These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 7428181)

  • 1. Evaluation of serum creatinine measurement by the direct acidification method for errors contributed by non-creatinine chromogens.
    Lolekha PH; Taksinamanee R
    Clin Chim Acta; 1980 Oct; 107(1-2):97-104. PubMed ID: 7428181
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of serum creatinine by reaction with methyl-3,5-dinitrobenzoate in Methyl Sulfoxide.
    Sims C; Parekh AC
    Ann Clin Biochem; 1977 Jul; 14(4):227-32. PubMed ID: 20028
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of endogenous and exogenous Jaffé-reaction-positive pseudo-creatinine chromogens in determination of creatinine in blood of normal and cephaloridine-administered rats.
    Kuwagaki Y; Sudo J
    J Toxicol Sci; 1989 Feb; 14(1):23-31. PubMed ID: 2738963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reactivity of acetoacetate with alkaline picrate: an interference of the Jaffé reaction.
    Blass KG; Ng DS
    Clin Biochem; 1988 Jan; 21(1):39-47. PubMed ID: 3345598
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reaction of picrate with creatinine and cepha antibiotics.
    Kroll MH; Hagengruber C; Elin RJ
    Clin Chem; 1984 Oct; 30(10):1664-6. PubMed ID: 6478596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 1. Alkalinity controlled with NaOH.
    Pardue HL; Bacon BL; Nevius MG; Skoug JW
    Clin Chem; 1987 Feb; 33(2 Pt 1):278-85. PubMed ID: 3802512
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reaction of alkaline sodium picrate with creatinine: I. Kinetics and mechanism of formation of the mono-creatinine picric acid complex.
    Vasiliades J
    Clin Chem; 1976 Oct; 22(10):1664-71. PubMed ID: 10095
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Kinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.
    Diamandis EP; Hadjiioannou TP
    Clin Chem; 1981 Mar; 27(3):455-7. PubMed ID: 7471397
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Positive interference with the Jaffé reaction by cephalosporin antibiotics.
    Swain RR; Briggs SL
    Clin Chem; 1977 Jul; 23(7):1340-2. PubMed ID: 872385
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 2. Evaluation of buffered reagent and comparison of different data-processing options.
    Bacon BL; Pardue HL
    Clin Chem; 1989 Mar; 35(3):360-3. PubMed ID: 2920402
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modification of the alkaline picrate assay for creatinine to prevent spuriously elevated values by keto acids.
    Kammeraat C
    Clin Chim Acta; 1978 Mar; 84(1-2):119-28. PubMed ID: 639295
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oxidation markedly reduces bilirubin interference in the Jaffé creatinine assay.
    Rajs G; Mayer M
    Clin Chem; 1992 Dec; 38(12):2411-3. PubMed ID: 1333917
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Picric acid methods greatly overestimate serum creatinine in mice: more accurate results with high-performance liquid chromatography.
    Meyer MH; Meyer RA; Gray RW; Irwin RL
    Anal Biochem; 1985 Jan; 144(1):285-90. PubMed ID: 3985323
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated reaction-rate method for determination of serum creatinine with the CentrifiChem.
    Fabiny DL; Ertingshausen G
    Clin Chem; 1971 Aug; 17(8):696-700. PubMed ID: 5562281
    [No Abstract]   [Full Text] [Related]  

  • 15. Investigations into negative interference by jaundiced plasma in kinetic Jaffé methods for plasma creatinine determination.
    Knapp ML; Hadid O
    Ann Clin Biochem; 1987 Jan; 24 ( Pt 1)():85-97. PubMed ID: 3827191
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Specific creatinine determination in laboratory animals using the new enzymatic test kit "Creatinine-PAP".
    Jung K; Wesslau C; Priem F; Schreiber G; Zubek A
    J Clin Chem Clin Biochem; 1987 Jun; 25(6):357-61. PubMed ID: 3625134
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rifampicin and isoniazid behave as non-creatinine chromogens and interfere with Jaffe's reaction: A phenomenon with the potential to give a false-positive result in creatinine estimation.
    Kumar D; Singh S; Kaur S; Kumari M; Bhattacharyya R; Banerjee D
    Indian J Tuberc; 2020 Apr; 67(2):253-256. PubMed ID: 32553320
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanism of cefoxitin and cephalothin interference with the Jaffé method for creatinine.
    Kroll MH; Elin RJ
    Clin Chem; 1983 Dec; 29(12):2044-8. PubMed ID: 6640898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of creatinine error in ketotic patients. A prospective comparison of alkaline picrate methods with an enzymatic method.
    Gerard SK; Khayam-Bashi H
    Am J Clin Pathol; 1985 Nov; 84(5):659-64. PubMed ID: 4061391
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Specific method for serum creatinine determination based on ion exchange chromatography and an automated alkaline picrate reaction -- a proposed reference method.
    Weatherburn MW; Trotman RB; Jackson SH
    Clin Biochem; 1978 Aug; 11(4):159-66. PubMed ID: 30547
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.