These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 7423216)

  • 1. [Types of pathomorphological changes in the heart caused by cardiostimulating electrodes].
    Lysenková A
    Soud Lek; 1980; 25 Suppl 3():39-43. PubMed ID: 7423216
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium.
    Mase H; Tamura K; Hiromoto A; Hotta M; Hotomi S; Togashi M; Fukuda Y; Yajima T; Nitta T; Tanaka S; Sugisaki Y
    J Nippon Med Sch; 2005 Feb; 72(1):52-9. PubMed ID: 15834208
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Adherence of pacemaker electrodes to the endomyocardium--a postmortem study].
    Brunner P; Götz M; Warich-Eitel S
    Versicherungsmedizin; 1992 Feb; 44(1):3-7. PubMed ID: 1570671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. The role of electrode design.
    Lee ME; Chaux A; Matloff JM
    J Thorac Cardiovasc Surg; 1977 Sep; 74(3):433-5. PubMed ID: 895177
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Extraction of tricuspid valve tissue and myocardium as a complication of transvenous cardiac pacing (author's transl)].
    Köhler F; Schmitt CG; Ellringmann U
    Thoraxchir Vask Chir; 1977 Apr; 25(2):97-100. PubMed ID: 300918
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The morphological conditions of the permanent pacemaker lead extraction.
    Kozłowski D; Dubaniewicz A; Koźluk E; Grzybiak M; Krupa W; Kołodziej P; Pazdyga A; Adamowicz-Kornacka M; Walczak E; Walczak F
    Folia Morphol (Warsz); 2000; 59(1):25-9. PubMed ID: 10774088
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Histological examination of the endocardium at the contact points with intracardially implanted pacemaker electrodes].
    Heymer B; Wuttke H; Kreutzberg B
    Thoraxchir Vask Chir; 1969 Feb; 17(1):59-67. PubMed ID: 5271617
    [No Abstract]   [Full Text] [Related]  

  • 8. [Cardiac rupture in myocardial infarcts associated with the use of pacemakers with transthoracic electrode].
    Moragrega Adame JL; Contreras Rodríguez R
    Arch Inst Cardiol Mex; 1973; 43(1):155-60. PubMed ID: 4696396
    [No Abstract]   [Full Text] [Related]  

  • 9. [Roentgenographic findings in patients with pacemakers (author's transl)].
    du Mesnil de Rochemont W
    Rontgenblatter; 1976 Jan; 29(1):5-12. PubMed ID: 1251123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anatomo-pathological changes in the endocardial permanent pacemaking and their clinical importance.
    Camerini F; Giarelli L; Crepaldi L; Scardi S; Silvestri F
    G Ital Cardiol; 1971; 1(5):409-21. PubMed ID: 5132625
    [No Abstract]   [Full Text] [Related]  

  • 11. Histological reactions of porous tip endocardial electrodes implanted in sheep.
    Guarda F; Galloni M; Assone F; Pasteris V; Luboz MP
    Int J Artif Organs; 1982 Jul; 5(4):267-73. PubMed ID: 7118289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Pathological observations on patients carrying pacemakers and clinical consequences. Reports of 105 observed cases (author's transl)].
    Giarelli L; Silvestri F; Pivotti F
    G Ital Cardiol; 1978; 8 Suppl 1():299-301. PubMed ID: 754969
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac pathology of transvenous pacemakers.
    Huang TY; Baba N
    Am Heart J; 1972 Apr; 83(4):469-74. PubMed ID: 5041834
    [No Abstract]   [Full Text] [Related]  

  • 14. Studies of the tissue reaction induced by transvenous pacemaker electrodes. I. Microscopic examination of the extent of connective tissue around the electrode tip in the human right ventricle.
    Beyersdorf F; Schneider M; Kreuzer J; Falk S; Zegelman M; Satter P
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1753-9. PubMed ID: 2463544
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The porous-surfaced electrode: a new concept in pacemaker lead design.
    MacGregor DC; Wilson GJ; Lixfeld W; Pilliar RM; Bobyn JD; Silver MD; Smardon S; Miller SL
    J Thorac Cardiovasc Surg; 1979 Aug; 78(2):281-91. PubMed ID: 459536
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Histological findings around electrodes in pacemaker and implantable cardioverter-defibrillator patients: comparison of steroid-eluting and non-steroid-eluting electrodes.
    Dvorak P; Novak M; Kamaryt P; Slana B; Lipoldova J; Dvorak P
    Europace; 2012 Jan; 14(1):117-23. PubMed ID: 21893512
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Subepicardial infarction, myocardial impression, and ventricular penetration by sutureless electrode and leads.
    Steinke WE; Thomas FT; ul Hassan Z; Mendoza RA; Gear AS
    Chest; 1976 Jul; 70(1):80-1. PubMed ID: 1277940
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac pathology of transvenous pacemakers in dogs.
    Fishbein MC; Tan KS; Beazell JW; Schulman JH; Hirose FM; Criley JM
    Am Heart J; 1977 Jan; 93(1):73-81. PubMed ID: 318794
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Morphological changes on the myocardium and vasular wall following electric stimulation of the heart using myocardial and transvenous intracardial electrodes].
    Hager W; Hienz HA; Düwell HJ
    Thoraxchir Vask Chir; 1968 Apr; 16(2):143-60. PubMed ID: 5242911
    [No Abstract]   [Full Text] [Related]  

  • 20. [Extraction of the electrodes by continuous traction--an effective procedure in treating pacemaker wearers with secondary inflammatory complications].
    Thiele G; Lachmann W; Bredel P; Daniel E
    Z Gesamte Inn Med; 1985 Dec; 40(24):705-7. PubMed ID: 4096053
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.