These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

75 related articles for article (PubMed ID: 7404478)

  • 21. Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.
    Adcock DM; Johnston M
    Thromb Haemost; 2002 Jan; 87(1):74-9. PubMed ID: 11848460
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of concentration of trisodium citrate anticoagulant on calculation of the International Normalised Ratio and the International Sensitivity Index of thromboplastin.
    Duncan EM; Casey CR; Duncan BM; Lloyd JV
    Thromb Haemost; 1994 Jul; 72(1):84-8. PubMed ID: 7974381
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Reliability of laboratory tests for the control of oral anticoagulation. A comparative study of homemade human brain thromboplastin, the British comparative thromboplastin, simplastin, simplastin A, and thrombotest.
    Loeliger EA; Boekhout-Mussert JM; van Halem-Visser LP; Habbema JD; de Jonge H
    Thromb Diath Haemorrh; 1974 Dec; 32(2-3):483-91. PubMed ID: 4450200
    [No Abstract]   [Full Text] [Related]  

  • 24. No deterioration after 13 years in a stability study of a rabbit brain, plain, thromboplastin, RBT 1010, in rubber-stoppered ampoules.
    Stevenson KJ; Craig S; Goodman L; Kanyike FB
    Br J Haematol; 2004 Apr; 125(2):240-2. PubMed ID: 15059148
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins.
    Poller L; van den Besselaar AM; Jespersen J; Tripodi A; Houghton D
    Thromb Haemost; 1998 Oct; 80(4):615-23. PubMed ID: 9798981
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thromboplastin standardisation: calibrated lyophilised plasmas and coagulometer-specific international sensitivity indices.
    Dunford SR
    Br J Biomed Sci; 1998 Dec; 55(4):276-80. PubMed ID: 10436545
    [TBL] [Abstract][Full Text] [Related]  

  • 27. European concerted action on anticoagulation. Minimum numbers of lyophilized plasma samples for ISI calibration of CoaguChek and TAS point-of-care whole blood prothrombin time monitors.
    Poller L; Keown M; Chauhan N; van den Besselaar AM; Tripodi A; Jespersen J; Shiach C
    Am J Clin Pathol; 2003 Feb; 119(2):232-40. PubMed ID: 12579993
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A comparison of INRs after local calibration of thromboplastin international sensitivity indexes.
    McGlasson DL
    Clin Lab Sci; 2002; 15(2):91-5. PubMed ID: 12776770
    [TBL] [Abstract][Full Text] [Related]  

  • 29. International standardization of laboratory control of oral anticoagulant therapy: a survey of thromboplastin reagents used for prothrombin time testing.
    van den Besselaar AM
    J Heart Valve Dis; 1993 Jan; 2(1):42-52. PubMed ID: 8269109
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of instrumentation on thromboplastin calibration.
    Chantarangkul V; Tripodi A; Mannucci PM; Bonomi AB
    Thromb Haemost; 1992 May; 67(5):588-9. PubMed ID: 1519221
    [No Abstract]   [Full Text] [Related]  

  • 31. International collaborative study for the calibration of a proposed international standard for thromboplastin, rabbit, plain.
    Chantarangkul V; van den Besselaar AM; Witteveen E; Tripodi A
    J Thromb Haemost; 2006 Jun; 4(6):1339-45. PubMed ID: 16706980
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the international normalized ratio?
    Tripodi A; Arbini AA; Chantarangkul V; Bettega D; Mannucci PM
    Thromb Haemost; 1993 Dec; 70(6):921-4. PubMed ID: 8165612
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Standardizing the prothrombin time. Calibrating coagulation instruments as well as thromboplastin.
    Becker DM; Humphries JE; Walker FB; DeMong LK; Bopp JS; Acker MN
    Arch Pathol Lab Med; 1993 Jun; 117(6):602-5. PubMed ID: 8503731
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Freeze-dried whole plasma: evaluating sucrose, trehalose, sorbitol, mannitol and glycine as stabilizers.
    Bakaltcheva I; O'Sullivan AM; Hmel P; Ogbu H
    Thromb Res; 2007; 120(1):105-16. PubMed ID: 16962645
    [TBL] [Abstract][Full Text] [Related]  

  • 35. French multicentric evaluation of recombinant tissue factor (recombiplastin) for determination of prothrombin time.
    Roussi J; Drouet L; Samama M; SiƩ P
    Thromb Haemost; 1994 Nov; 72(5):698-704. PubMed ID: 7900077
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Correction for lack of coincidence of normal and abnormal calibration slopes in ISI determination.
    Poller L; van den Besselaar AM; Jespersen J; Tripodi A; Houghton D
    Thromb Haemost; 1999 Jun; 81(6):935-9. PubMed ID: 10404771
    [TBL] [Abstract][Full Text] [Related]  

  • 37. International collaborative study for the calibration of a proposed reference preparation for thromboplastin, human recombinant, plain. On behalf of the Subcommittee on Control of Anticoagulation.
    Tripodi A; Chantarangkul V; Negri B; Clerici M; Mannucci PM
    Thromb Haemost; 1998 Feb; 79(2):439-43. PubMed ID: 9493604
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of the International Sensitivity Index of a new near-patient testing device to monitor oral anticoagulant therapy--overview of the assessment of conformity to the calibration model.
    Tripodi A; Chantarangkul V; Clerici M; Negri B; Mannucci PM
    Thromb Haemost; 1997 Aug; 78(2):855-8. PubMed ID: 9268184
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of INRs determined with a whole blood prothrombin time device and two international reference preparations for thromboplastin.
    van den Besselaar AM
    Thromb Haemost; 2000 Sep; 84(3):410-2. PubMed ID: 11019963
    [TBL] [Abstract][Full Text] [Related]  

  • 40. College of American Pathologists Conference XXXI on laboratory monitoring of anticoagulant therapy: laboratory monitoring of oral anticoagulant therapy.
    Fairweather RB; Ansell J; van den Besselaar AM; Brandt JT; Bussey HI; Poller L; Triplett DA; White RH
    Arch Pathol Lab Med; 1998 Sep; 122(9):768-81. PubMed ID: 9740135
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.