These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 7444762)

  • 1. Optimal preparation techniques for human saphenous vein grafts.
    Gundry SR; Jones M; Ishihara T; Ferrans VJ
    Surgery; 1980 Dec; 88(6):785-94. PubMed ID: 7444762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An improved technique for preservation of endothelial morphology in vein grafts.
    LoGerfo FW; Quist WC; Crawshaw HM; Haudenschild C
    Surgery; 1981 Dec; 90(6):1015-24. PubMed ID: 7313936
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of cold cardioplegic solution for vein graft distention and preservation: a light and scanning electron microscopic study.
    Kurusz M; Christman EW; Derrick JR; Tyers GF; Williams EH
    Ann Thorac Surg; 1981 Jul; 32(1):68-74. PubMed ID: 6972750
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of harvesting technique on endothelial preservation in saphenous veins.
    Dries D; Mohammad SF; Woodward SC; Nelson RM
    J Surg Res; 1992 Mar; 52(3):219-25. PubMed ID: 1538597
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrastructure of human and transplanted canine veins: effects of different preparation media.
    Sottiurai VS; Stanley JC; Fry WJ
    Surgery; 1983 Jan; 93(1 Pt 1):28-38. PubMed ID: 6849185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. University of Wisconsin solution and human saphenous vein graft preservation: preliminary anatomic report.
    Santoli E; Di Mattia D; Boldorini R; Mingoli A; Tosoni A; Santoli C
    Eur J Cardiothorac Surg; 1993; 7(10):548-52. PubMed ID: 8267997
    [TBL] [Abstract][Full Text] [Related]  

  • 7. "No-touch" technique using saphenous vein harvested with its surrounding tissue for coronary artery bypass grafting maintains an intact endothelium.
    Souza DS; Christofferson RH; Bomfim V; Filbey D
    Scand Cardiovasc J; 1999; 33(6):323-9. PubMed ID: 10622542
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prevention of endothelial damage during preparation of saphenous veins for bypass grafting.
    Bonchek LI
    J Thorac Cardiovasc Surg; 1980 Jun; 79(6):911-5. PubMed ID: 6768934
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cold induced endothelial cell detachment in human saphenous vein grafts.
    Solberg S; Larsen T; Jørgensen L; Sørlie D
    J Cardiovasc Surg (Torino); 1987; 28(5):571-5. PubMed ID: 3654742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimal techniques for harvesting and preparation of reversed autogenous vein grafts for use as arterial substitutes: a review.
    Adcock OT; Adcock GL; Wheeler JR; Gregory RT; Snyder SO; Gayle RG
    Surgery; 1984 Nov; 96(5):886-94. PubMed ID: 6387991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intraoperative trauma to human saphenous veins: scanning electron microscopic comparison of preparation techniques.
    Gundry SR; Jones M; Ishihara T; Ferrans VJ
    Ann Thorac Surg; 1980 Jul; 30(1):40-7. PubMed ID: 6772117
    [No Abstract]   [Full Text] [Related]  

  • 12. Comparison of saphenous vein graft relaxation between Plasma-Lyte solution and normal saline solution.
    Sanchez AM; Wooldridge TA; Boerboom LE; Olinger GN; Almassi GH; Rusch NJ
    J Thorac Cardiovasc Surg; 1994 Jun; 107(6):1445-53. PubMed ID: 8196386
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preservation of endothelial vascular function of saphenous vein grafts after long-time storage with a recently developed potassium-chloride and N-acetylhistidine enriched storage solution.
    Wilbring M; Tugtekin SM; Zatschler B; Ebner A; Reichenspurner H; Kappert U; Matschke K; Deussen A
    Thorac Cardiovasc Surg; 2013 Dec; 61(8):656-62. PubMed ID: 22791204
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A technique for preparation of saphenous vein grafts.
    DePalma RG
    Surg Gynecol Obstet; 1976 Nov; 143(5):800-801. PubMed ID: 982263
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Storage of donor long saphenous vein.
    Davies AH; Parums DV
    J Cardiovasc Surg (Torino); 1992; 33(1):92-7. PubMed ID: 1545005
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of preservation solution and distension pressure on saphenous vein's endothelium.
    Pimentel MD; Lobo Filho JG; Lobo Filho HG; de Castro Miguel E; Pinheiro Paiva SK; Silva Matos JI; Mesquita Fernandes MA; Fechine Jamacaru FV
    Interact Cardiovasc Thorac Surg; 2022 Aug; 35(3):. PubMed ID: 35575424
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Degenerative changes of vein grafts in preparation media: preliminary studies by electron microscopy and fibrinolytic autography.
    Nakamura H; Iwai T; Hatano R
    Jpn J Surg; 1978 Dec; 8(4):333-41. PubMed ID: 732056
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Even short-time storage in physiological saline solution impairs endothelial vascular function of saphenous vein grafts.
    Wilbring M; Tugtekin SM; Zatschler B; Ebner A; Reichenspurner H; Matschke K; Deussen A
    Eur J Cardiothorac Surg; 2011 Oct; 40(4):811-5. PubMed ID: 21376620
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The natural history of endothelial structure and function in arterialized vein grafts.
    Bush HL; Jakubowski JA; Curl GR; Deykin D; Nabseth DC
    J Vasc Surg; 1986 Feb; 3(2):204-15. PubMed ID: 3511302
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The factors influencing early patency of coronary artery bypass vein grafts: correlation of angiographic and ultrastructural findings.
    Catinella FP; Cunningham JN; Srungaram RK; Baumann FG; Nathan IM; Glassman EA; Knopp EA; Spencer FC
    J Thorac Cardiovasc Surg; 1982 May; 83(5):686-700. PubMed ID: 6978974
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.