These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 7450375)

  • 1. Intracardiac electrogram parameters, electrode surface area and pacer input impedance: their correlations.
    Antonioli EG; Baggioni FG; Grassi G
    G Ital Cardiol; 1980; 10(5):536-53. PubMed ID: 7450375
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The ventricular endocardial electrogram and pacemaker sensing.
    Furman S; Hurzeler P; DeCaprio V
    J Thorac Cardiovasc Surg; 1977 Feb; 73(2):258-66. PubMed ID: 834065
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An integral equation model for intracardiac electrogram sensing.
    Sun W; Min X
    IEEE Trans Biomed Eng; 1997 Dec; 44(12):1237-42. PubMed ID: 9401223
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The interdependence between electrogram, total electrode impedance and pacemaker input impedance necessary to obtain adequate functioning of demand pacemakers.
    Ohm OJ
    Pacing Clin Electrophysiol; 1979 Jul; 2(4):465-85. PubMed ID: 95316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Physiological and electrical characteristics of the porous endocardial electrode.
    Amundson DC; MacCarter DJ; McArthur W; Mosharrafa M
    Med Instrum; 1979; 13(5):292-4. PubMed ID: 502928
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Understanding capture detection.
    de Voogt WG; Vonk BF; Albers BA; Hintringer F
    Europace; 2004 Nov; 6(6):561-9. PubMed ID: 15519259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The choice of the pacemaker-electrode combination.
    Thalen HJ
    G Ital Cardiol; 1978; 8 Suppl 1():81-6. PubMed ID: 754987
    [TBL] [Abstract][Full Text] [Related]  

  • 8. True bipolar defibrillator leads have increased sensing latency and threshold compared with the integrated bipolar configuration.
    Frain BH; Ellison KE; Michaud GF; Koo CH; Buxton AE; Kirk MM
    J Cardiovasc Electrophysiol; 2007 Feb; 18(2):192-5. PubMed ID: 17239139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pacemaker electrodes and problems related to cardiac pacing and sensing: current solutions and future trends.
    Pioger G; Garberoglio B
    Life Support Syst; 1984; 2(3):169-81. PubMed ID: 6503346
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exit block in pediatric cardiac pacing. Comparison of the suture-type and fishhook epicardial electrodes.
    DeLeon SY; Ilbawi MN; Backer CL; Idriss FS; Paul MH; Zales VR; Benson DW
    J Thorac Cardiovasc Surg; 1990 May; 99(5):905-10. PubMed ID: 2329830
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical results of far-field R-wave reduction with a short tip-ring electrode.
    De Groot JR; Schroeder-Tanka JM; Visser J; Willems AR; De Voogt WG
    Pacing Clin Electrophysiol; 2008 Dec; 31(12):1554-9. PubMed ID: 19067807
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Damages of malfunction of the electrostimulating system (author's transl)].
    Rossi P; D'Aulerio M; de Bellis F; Marino B; Palma G; Cattani A
    G Ital Cardiol; 1978; 8 Suppl 1():87-101. PubMed ID: 754988
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Stable stimulation impedance of steroid electrodes in various impulse amplitudes: indications for low polarization of the electrode-myocardium interface].
    Schuchert A; Kuck KH
    Z Kardiol; 1993 Jan; 82(1):41-5. PubMed ID: 8470419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of fractal-coated temporary pacing leads in the early postoperative course.
    Mellert F; Konietzko P; Schneider C; Gersing E; Kreuz J; Balta O; Preusse CJ; Welz A
    Pacing Clin Electrophysiol; 2008 Feb; 31(2):198-206. PubMed ID: 18233973
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Demand failures occurring during permanent pacing in patients with serious heart disease.
    Ohm OJ
    Pacing Clin Electrophysiol; 1980 Jan; 3(1):44-55. PubMed ID: 6160493
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characteristics of intracardiac electrograms.
    Myers GH; Kresh YM; Parsonnet V
    Pacing Clin Electrophysiol; 1978 Jan; 1(1):90-103. PubMed ID: 83626
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Worldwide evaluation of a defibrillation lead with a small geometric electrode surface for high-impedance pacing.
    Vollmann D; Ahern T; Gerritse B; Canby RC; Zenker D; Binner L; Kimber SK; Unterberg C;
    Am Heart J; 2003 Dec; 146(6):1066-70. PubMed ID: 14661000
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effects of electrode position on the detection of the transvenous cardiac electrogram.
    Hughes HC; Brownlee RR; Bertolet RD; Neff P; Sluetz JE; Tyers GF
    Pacing Clin Electrophysiol; 1980 Nov; 3(6):651-5. PubMed ID: 6161344
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Linear electrode arrays for stimulation and recording within cardiac tissue space constants.
    Pollard AE; Ellis CD; Smith WM
    IEEE Trans Biomed Eng; 2008 Apr; 55(4):1408-14. PubMed ID: 18390332
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polarization properties of small-surface-area pacemaker electrodes--implications on reliability of sensing and pacing.
    Fischler H
    Pacing Clin Electrophysiol; 1979 Jul; 2(4):403-16. PubMed ID: 95309
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.