BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 7416953)

  • 1. Stump pressure: an unreliable guide for shunting during carotid endarterectomy.
    Kwaan JH; Peterson GJ; Connolly JE
    Arch Surg; 1980 Sep; 115(9):1083-6. PubMed ID: 7416953
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved results with carotid endarterectomy.
    Connolly JE; Kwaan JH; Stemmer EA
    Ann Surg; 1977 Sep; 186(3):334-42. PubMed ID: 889376
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Carotid artery stump pressure and associated neurological changes in predominantly symptomatic carotid artery disease patients undergoing awake carotid endarterectomy.
    Mulaudzi TV; Biccard BM; Robbs JV; Paruk N; Pillay B; Rajaruthnam P
    Cardiovasc J Afr; 2009; 20(2):116-8. PubMed ID: 19421646
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Near-infrared spectroscopy as a predictor of cerebral ischaemia during carotid endarterectomy in awake patients.
    Inčiūra D; Antuševas A; Aladaitis A; Gimžauskaitė A; Velička L; Kavaliauskienė Ž
    Vascular; 2020 Jun; 28(3):301-308. PubMed ID: 31937208
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cerebral Neuromonitoring during Carotid Endarterectomy and Impact of Contralateral Internal Carotid Occlusion.
    Sef D; Skopljanac-Macina A; Milosevic M; Skrtic A; Vidjak V
    J Stroke Cerebrovasc Dis; 2018 May; 27(5):1395-1402. PubMed ID: 29397311
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimal cerebral monitoring during carotid endarterectomy: neurologic response under local anesthesia.
    Evans WE; Hayes JP; Waltke EA; Vermilion BD
    J Vasc Surg; 1985 Nov; 2(6):775-7. PubMed ID: 4057434
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Failure of carotid stump pressures. Its incidence as a predictor for a temporary shunt during carotid endarterectomy.
    Kelly JJ; Callow AD; O'Donnell TF; McBride K; Ehrenberg B; Korwin S; Welch H; Gembarowicz RM
    Arch Surg; 1979 Dec; 114(12):1361-6. PubMed ID: 534456
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlation of carotid artery stump pressure and neurologic changes during 474 carotid endarterectomies performed in awake patients.
    Calligaro KD; Dougherty MJ
    J Vasc Surg; 2005 Oct; 42(4):684-9. PubMed ID: 16242555
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Carotid endarterectomy. The unreliability of intraoperative monitoring in patients having had stroke or reversible ischemic neurologic deficit.
    Rosenthal D; Stanton PE; Lamis PA
    Arch Surg; 1981 Dec; 116(12):1569-75. PubMed ID: 7316754
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carotid endarterectomy in the awake patient.
    Connolly JE
    Am J Surg; 1985 Jul; 150(1):159-65. PubMed ID: 4014567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical validation of 40-mmHg carotid stump pressure for patients undergoing carotid endarterectomy under general anesthesia.
    Shahidi S; Owen-Falkenberg A; Gottschalksen B
    J Cardiovasc Surg (Torino); 2017 Jun; 58(3):431-438. PubMed ID: 24918194
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A retrospective comparison of the use of shunts during carotid endarterectomy.
    Hertzer NR; Beven EG
    Surg Gynecol Obstet; 1980 Jul; 151(1):81-4. PubMed ID: 6770477
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy.
    Lee TS; Hines GL; Feuerman M
    Ann Vasc Surg; 2008 Jan; 22(1):58-62. PubMed ID: 18023554
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Internal carotid artery stump pressure and cerebral blood flow during carotid endarterectomy: modification by halothane, enflurane, and innovar.
    McKay RD; Sundt TM; Michenfelder JD; Gronert GA; Messick JM; Sharbrough FW; Piepgras DG
    Anesthesiology; 1976 Oct; 45(4):390-9. PubMed ID: 973690
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A prospective study of carotid endarterectomy with and without shunt.
    Ahmad W; Hoffman TH; Fry DE; Harbrecht PJ
    Am Surg; 1981 Jan; 47(1):14-8. PubMed ID: 7469170
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prediction of cerebral ischemic tolerance during carotid cross-clamping by angiographic criteria.
    Aleksic M; Gawenda M; Heckenkamp J; Matoussevitch V; Coburger S; Brunkwall J
    Eur J Vasc Endovasc Surg; 2004 Jun; 27(6):640-5. PubMed ID: 15121116
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective single-center study on the reliability of ipsilateral cerebral oximetry using near-infrared spectroscopy as a predictor for selective shunting during carotid endarterectomy.
    Alhaizaey A; Yousif M; Azazy A; Saber A; Safan M; Elgamal GA; Almalki Y; Alhazmi B
    Vascular; 2024 Jan; ():17085381231214596. PubMed ID: 38281943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stump pressure, electroencephalographic changes, and the contralateral carotid artery: another look at selective shunting.
    Harada RN; Comerota AJ; Good GM; Hashemi HA; Hulihan JF
    Am J Surg; 1995 Aug; 170(2):148-53. PubMed ID: 7631920
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation of intraoperative collateral perfusion pressure during carotid endarterectomy and status of the contralateral carotid artery and collateral cerebral blood flow.
    AbuRahma AF; Mousa AY; Stone PA; Hass SM; Dean LS; Keiffer T
    Ann Vasc Surg; 2011 Aug; 25(6):830-6. PubMed ID: 21680143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Selective shunting for carotid endarterectomy in patients with recent stroke.
    Hans SS; Catanescu I
    J Vasc Surg; 2015 Apr; 61(4):915-9. PubMed ID: 25601503
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.