These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 7421089)

  • 1. [Theoretical and practical aspects of removal of ferromagnetic foreign bodies from the interior of the eyeball (author's transl)].
    Szaflik J
    Klin Oczna; 1980 Jul; 82(7):373-4. PubMed ID: 7421089
    [No Abstract]   [Full Text] [Related]  

  • 2. [Removal of non-magnetic foreign bodies from the anterior chamber by a microsurgical method (author's transl)].
    Krwawicz L
    Klin Oczna; 1978 May; 48(5):223-5. PubMed ID: 672125
    [No Abstract]   [Full Text] [Related]  

  • 3. [Practical instructions for removal of ferromagnetic foreign bodies from the eye].
    Kotania W; Cichoń J
    Klin Oczna; 1992; 94(2-3):69-70. PubMed ID: 1640687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A new permanent magnet for removal of intra-ocular ferromagnetic foreign bodies].
    Kuhn F; Heimann K
    Klin Monbl Augenheilkd; 1991 Apr; 198(4):301-3. PubMed ID: 1861409
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [An intra-ocular electromagnet (author's transl)].
    Buffet JM; Czekaj R
    J Fr Ophtalmol; 1981; 4(6-7):509-10. PubMed ID: 7299068
    [No Abstract]   [Full Text] [Related]  

  • 6. [Foreign bodies in the posterior pole of the eye].
    Mierzejewski A; Kałuzny J
    Klin Oczna; 1987 Jan; 89(1):6-8. PubMed ID: 3613461
    [No Abstract]   [Full Text] [Related]  

  • 7. Magnetized instrument removal of foreign body through the pars plana.
    Bennett TO; Diddie KR; Trolinger K
    Ophthalmic Surg; 1981 Jun; 12(6):432-4. PubMed ID: 7266987
    [No Abstract]   [Full Text] [Related]  

  • 8. A 20-gauge intraocular electromagnetic tip for simplified intraocular foreign-body extraction.
    May DR; Noll FG; Munoz R
    Arch Ophthalmol; 1989 Feb; 107(2):281-2. PubMed ID: 2916983
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Use of alternating magnetic field for removal of non-magnetic metallic foreign bodies].
    Gundorova RA; Shteĭnshleĭger VB; Malaev AA; El'kind SA; Iuzhakov AM
    Vestn Oftalmol; 1975; (5):41-3. PubMed ID: 1235199
    [No Abstract]   [Full Text] [Related]  

  • 10. [Measuring procedure for the determination of the location, nature and size of metallic foreign objects in the eye by means of an electromagnetic sensor (author's transl)].
    Hartmann H; Bramm G
    Klin Monbl Augenheilkd; 1980 Nov; 177(5):643-8. PubMed ID: 7253521
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Treatment of penetrating wounds of the eyeball].
    Tiratsuian GKh
    Voen Med Zh; 1972 May; 5():70-2. PubMed ID: 4662909
    [No Abstract]   [Full Text] [Related]  

  • 12. [Surgical removal of intravitreous floating foreign bodies (author's transl)].
    Yang JC
    Zhonghua Yan Ke Za Zhi; 1982 Mar; 18(2):78-80. PubMed ID: 6807651
    [No Abstract]   [Full Text] [Related]  

  • 13. [Diagnostic and therapeutic indications for the Berman locating device].
    Perdriel G; Vignat JP; Baltenneck A; Terzian M
    Bull Soc Ophtalmol Fr; 1974 Jan; 74(1):37-41. PubMed ID: 4430071
    [No Abstract]   [Full Text] [Related]  

  • 14. ["Magnetic induction rod" method for removal of intraocular foreign bodies (author's transl)].
    Zhang XF
    Zhonghua Yan Ke Za Zhi; 1982 Mar; 18(2):74-7. PubMed ID: 6807650
    [No Abstract]   [Full Text] [Related]  

  • 15. [Microsurgical technic of foreign body removal from the posterior part of the eye].
    Bykov VP; Malaev AA
    Vestn Oftalmol; 1978; (3):33-4. PubMed ID: 685019
    [No Abstract]   [Full Text] [Related]  

  • 16. [Importance and limitations of the electromagnetic localization for extraction of intraocular foreign bodies].
    Bourgeois H; Vignat JP; Pon A; Jacob H; Jacquiot P; Maurin JF
    Bull Mem Soc Fr Ophtalmol; 1983; 95():113-6. PubMed ID: 6677291
    [No Abstract]   [Full Text] [Related]  

  • 17. [Removal of magnetic intra-ocular foreign bodies through incision over the pars plana (author's transl)].
    Zang Q
    Zhonghua Yan Ke Za Zhi; 1981 Sep; 17(5):299-300. PubMed ID: 6800744
    [No Abstract]   [Full Text] [Related]  

  • 18. [Treatment of intraocular foreign bodies in the posterior segment resistant to electromagnetic localization].
    Trepsat C; Ravault MP; Chabin T
    Bull Mem Soc Fr Ophtalmol; 1983; 95():141-3. PubMed ID: 6677298
    [No Abstract]   [Full Text] [Related]  

  • 19. [A simple lid retractor for examinations at the slit lamp and for the removal of corneal foreign bodies (author's transl)].
    Schmidt T
    Klin Monbl Augenheilkd; 1973 Jun; 162(6):825-6. PubMed ID: 4745904
    [No Abstract]   [Full Text] [Related]  

  • 20. [Metallic intraocular foreign body extraction by primary vitrectomy and microforceps].
    Gribomont AC; De Hosté F
    Bull Soc Belge Ophtalmol; 1996; 262():129-34. PubMed ID: 9376916
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.