These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
134 related articles for article (PubMed ID: 7428397)
21. The technique of detecting systolic and diastolic pressure from the transducer output of a PC-based blood pressure monitoring system. Rahman MS; Parveen R; Kabir KH Comput Methods Biomech Biomed Engin; 2007 Dec; 10(6):409-17. PubMed ID: 17891676 [TBL] [Abstract][Full Text] [Related]
22. A pressure-measuring system for long-term in vivo pressure measurements. Rosenberg G; Pierce WS; Brighton JA; Phillips WM; Landis DL; Lenker J Surgery; 1976 Apr; 79(4):456-9. PubMed ID: 1257907 [TBL] [Abstract][Full Text] [Related]
23. Prehospital Invasive Arterial Pressure: Use of a Minimized Flush System. Karlsson J; Linde J; Svensen C; Gellerfors M Prehosp Disaster Med; 2018 Oct; 33(5):490-494. PubMed ID: 30168412 [TBL] [Abstract][Full Text] [Related]
24. Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system. Levy RD; Cunningham D; Shapiro LM; Wright C; Mockus L; Fox KM Br Heart J; 1986 Apr; 55(4):336-43. PubMed ID: 3964499 [TBL] [Abstract][Full Text] [Related]
25. Calibration and assessment of a fluid-filled catheter-transducer system for the measurement of ventricular diastolic pressures. Brennan EG; O'Hare NJ Physiol Meas; 1998 Aug; 19(3):405-12. PubMed ID: 9735891 [TBL] [Abstract][Full Text] [Related]
26. A new optical transducer for arterial pressure measurement. Hackman CH; Tan PS; Chakrabarti MK; Whitwam JG Br J Anaesth; 1991 Sep; 67(3):346-52. PubMed ID: 1911027 [TBL] [Abstract][Full Text] [Related]
27. Wideband external pulse recording during cuff deflation: a new technique for evaluation of the arterial pressure pulse and measurement of blood pressure. Blank SG; West JE; Müller FB; Cody RJ; Harshfield GA; Pecker MS; Laragh JH; Pickering TG Circulation; 1988 Jun; 77(6):1297-305. PubMed ID: 3370770 [TBL] [Abstract][Full Text] [Related]
28. Experimental evaluation of a new transducer tipped catheter. Kar S; Drury JK; Tokioka H; Meerbaum S; Corday E Indian Heart J; 1989; 41(4):213-20. PubMed ID: 2807355 [TBL] [Abstract][Full Text] [Related]
29. [French Society of Anesthesia and Intensive Care. Arterial catheterization and invasive measurement of blood pressure in anesthesia and intensive care in adults]. Ann Fr Anesth Reanim; 1995; 14(5):444-53. PubMed ID: 8572416 [TBL] [Abstract][Full Text] [Related]
30. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)]. Hellige G Basic Res Cardiol; 1976; 71(4):389-406. PubMed ID: 971217 [TBL] [Abstract][Full Text] [Related]
31. Radial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement. Weiss BM; Spahn DR; Rahmig H; Rohling R; Pasch T Br J Anaesth; 1996 Mar; 76(3):405-11. PubMed ID: 8785142 [TBL] [Abstract][Full Text] [Related]
32. Thin fluid-filled catheters for more accurate determination of pressures and their time derivatives. Lomholt N; Bille-Brahe NE; Andersen HR; Djuurhus JC; Bredgaard M Acta Chir Scand Suppl; 1980; 502():27-32. PubMed ID: 6941598 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of catheter-manometer systems for adequate intravascular blood pressure measurements in small animals. Idvall J; Aronsen KF; Lindström K; Ulmsten U Res Exp Med (Berl); 1977 Sep; 171(2):101-10. PubMed ID: 928971 [TBL] [Abstract][Full Text] [Related]
34. Failure of disposable domes to prevent septicemia acquired from contaminated pressure transducers. Buxton AE; Anderson RL; Klimek J; Quintiliani R Chest; 1978 Nov; 74(5):508-13. PubMed ID: 738087 [TBL] [Abstract][Full Text] [Related]
35. Semi-invasive method for instantaneous and phasic measurement of arterial blood pressure. Sabbah HN; Stein PD Med Instrum; 1976; 10(4):189-92. PubMed ID: 958045 [TBL] [Abstract][Full Text] [Related]
36. Experimental analysis of catheter-manometer systems in vitro and in vivo. Hipkins SF; Rutten AJ; Runciman WB Anesthesiology; 1989 Dec; 71(6):893-906. PubMed ID: 2589678 [TBL] [Abstract][Full Text] [Related]
37. A catheter-manometer calibrator--a new clinical instrument. Asmussen M; Lindström K; Ulmsten U Biomed Eng; 1975 May; 10(5):175-80. PubMed ID: 1125361 [TBL] [Abstract][Full Text] [Related]
38. [Registration and evaluation of blood pressure curves of the pulmonary artery with reference to various causes of error]. Weller W Z Kardiol; 1975 Jan; 64(1):68-83. PubMed ID: 1114865 [TBL] [Abstract][Full Text] [Related]
39. Invasive arterial BP monitoring in trauma and critical care: effect of variable transducer level, catheter access, and patient position. McCann UG; Schiller HJ; Carney DE; Kilpatrick J; Gatto LA; Paskanik AM; Nieman GF Chest; 2001 Oct; 120(4):1322-6. PubMed ID: 11591577 [TBL] [Abstract][Full Text] [Related]