. [Should monobloc cemented stems be systematically revised during revision total hip arthroplasty? A prospective evaluation].
Grosjean G; Courpied JP; Moindreau M; Hunou N; Mathieu M; Hamadouche M
Rev Chir Orthop Reparatrice Appar Mot; 2008 Nov; 94(7):670-7. PubMed ID: 18984124
[TBL] [Abstract][Full Text] [Related]
18. Circumferential and axial strain in the proximal femur: effect of prosthesis type and position.
McBeath AA; Schopler SA; Narechania RG
Clin Orthop Relat Res; 1980; (150):301-5. PubMed ID: 7428236
[TBL] [Abstract][Full Text] [Related]
19. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
[TBL] [Abstract][Full Text] [Related]
20. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.
Incavo SJ; Johnson CC; Churchill DL; Beynnon BD
Am J Orthop (Belle Mead NJ); 2001 Apr; 30(4):323-7. PubMed ID: 11334454
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]