  • 1. Ignition of an endotracheal tube during laser microsurgery.
    Hirshman CA; Leon D
    Anesthesiology; 1980 Aug; 53(2):177. PubMed ID: 7416530
    [No Abstract]   [Full Text] [Related]  

  • 2. Endotracheal tube ignition during laser surgery of the larynx.
    Burgess GE; LeJeune FE
    Arch Otolaryngol; 1979 Sep; 105(9):561-2. PubMed ID: 573110
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Ignition of the endotracheal tube during CO2 laser therapy of upper airway disorders].
    Munksgaard AB; Bonde J; Valentin N
    Ugeskr Laeger; 1991 Jun; 153(25):1805. PubMed ID: 1906652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Indirect ignitioin of the endotracheal tube during carbon dioxide laser surgery.
    Hirshman CA; Smith J
    Arch Otolaryngol; 1980 Oct; 106(10):639-41. PubMed ID: 7417094
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endotracheal tube ignition during the intratracheal laser treatment.
    Komatsu T; Kaji R; Okazaki S; Miyawaki I; Ishihara K; Takahashi Y
    Asian Cardiovasc Thorac Ann; 2008 Dec; 16(6):e49-51. PubMed ID: 18984745
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prevention of fire hazard during laser microsurgery.
    Kumar A; Frost E
    Anesthesiology; 1981 Apr; 54(4):350. PubMed ID: 7212341
    [No Abstract]   [Full Text] [Related]  

  • 7. Injuries to the bronchi and lungs caused by laser-ignited endotracheal tube fires.
    Duncavage JA; Ossoff RH; Rouman WC; Toohill RJ; Almagro UA; Carl GA; Aronson S
    Otolaryngol Head Neck Surg; 1984 Dec; 92(6):639-43. PubMed ID: 6440081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Indirect ignition of the endotracheal tube and the elastic part of the bronchofiberscope during endoscopic laser surgery].
    Hakutou T; Sirae A; Tanaka K; Michigami M; Akutagawa T; Kimura K; Inamori K; Hyoudou M
    Masui; 1983 Mar; 32(3):343-7. PubMed ID: 6864999
    [No Abstract]   [Full Text] [Related]  

  • 9. Positive end-expiratory pressure lowers the risk of laser-induced polyvinylchloride tracheal-tube fires.
    Pashayan AG; SanGiovanni C; Davis LE
    Anesthesiology; 1993 Jul; 79(1):83-7. PubMed ID: 8342831
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tracheostomy tube ignition during microlaryngeal surgery using diode laser: a case report.
    Wang HM; Lee KW; Tsai CJ; Lu IC; Kuo WR
    Kaohsiung J Med Sci; 2006 Apr; 22(4):199-202. PubMed ID: 16679303
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ignition of a tracheal tube during laryngeal laser surgery.
    Vourc'h G; Tannieres M; Freche G
    Anaesthesia; 1979; 34(7):685. PubMed ID: 517732
    [No Abstract]   [Full Text] [Related]  

  • 12. Effect of extraluminal oxygen on carbon dioxide laser ignition of endotracheal tubes.
    Arnold JE; Allphin AL
    Arch Otolaryngol Head Neck Surg; 1992 Jul; 118(7):722-4. PubMed ID: 1627293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Experimental studies of the danger of ignition of tubes during endolaryngeal microsurgery with the laser].
    Fischer PL; Dinstl K
    HNO; 1985 Mar; 33(3):134-7. PubMed ID: 3997574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The oxygen and nitrous oxide indices of flammability of endotracheal tubes determined by laser ignition.
    Simpson JI; Wolf GL; Rosen A; Krespi Y; Schiff GA
    Laryngoscope; 1991 Sep; 101(9):981-4. PubMed ID: 1886447
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On the development of a new laser-resistant endotracheal tube.
    Sosis MB
    J Clin Anesth; 1992; 4(2):87-8. PubMed ID: 1562341
    [No Abstract]   [Full Text] [Related]  

  • 16. A comparison of CO2 laser ignition of the Xomed, plastic, and rubber endotracheal tubes.
    Sosis MB; Dillon FX
    Anesth Analg; 1993 Feb; 76(2):391-3. PubMed ID: 8424521
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Experiences with a non-inflammable tube in laser surgery of the larynx].
    Pramesberger G; Fischer PL; Benke A; Glaninger J
    Anaesthesist; 1985 Nov; 34(11):636-7. PubMed ID: 4091251
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Saline soaked pledgets prevent CO2 laser induced tracheal tube cuff ignition.
    Sosis M
    Can J Anaesth; 1990 May; 37(4 Pt 2):S72. PubMed ID: 2361311
    [No Abstract]   [Full Text] [Related]  

  • 19. Laser-induced endotracheal tube fire.
    Cozine K; Rosenbaum LM; Askanazi J; Rosenbaum SH
    Anesthesiology; 1981 Nov; 55(5):583-5. PubMed ID: 7294415
    [No Abstract]   [Full Text] [Related]  

  • 20. Fires of endotracheal tubes of three different materials during carbon dioxide laser surgery.
    Lai HC; Juang SE; Liu TJ; Ho WM
    Acta Anaesthesiol Sin; 2002 Mar; 40(1):47-51. PubMed ID: 11989049
    [TBL] [Abstract][Full Text] [Related]  