These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 7440270)

  • 21. Single-breath nitrogen test in excised human lungs.
    Berend N; Skoog C; Thurlbeck WM
    J Appl Physiol Respir Environ Exerc Physiol; 1981 Dec; 51(6):1568-73. PubMed ID: 7319885
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Breath-by-breath measurement of true alveolar gas exchange.
    Beaver WL; Lamarra N; Wasserman K
    J Appl Physiol Respir Environ Exerc Physiol; 1981 Dec; 51(6):1662-75. PubMed ID: 6798003
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Computerized, noninvasive tests of lung function. A flexible approach using mass spectrometry.
    Guy HJ; Gaines RA; Hill PM; Wagner PD; WEST JB
    Am Rev Respir Dis; 1976 Jun; 113(6):737-44. PubMed ID: 937814
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The carbon monoxide diffusing capacity of the lung in normal subjects.
    HOLLAND RA; BLACKET RB
    Australas Ann Med; 1958 Aug; 7(3):192-204. PubMed ID: 13584265
    [No Abstract]   [Full Text] [Related]  

  • 25. [Studies on measurement of residual volume by using a single breath nitrogen method].
    Sugita M; Kitada O; Nobuta M; Miyauchi M; Matsuoka A
    Rinsho Byori; 1982 May; 30(5):563-7. PubMed ID: 7131825
    [No Abstract]   [Full Text] [Related]  

  • 26. Fractional carbon monoxide uptake and "diffusing capacity" in models of pulmonary maldistribution.
    Harris EA; Whitlock RM
    Bull Eur Physiopathol Respir; 1983; 19(5):427-32. PubMed ID: 6640162
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Variability of respiratory function tests 9 weeks observation (author's transl)].
    Pham QT; Mur JM; Gimenez M; Mastrangelo G; Henquel JC
    Rev Epidemiol Sante Publique; 1981; 29(1):15-26. PubMed ID: 7255826
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Lung diffusing capacity for nitric oxide and carbon monoxide: dependence on breath-hold time.
    Dressel H; Filser L; Fischer R; de la Motte D; Steinhaeusser W; Huber RM; Nowak D; Jörres RA
    Chest; 2008 May; 133(5):1149-54. PubMed ID: 18263682
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Clinical application of dynamic lung imaging by the single breath measurement with carbon-11-labeled CO2, CO and nitrogen-13-labeled N2 (author's transl)].
    Kimura K; Rikitake T; Matsumoto T; Tateno Y; Hasegawa S
    Kaku Igaku; 1979 Sep; 16(6):907-16. PubMed ID: 522313
    [No Abstract]   [Full Text] [Related]  

  • 30. Cardiogenic oscillations in He and SF6 expirograms during airway and venous loading.
    Meyer M; Lewis SM; Mohr M; Schulz H; Schuster KD; Piiper J
    J Appl Physiol (1985); 1990 Sep; 69(3):945-55. PubMed ID: 2123180
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Determination of alveolar ventilation by carbon monoxide. Comparative study with the Enghoff-Rossier method].
    Prefaut C; Ramonatxo M; Chardon G
    C R Seances Soc Biol Fil; 1972; 166(8):1033-6. PubMed ID: 4660166
    [No Abstract]   [Full Text] [Related]  

  • 32. Determinants of the slope of phase III of the single breath nitrogen test.
    Berend N; Glanville AR; Grunstein MM
    Bull Eur Physiopathol Respir; 1984; 20(6):521-7. PubMed ID: 6518315
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Proceedings: Measurement of transfer factor for oxygen (T1,02) and for carbon monoxide by single-breath method (T1,COsb).
    Frans A
    Proc R Soc Med; 1973 Oct; 66(10):977-8. PubMed ID: 4595706
    [No Abstract]   [Full Text] [Related]  

  • 34. Hybrid computer studies of ventilatory distribution and lung volume. I. Normal newborn infants.
    Hanson JS; Shinozaki T
    Pediatrics; 1970 Dec; 46(6):900-14. PubMed ID: 4923513
    [No Abstract]   [Full Text] [Related]  

  • 35. Measurement of closing volume with the single breath nitrogen method.
    Oxhøj H; Bake B
    Scand J Respir Dis; 1974; 55(6):320-31. PubMed ID: 4462206
    [No Abstract]   [Full Text] [Related]  

  • 36. Cardiogenic oscillation and phase III caused by pressure-volume heterogeneity: a model.
    Arieli R; Wiener F; Levitan E
    J Appl Physiol (1985); 1986 Jun; 60(6):2101-8. PubMed ID: 3722074
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Small-sample reproducibility estimates: an example using rebreathing measurements.
    Jensen RL; Crapo RO; Mason JD; Yanowitz FG
    J Appl Physiol (1985); 1990 Apr; 68(4):1717-21. PubMed ID: 2347809
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Alveolar ventilation (in normal subjects) analyzed breath by breath as nitrogen elimination during oxygen breathing.
    LUNDIN G
    Scand J Clin Lab Invest; 1955; 7 Suppl 20():39-51. PubMed ID: 13298626
    [No Abstract]   [Full Text] [Related]  

  • 39. Decreasing size of cardiogenic oscillations reflects decreasing compliance of the respiratory system during long-term ventilation.
    Lichtwarck-Aschoff M; Suki B; Hedlund A; Sjöstrand UH; Markström A; Kawati R; Hedenstierna G; Guttmann J
    J Appl Physiol (1985); 2004 Mar; 96(3):879-84. PubMed ID: 14578363
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Lung mechanics and pulmonary gas exchange after hyperbaric oxygenation (author's transl)].
    Gerbershagen HU; Kuffner HD; Rocker H
    Anaesthesist; 1977 Aug; 26(8):433-52. PubMed ID: 907077
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.