139 related articles for article (PubMed ID: 7418639)
1. [A special glass electrode for pH-measurements on biological tissues].
Mokros W
Dtsch Z Verdau Stoffwechselkr; 1980; 40(1):13-7. PubMed ID: 7418639
[TBL] [Abstract][Full Text] [Related]
2. Intraoperative pH of the gastric mucosa before and after truncal vagotomy in the dog. The Grassi test.
Larsson JO
Scand J Gastroenterol; 1984 Jan; 19(1):65-70. PubMed ID: 6710079
[TBL] [Abstract][Full Text] [Related]
3. A single intragastric pH electrode does not accurately measure intragastric acidity.
Fisher RS; Sher DJ; Donahue D; Senior J; Krevsky B
Am J Gastroenterol; 1996 Jun; 91(6):1167-72. PubMed ID: 8651165
[TBL] [Abstract][Full Text] [Related]
4. Basic principles of pH registration.
Emde C; Hopert R; Riecken EO
Neth J Med; 1989 Mar; 34 Suppl():S3-9. PubMed ID: 2725802
[TBL] [Abstract][Full Text] [Related]
5. Assessment of gastric secretory function by 24-hour pH-metry in patients with hepatic cirrhosis due to HBV infection, before and after non-shunt type Sugiura procedure.
Orłowski M
Med Sci Monit; 2003 Aug; 9 Suppl 3():55-9. PubMed ID: 15156614
[TBL] [Abstract][Full Text] [Related]
6. 24-h recording of intragastric pH: technical aspects and clinical relevance.
van Herwaarden MA; Samsom M; Smout AJ
Scand J Gastroenterol Suppl; 1999; 230():9-16. PubMed ID: 10499456
[TBL] [Abstract][Full Text] [Related]
7. [Direct measurement of pH in the stomach in situ with a glass electrode with recording of the secretion curve].
Madzarovová-Nohejlová ; Musil F; Tvrzký J; Snajdr S
Cesk Gastroenterol Vyz; 1969 Mar; 23(2):57-65. PubMed ID: 5768478
[No Abstract] [Full Text] [Related]
8. [A pH-probe for endoscopic parietal topographical pH-metry].
Iakovleva GA; Dubinskaia TK
Med Tekh; 2006; (1):35-8. PubMed ID: 16610286
[TBL] [Abstract][Full Text] [Related]
9. [Intraoperative measurement of gastric mucosa pH as a criterion of the radicality of vagotomy].
Jedrzejczyk W; Tomaszewski J; Buczkowski M; Peterlejtner R
Pol Przegl Chir; 1977 Jul; 49(7):691-5. PubMed ID: 19733
[No Abstract] [Full Text] [Related]
10. Development of a miniature pH glass electrode for biological applications.
Ahn BK; Liu CC; Neuman MR; Ko WH
Biomed Sci Instrum; 1971; 8():81-2. PubMed ID: 5146943
[No Abstract] [Full Text] [Related]
11. [New approaches to gastric ph-metry].
Leia IuIa
Klin Med (Mosk); 2005; 83(11):65-9. PubMed ID: 16404944
[TBL] [Abstract][Full Text] [Related]
12. [Modern evaluation of the accuracy of determination of the acid-forming function of the stomach by the method of intragastric pH-metry].
Iakovlev GA
Med Tekh; 2004; (6):20-3. PubMed ID: 15656410
[TBL] [Abstract][Full Text] [Related]
13. [Influence of gastric juice pH on the metabolism of vitamin C in gastric mucosa and juice].
Safranow K; Korzonek M; Dziedziejko V; Jakubowska K; Sulzyc-Bielicka V; Domański L; Ciechanowski K; Chlubek D
Pol Merkur Lekarski; 2006 Feb; 20(116):168-72. PubMed ID: 16708632
[TBL] [Abstract][Full Text] [Related]
14. Regional differences in gastric acidity and antacid distribution: is a single pH electrode sufficient?
Fisher RS; Sher DJ; Donahue D; Knight LC; Maurer A; Urbain JL; Krevsky B
Am J Gastroenterol; 1997 Feb; 92(2):263-70. PubMed ID: 9040203
[TBL] [Abstract][Full Text] [Related]
15. A pH-glass electrode for nanolitre biological samples.
Karlmark B; Sohtell M; Ulfendahl HR
Acta Soc Med Ups; 1971; 76(1-2):58-62. PubMed ID: 5134184
[No Abstract] [Full Text] [Related]
16. Relation between interleukin-1beta messenger RNA in gastric fundic mucosa and gastric juice pH in patients infected with Helicobacter pylori.
Wang M; Furuta T; Takashima M; Futami H; Shirai N; Hanai H; Kaneko E
J Gastroenterol; 1999; 34 Suppl 11():10-7. PubMed ID: 10616759
[TBL] [Abstract][Full Text] [Related]
17. [Review of pH measurement (4): pH meter and glass electrode Q & A].
Ueda Y
Tanpakushitsu Kakusan Koso; 1998 May; 43(6):799-804. PubMed ID: 9612074
[No Abstract] [Full Text] [Related]
18. [Review of pH measurement (3): Practice of pH meter based on glass electrode method (2)].
Ohkawa H
Tanpakushitsu Kakusan Koso; 1998 Apr; 43(5):711-5. PubMed ID: 9564788
[No Abstract] [Full Text] [Related]
19. Slimline vs. glass pH electrodes: what degree of accuracy should we expect?
Pandolfino JE; Ghosh S; Zhang Q; Heath M; Bombeck T; Kahrilas PJ
Aliment Pharmacol Ther; 2006 Jan; 23(2):331-40. PubMed ID: 16393314
[TBL] [Abstract][Full Text] [Related]
20. [Review of pH measurement (2): Practice of pH meter based on glass electrode method].
Ohkawa H
Tanpakushitsu Kakusan Koso; 1998 Mar; 43(3):272-80. PubMed ID: 9528359
[No Abstract] [Full Text] [Related]
[Next] [New Search]