These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 7451570)
1. Open aortic bioprosthesis at zero pressure. A new concept in glutaraldehyde fixation of tissue valve. Imamura E; Wada J J Cardiovasc Surg (Torino); 1980; 21(5):617-24. PubMed ID: 7451570 [TBL] [Abstract][Full Text] [Related]
2. Open versus closed position fixation of bioprosthesis. Comparative in vitro studies from the viewpoint of durability. Imamura E; Ohteki H; Tsutsui T; Nishiya Y; Ishihara S; Koyanagi H J Thorac Cardiovasc Surg; 1982 Apr; 83(4):610-7. PubMed ID: 7062772 [TBL] [Abstract][Full Text] [Related]
3. The influence of free hand suturing technique and zero pressure fixation on the hydrodynamic function of aortic root and aortic valve leaflets. Revanna P; Fisher J; Watterson KG Eur J Cardiothorac Surg; 1997 Feb; 11(2):280-6. PubMed ID: 9080156 [TBL] [Abstract][Full Text] [Related]
4. The influence of sizing and method of fixation on the hydrodynamic function of stentless, free-hand inserted porcine bioprosthesis: an in vitro study. Revanna P; Fisher J; Watterson KG J Heart Valve Dis; 1997 Jul; 6(4):433-8. PubMed ID: 9263877 [TBL] [Abstract][Full Text] [Related]
5. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro. Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J J Heart Valve Dis; 2001 Mar; 10(2):269-75. PubMed ID: 11297215 [TBL] [Abstract][Full Text] [Related]
6. Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves. Flomenbaum MA; Schoen FJ J Thorac Cardiovasc Surg; 1993 Jan; 105(1):154-64. PubMed ID: 8419696 [TBL] [Abstract][Full Text] [Related]
10. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep]. Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436 [TBL] [Abstract][Full Text] [Related]
11. [Continuous wave Doppler assessment of prosthetic valves in the mitral position: comparison of the St. Jude medical mechanical valve and the porcine xenograft valve]. Kisanuki A; Tei C; Arikawa K; Natsugoe K; Otsuji Y; Kawazoe Y; Tanaka H; Morishita Y; Maruko M; Taira A J Cardiogr; 1985 Dec; 15(4):1119-27. PubMed ID: 3841894 [TBL] [Abstract][Full Text] [Related]
12. Anatomy of aortic heart valve leaflets: the influence of glutaraldehyde fixation on function. Christie GW Eur J Cardiothorac Surg; 1992; 6 Suppl 1():S25-32; discussion S33. PubMed ID: 1389275 [TBL] [Abstract][Full Text] [Related]
13. Inflammation and infection in nine surgically explanted Medtronic Freestyle stentless aortic valves. Butany J; Zhou T; Leong SW; Cunningham KS; Thangaroopan M; Jegatheeswaran A; Feindel C; David TE Cardiovasc Pathol; 2007; 16(5):258-67. PubMed ID: 17868876 [TBL] [Abstract][Full Text] [Related]
14. The pulmonary bioprosthetic heart valve: its unsuitability for use as an aortic valve replacement. Jennings LM; Butterfield M; Booth C; Watterson KG; Fisher J J Heart Valve Dis; 2002 Sep; 11(5):668-78; discussion 679. PubMed ID: 12358404 [TBL] [Abstract][Full Text] [Related]
15. A novel pulse duplicator system: evaluation of different valve prostheses. Haaf P; Steiner M; Attmann T; Pfister G; Cremer J; Lutter G Thorac Cardiovasc Surg; 2009 Feb; 57(1):10-7. PubMed ID: 19169990 [TBL] [Abstract][Full Text] [Related]
16. Normal aortic valves stay open much longer in systole than porcine substitutes. Subhani M; Kumar RK; Balakrishnan KR Asian Cardiovasc Thorac Ann; 2013 Jun; 21(3):275-80. PubMed ID: 24570492 [TBL] [Abstract][Full Text] [Related]
17. Glutaraldehyde fixation alters the internal shear properties of porcine aortic heart valve tissue. Talman EA; Boughner DR Ann Thorac Surg; 1995 Aug; 60(2 Suppl):S369-73. PubMed ID: 7646190 [TBL] [Abstract][Full Text] [Related]
18. Biomechanics of glutaraldehyde-treated porcine aortic roots and valves. An investigation of the effect of predilation of the elastic aortic root. Lockie KJ; Fisher J; Juster NP; Davies GA; Watterson K J Thorac Cardiovasc Surg; 1994 Dec; 108(6):1037-42. PubMed ID: 7983873 [TBL] [Abstract][Full Text] [Related]
19. [Carotid pulse curve in patients with prosthetic aortic heart valves (author's transl)]. Schwab W; Raas E Wien Med Wochenschr; 1980 Jul; 130(13-14):475-8. PubMed ID: 7424036 [TBL] [Abstract][Full Text] [Related]
20. Finding the ideal biomaterial for aortic valve repair with ex vivo porcine left heart simulator and finite element modeling. Toeg HD; Abessi O; Al-Atassi T; de Kerchove L; El-Khoury G; Labrosse M; Boodhwani M J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1739-1745.e1. PubMed ID: 24930607 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]