These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 7466163)

  • 1. Evaluation of plasma protein antisera affinity by means of turbidimetric assays.
    Martorana GE; Barbaresi G; Zuppi C; Castelli A
    Ric Clin Lab; 1980; 10(1):289-93. PubMed ID: 7466163
    [No Abstract]   [Full Text] [Related]  

  • 2. Correlation of blood histamine levels with immunological indices in patients with Schönlein-Henoch purpura.
    Belcheva A; Mishkova R; Mutafova E
    Inflamm Res; 1996 Mar; 45 Suppl 1():S39-40. PubMed ID: 8696922
    [No Abstract]   [Full Text] [Related]  

  • 3. Comparability of some serum protein determinations by radial immunodiffusion, laser nephelometric and turbidimetric assays employing Q-antisera SEVAC.
    Bouzek J; Mancal P
    J Hyg Epidemiol Microbiol Immunol; 1989; 33(1):105-11. PubMed ID: 2498424
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry.
    Denham E; Mohn B; Tucker L; Lun A; Cleave P; Boswell DR
    Ann Clin Biochem; 2007 Nov; 44(Pt 6):529-36. PubMed ID: 17961307
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Normal values of IgA, IgG, IgM, a1-antitrypsin, C2-complement, C4-complement, ceruloplasmin, haptoglobin and transferrin in serum of healthy, matured newborns and comparison with adults. Method: kinetic nephelometry. (author's transl)].
    Liappis N; Schlebusch H; Hildenbrand G
    Klin Padiatr; 1981 Mar; 193(2):88-90. PubMed ID: 6971957
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Laser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.
    Guiguet M; Padieu P; Mack G; Dalebroux M
    J Clin Chem Clin Biochem; 1983 Apr; 21(4):217-21. PubMed ID: 6189960
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Some problems in the correction for intrinsic light-scattering of samples in specific protein analysis by automated immunoprecipitation.
    Shenkin A; Morrison B; Robertson DA
    Ann Clin Biochem; 1977 May; 14(3):163-70. PubMed ID: 326134
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [A turbidimetric method for the simple and economical determination of immunoglobulins G, A and M].
    Kunstmann FW
    Z Med Lab Diagn; 1985; 26(8):459-61. PubMed ID: 4096086
    [No Abstract]   [Full Text] [Related]  

  • 9. Rate immunonephelometric measurement of specific plasma proteins (an opportunity for control of analytical variance).
    Derry CK; Deaton CD; Gebott MD
    Ric Clin Lab; 1980; 10(1):267-72. PubMed ID: 6781048
    [No Abstract]   [Full Text] [Related]  

  • 10. The immunological aspects of sickle cell syndrome with particular reference to circulating immune complexes.
    Kazeem AA
    East Afr Med J; 1990 Nov; 67(11):761-9. PubMed ID: 2076676
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of circulating immune complexes in patients with atopic dermatitis and psoriasis.
    Kapp A; Kemper A; Schöpf E; Deicher H
    Acta Derm Venereol; 1986; 66(2):121-6. PubMed ID: 2424234
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High- and low-affinity antibodies--some observations in relation to polyethylene glycol concentration in immunoturbidimetric assays.
    Larsson K
    Scand J Clin Lab Invest; 1990 Apr; 50(2):217-20. PubMed ID: 2187241
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Determination of immunoglobulins by laser nephelometry using monospecific antisera].
    Rudnev VI; Osipov SG; Bakhov NI; Titov VN
    Lab Delo; 1984; (12):740-3. PubMed ID: 6084109
    [No Abstract]   [Full Text] [Related]  

  • 14. [Kinetic immunologic determination of specific serum proteins].
    Winkelmann U; Storm H
    Z Med Lab Diagn; 1980; 21(2):89-94. PubMed ID: 7415389
    [No Abstract]   [Full Text] [Related]  

  • 15. Proteins involved in the activation and control of the two pathways of human complement.
    Reid KB
    Biochem Soc Trans; 1983 Jan; 11(1):1-12. PubMed ID: 6298023
    [No Abstract]   [Full Text] [Related]  

  • 16. [Effect of immune complexes on immunoglobulin assays by turbidimetric immuno assay].
    Miura T; Yabuki S; Terasaki S; Hamazaki T; Ouchi E
    Rinsho Byori; 1985 Aug; 33(8):935-9. PubMed ID: 4079069
    [No Abstract]   [Full Text] [Related]  

  • 17. Removal of background interference in nephelometric determination of serum proteins.
    Kallner A
    Clin Chim Acta; 1977 Oct; 80(2):293-7. PubMed ID: 912903
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.
    Hills LP; Tiffany TO
    Clin Chem; 1980 Sep; 26(10):1459-66. PubMed ID: 7408174
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Affinity interactions of bacterial proteins with blood plasma components].
    Nikolaev VL
    Zh Mikrobiol Epidemiol Immunobiol; 1985 Aug; (8):108-15. PubMed ID: 2414951
    [No Abstract]   [Full Text] [Related]  

  • 20. An automated turbidimetric rate method for immunoglobulin assays.
    Malkus H; Buschbaum P; Castro A
    Clin Chim Acta; 1978 Sep; 88(3):523-30. PubMed ID: 100261
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.