277 related articles for article (PubMed ID: 7431981)
1. Clinical durability of the Hancock porcine bioprosthetic valve.
Oyer PE; Miller DC; Stinson EB; Reitz BA; Moreno-Cabral RJ; Shumway NE
J Thorac Cardiovasc Surg; 1980 Dec; 80(6):824-33. PubMed ID: 7431981
[TBL] [Abstract][Full Text] [Related]
2. Eighteen-year follow up after Hancock II bioprosthesis insertion.
Legarra JJ; Llorens R; Catalan M; Segura I; Trenor AM; de Buruaga JS; Rabago G; Sarralde A
J Heart Valve Dis; 1999 Jan; 8(1):16-24. PubMed ID: 10096477
[TBL] [Abstract][Full Text] [Related]
3. Twenty-year clinical experience with porcine bioprostheses.
Fann JI; Miller DC; Moore KA; Mitchell RS; Oyer PE; Stinson EB; Robbins RC; Reitz BA; Shumway NE
Ann Thorac Surg; 1996 Nov; 62(5):1301-11; discussion 1311-2. PubMed ID: 8893561
[TBL] [Abstract][Full Text] [Related]
4. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.
Mykén PS
J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875
[TBL] [Abstract][Full Text] [Related]
5. Twenty-year results of the Hancock II bioprosthesis.
Borger MA; Ivanov J; Armstrong S; Christie-Hrybinsky D; Feindel CM; David TE
J Heart Valve Dis; 2006 Jan; 15(1):49-55; discussion 55-6. PubMed ID: 16480012
[TBL] [Abstract][Full Text] [Related]
6. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis.
Mykén P; Bech-Hanssen O; Phipps B; Caidahl K
J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100
[TBL] [Abstract][Full Text] [Related]
7. Mechanical versus bioprosthetic valve replacement in middle-aged patients.
Kulik A; Bédard P; Lam BK; Rubens FD; Hendry PJ; Masters RG; Mesana TG; Ruel M
Eur J Cardiothorac Surg; 2006 Sep; 30(3):485-91. PubMed ID: 16857373
[TBL] [Abstract][Full Text] [Related]
8. Early mechanical failures of the Hancock pericardial xenograft.
Bortolotti U; Milano A; Thiene G; Guerra F; Mazzucco A; Valente M; Talenti E; Gallucci V
J Thorac Cardiovasc Surg; 1987 Aug; 94(2):200-7. PubMed ID: 3613618
[TBL] [Abstract][Full Text] [Related]
9. An eight-year experience with porcine bioprosthetic cardiac valves.
Hartz RS; Fisher EB; Finkelmeier B; DeBoer A; Sanders JH; Moran JM; Michaelis LL
J Thorac Cardiovasc Surg; 1986 Jun; 91(6):910-7. PubMed ID: 3713240
[TBL] [Abstract][Full Text] [Related]
10. Carpentier-Edwards porcine bioprostheses: clinical performance assessed by actual analysis.
Jamieson WR; Miyagishima RT; Burr LH; Lichtenstein SV; Fradet GJ; Janusz MT
J Heart Valve Dis; 2000 Jul; 9(4):530-5. PubMed ID: 10947046
[TBL] [Abstract][Full Text] [Related]
11. Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes?
Alsoufi B; Manlhiot C; McCrindle BW; Canver CC; Sallehuddin A; Al-Oufi S; Joufan M; Al-Halees Z
Eur J Cardiothorac Surg; 2009 Jul; 36(1):84-90; discussion 90. PubMed ID: 19369085
[TBL] [Abstract][Full Text] [Related]
12. Clinical experience with the Carpentier-Edwards porcine bioprosthesis: short-term results (from 2 to 4.5 years).
Gallo I; Ruiz B; Duran CM
Thorac Cardiovasc Surg; 1983 Oct; 31(5):277-81. PubMed ID: 6196860
[TBL] [Abstract][Full Text] [Related]
13. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
[TBL] [Abstract][Full Text] [Related]
14. Five-year evaluation of the Carpentier-Edwards porcine bioprosthesis.
Jamieson WR; Pelletier LC; Janusz MT; Chaitman BR; Tyers FO; Miyagishima RT
J Thorac Cardiovasc Surg; 1984 Sep; 88(3):324-33. PubMed ID: 6381888
[TBL] [Abstract][Full Text] [Related]
15. Long-term experience with porcine aortic valve xenografts.
Stinson EB; Griepp RB; Oyer PE; Shumway NE
J Thorac Cardiovasc Surg; 1977 Jan; 73(1):54-63. PubMed ID: 556634
[TBL] [Abstract][Full Text] [Related]
16. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
Murakami T; Eishi K; Nakano S; Kobayashi J; Sasako Y; Isobe F; Kosakai Y; Kito Y; Kawashima Y
J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
[TBL] [Abstract][Full Text] [Related]
17. Medtronic mosaic porcine bioprosthesis: investigational center experience to six years.
Jamieson WR; Fradet GJ; MacNab JS; Burr LH; Stanford EA; Janusz MT; Abel JG; Germann E; Cheung A
J Heart Valve Dis; 2005 Jan; 14(1):54-63. PubMed ID: 15700437
[TBL] [Abstract][Full Text] [Related]
18. The Mitroflow pericardial bioprosthesis. Comparison of early clinical performance in aortic and mitral positions.
Jamieson WR; Pelletier LC; Gerein AN; Pomar J
Can J Surg; 1992 Apr; 35(2):159-64. PubMed ID: 1562925
[TBL] [Abstract][Full Text] [Related]
19. Carpentier-Edwards bioprosthesis: a 7-year follow-up in 361 patients.
Zussa C; Del Ponte S; Ottino GM; Pansini S; Zattera G; Morea M
Thorac Cardiovasc Surg; 1986 Aug; 34(4):252-7. PubMed ID: 2429394
[TBL] [Abstract][Full Text] [Related]
20. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement.
Emery RW; Krogh CC; Arom KV; Emery AM; Benyo-Albrecht K; Joyce LD; Nicoloff DM
Ann Thorac Surg; 2005 Mar; 79(3):776-82; discussion 782-3. PubMed ID: 15734375
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]