These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 7399376)

  • 1. Significance of skin metallization in the diagnosis of electrocution.
    Marcinkowski T; Pankowski M
    Forensic Sci Int; 1980; 16(1):1-6. PubMed ID: 7399376
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The macroscopic detection of metallization in the latent current mark.
    Pierucci G; Danesino P
    Z Rechtsmed; 1980; 85(2):97-105. PubMed ID: 7434980
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fluorescent technique for macroscopic detection of electrical metallization.
    Pierucci G; Danesino P
    Z Rechtsmed; 1981; 86(4):245-8. PubMed ID: 6789573
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Findings for current marks: histopathological examination and energy-dispersive X-ray spectroscopy of three cases.
    Tanaka N; Kinoshita H; Jamal M; Kumihashi M; Tsutsui K; Ameno K
    Leg Med (Tokyo); 2013 Sep; 15(5):283-7. PubMed ID: 23895763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnosis of electrocution: The application of scanning electron microscope and energy-dispersive X-ray spectroscopy in five cases.
    Visonà SD; Chen Y; Bernardi P; Andrello L; Osculati A
    Forensic Sci Int; 2018 Mar; 284():107-116. PubMed ID: 29408719
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of metallization with energy-dispersive X-ray fluorescent spectrometry in experimental electric injury.
    Tanaka N; Kinoshita H; Jamal M; Ito A; Yamashita T; Nagata K; Miyatake N
    Leg Med (Tokyo); 2020 Nov; 47():101768. PubMed ID: 32738701
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Death or injury caused by electrocution.
    Wright RK
    Clin Lab Med; 1983 Jun; 3(2):343-53. PubMed ID: 6617121
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of atomic absorption spectroscopy for detection of multimetal traces in low-voltage electrical marks.
    Jakubeniene M; Zakaras A; Minkuviene ZN; Benoshys A
    Forensic Sci Int; 2006 Aug; 161(1):36-40. PubMed ID: 16314061
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Detection of metal traces in electric marks].
    Logemann E; Raule P; Hellerich U; Krützfeldt B
    Arch Kriminol; 1995; 196(5-6):156-64. PubMed ID: 8585785
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Study on electrical current mark with environmental scanning electron microscopy and energy dispersive X-ray microanalyser].
    Liu D; Wang H; Li SX; Ma XT; Duan YJ; Zhou HY; Zhou YW
    Fa Yi Xue Za Zhi; 2010 Dec; 26(6):421-4. PubMed ID: 21425602
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Metallization at the Exit Wound-An Unusual Finding in Fatal Electrocution.
    Ateriya N; Meshram VP; Kanchan T; Saraf A; Shekhawat RS; Malik S
    J Forensic Sci; 2020 Jan; 65(1):318-322. PubMed ID: 31433869
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Death by electrocution: Histological technique for copper detection on the electric mark.
    Bellini E; Gambassi G; Nucci G; Benvenuti M; Landi G; Gabbrielli M; Vanezis P
    Forensic Sci Int; 2016 Jul; 264():24-7. PubMed ID: 27015155
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrical Injuries in Animals: Causes, Pathogenesis, and Morphological Findings.
    Schulze C; Peters M; Baumgärtner W; Wohlsein P
    Vet Pathol; 2016 Sep; 53(5):1018-29. PubMed ID: 27106738
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A case of accidental electrocution. Identification of metallization on the electric marks with an energy dispersive X-ray microanalyzer].
    Tomita M; Ijiri I; Shimosato K; Mikami Y; Doi Y; Uehira K
    Nihon Hoigaku Zasshi; 1984 Feb; 38(1):59-63. PubMed ID: 6471574
    [No Abstract]   [Full Text] [Related]  

  • 15. The application of a variable-pressure scanning electron microscope with energy dispersive X-ray microanalyser to the diagnosis of electrocution: a case report.
    Kinoshita H; Nishiguchi M; Ouchi H; Minami T; Kubota A; Utsumi T; Sakamoto N; Kashiwagi N; Shinomiya K; Tsuboi H; Hishida S
    Leg Med (Tokyo); 2004 Mar; 6(1):55-60. PubMed ID: 15177075
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of Microbeam X-Ray Fluorescence Spectrometry in the Diagnosis of Suspected Electrocution by High-Voltage Direct Current: A Case Report.
    Wang T; Zou D; Zhang J; Chen Y
    Am J Forensic Med Pathol; 2016 Sep; 37(3):190-3. PubMed ID: 27333432
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Pathomorphological constellation in death resulting from high voltage electricity].
    Pollak S
    Arch Kriminol; 1980; 165(1-2):1-16. PubMed ID: 7387321
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Studies of the marks left by electric current as a function of current intensity and duration of contact. I. Metal and temperature determination].
    Sellier K
    Dtsch Z Gesamte Gerichtl Med; 1966; 57(1):161-5. PubMed ID: 5987907
    [No Abstract]   [Full Text] [Related]  

  • 19. Electrothermic damage to the nail due to arcing in high-voltage discharge.
    Bielefeld L; Mierdel K; Pollak S; Perdekamp MG
    Forensic Sci Int; 2013 Dec; 233(1-3):149-53. PubMed ID: 24314514
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of 4 Cases of Electrocution due to Direct Current Electronic Hunter.
    Zhu LL; Tong F; Liang Y; Lopsong TZ; Huang WS; Liu YL; Zhou YW
    Fa Yi Xue Za Zhi; 2019 Oct; 35(5):592-595. PubMed ID: 31833295
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.