These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 7457176)

  • 1. Blood flow into vascular catheters of different size and number of sideholes. Model experiments with flush fluid injections.
    Dahlborn M; Sundelius S
    Acta Radiol Diagn (Stockh); 1980; 21(4):469-75. PubMed ID: 7457176
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blood inflow into vascular catheters following injection of saline solution and contrast medium. Model experiments.
    Dahlborn M; Söderlund U
    Acta Radiol Diagn (Stockh); 1979; 20(3):439-45. PubMed ID: 525387
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood inflow into intra-arterial catheters following injection of contrast medium.
    Dahlborn M; Calissendorff B; Cronestrand R
    Acta Radiol Diagn (Stockh); 1978; 19(5):817-27. PubMed ID: 717032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blood inflow and coagulation in vascular catheters. Comparison of the effect of polysaccharide solutions, saline and contrast medium.
    Dahlborn M; Cronestrand R; Klintmalm G; Sundelius S
    Acta Radiol Diagn (Stockh); 1980; 21(6):715-20. PubMed ID: 7234484
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Augmented arterial flow and pressure resulting from selective injections through catheters: clinical implications.
    Levin DC
    Radiology; 1978 Apr; 127(1):103-8. PubMed ID: 635170
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of viscosity on power and hand injection of iso-osmolar iodinated contrast media through thin catheters.
    Zhang JJ; Hogstrom B; Malinak J; Ikei N
    Acta Radiol; 2016 May; 57(5):557-64. PubMed ID: 26185266
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood flow and blood volume determinations in aorta and in coronary circulation by density dilution.
    Moser M; Kenner T
    Basic Res Cardiol; 1988; 83(6):577-89. PubMed ID: 3223874
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical simulation of shear stress on the walls of peripheral arteries.
    Schima H; Tsangaris S; Zilla P; Kadletz M; Wolner E
    J Biomech; 1990; 23(8):845-51. PubMed ID: 2200788
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Simulation analysis in hemorheology (author's transl)].
    Azuma T; Fukushima T; Matsuzawa T
    Iyodenshi To Seitai Kogaku; 1981 Dec; 19(7):480-8. PubMed ID: 7047810
    [No Abstract]   [Full Text] [Related]  

  • 10. Angiographic methods for the study of fluid mechanical factors in atherogenesis.
    Smedby O
    Acta Radiol Suppl; 1992; 380():1-38. PubMed ID: 1414424
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complications of peripheral arteriography.
    Nunn DB
    Am Surg; 1978 Oct; 44(10):664-9. PubMed ID: 717898
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pressure-flow relationships in a model for the arterial system.
    Weygandt CN; Cox RH; Karreman G; Cole ML
    Bull Math Biol; 1978; 40(1):95-105. PubMed ID: 630154
    [No Abstract]   [Full Text] [Related]  

  • 13. The importance of viscoelasticity in arterial blood flow models.
    Saito GE; Werff TJ
    J Biomech; 1975 Jul; 8(3-4):237-45. PubMed ID: 1150692
    [No Abstract]   [Full Text] [Related]  

  • 14. Pressure and Flow Rate Changes During Contrast Injections in Cerebral Angiography: Correlation to Reflux Length.
    Kovarovic B; Woo HH; Fiorella D; Lieber BB; Sadasivan C
    Cardiovasc Eng Technol; 2018 Jun; 9(2):226-239. PubMed ID: 29497965
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Central venous catheters may be a potential source of massive air emboli during vascular procedures involving extracorporeal circulation: an experimental study.
    Høgetveit JO; Saatvedt K; Norum H; Kristiansen F; Elvebakk O; Dahle G; Geiran OR
    Perfusion; 2011 Jul; 26(4):341-6. PubMed ID: 21558301
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Cardiovascular physiology. Elasticity and viscoelasticity of the circulatory system. I. Physical basis. II. Arteries].
    Bettencourt MJ
    Rev Port Cardiol; 1994 Apr; 13(4):337-54,292. PubMed ID: 7917383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer simulation of arterial flow with applications to arterial and aortic stenoses.
    Stergiopulos N; Young DF; Rogge TR
    J Biomech; 1992 Dec; 25(12):1477-88. PubMed ID: 1491023
    [TBL] [Abstract][Full Text] [Related]  

  • 18. New principles for optimum left ventriculography.
    Hildner FJ; Furst A; Krieger R; Chengot M; Javier RP; Tolentino AO; Samet P
    Cathet Cardiovasc Diagn; 1986; 12(4):266-73. PubMed ID: 3757026
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of saline flush injection rate in displacement of CT-injectable peripherally inserted central catheter tip during power injection of contrast material.
    Morden P; Sokhandon F; Miller L; Savin M; Kirsch M; Farah M; Silbergleit R
    AJR Am J Roentgenol; 2014 Jan; 202(1):W13-8. PubMed ID: 24370160
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A nonlinear fluid model for pulmonary blood circulation.
    Li CW; Cheng HD
    J Biomech; 1993 Jun; 26(6):653-64. PubMed ID: 8514811
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.