174 related articles for article (PubMed ID: 7471397)
21. A general method for the assay of binders. Application to the potentiometric determination of albumin in human serum, plasma and whole blood.
Christopoulos TK; Diamandis EP
Clin Biochem; 1986 Jun; 19(3):151-60. PubMed ID: 3731433
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of serum creatinine measurement by the direct acidification method for errors contributed by non-creatinine chromogens.
Lolekha PH; Taksinamanee R
Clin Chim Acta; 1980 Oct; 107(1-2):97-104. PubMed ID: 7428181
[TBL] [Abstract][Full Text] [Related]
23. High-performance liquid-chromatographic measurement of plasma creatinine in newborns.
Scott PH
Clin Chem; 1992 Jan; 38(1):101-3. PubMed ID: 1733578
[TBL] [Abstract][Full Text] [Related]
24. Mechanism of cefoxitin and cephalothin interference with the Jaffé method for creatinine.
Kroll MH; Elin RJ
Clin Chem; 1983 Dec; 29(12):2044-8. PubMed ID: 6640898
[TBL] [Abstract][Full Text] [Related]
25. Kinetic and chemometric studies of the determination of creatinine using the Jaffé reaction. Part I. Kinetics of the reaction: analytical conclusions.
Llobat-Estellés M; Sevillano-Cabeza A; Campíns-Falcó P
Analyst; 1989 May; 114(5):597-602. PubMed ID: 2757229
[TBL] [Abstract][Full Text] [Related]
26. Mechanism of interference with the Jaffé reaction for creatinine.
Kroll MH; Roach NA; Poe B; Elin RJ
Clin Chem; 1987 Jul; 33(7):1129-32. PubMed ID: 3594839
[TBL] [Abstract][Full Text] [Related]
27. Kinetic study of the Jaffé reaction for quantifying creatinine in serum: 2. Evaluation of buffered reagent and comparison of different data-processing options.
Bacon BL; Pardue HL
Clin Chem; 1989 Mar; 35(3):360-3. PubMed ID: 2920402
[TBL] [Abstract][Full Text] [Related]
28. High-performance liquid chromatographic determination of creatinine in serum, and a correlation of the results with those of the Jaffé and enzymic methods.
Schneiderka P; Pacáková V; Stulík K; Kloudová M; Jelínková K
J Chromatogr; 1993 May; 614(2):221-6. PubMed ID: 8314933
[TBL] [Abstract][Full Text] [Related]
29. Portable microfluidic system for determination of urinary creatinine.
Songjaroen T; Maturos T; Sappat A; Tuantranont A; Laiwattanapaisal W
Anal Chim Acta; 2009 Aug; 647(1):78-83. PubMed ID: 19576389
[TBL] [Abstract][Full Text] [Related]
30. Kinetic determination of alkaline phosphatase activity based on hydrolytic cleavage of the P-F bond in monofluorophosphate and fluoride ion-selective electrode.
Venetz WP; Mangan C; Siddiqi IW
Anal Biochem; 1990 Nov; 191(1):127-32. PubMed ID: 2077934
[TBL] [Abstract][Full Text] [Related]
31. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.
Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C
Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313
[TBL] [Abstract][Full Text] [Related]
32. Immobilized enzyme electrode for creatinine determination in serum.
Nguyen VK; Wolff CM; Seris JL; Schwing JP
Anal Chem; 1991 Mar; 63(6):611-4. PubMed ID: 2031562
[TBL] [Abstract][Full Text] [Related]
33. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine.
Mizani F; Salmanzadeh Ardabili S; Ganjaliab MR; Faridbod F; Payehghadr M; Azmoodeh M
Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():861-868. PubMed ID: 25687018
[TBL] [Abstract][Full Text] [Related]
34. Potentiometric determination of cetylpyridinium chloride using a new type of screen-printed ion selective electrodes.
Mohamed GG; Ali TA; El-Shahat MF; Al-Sabagh AM; Migahed MA; Khaled E
Anal Chim Acta; 2010 Jul; 673(1):79-87. PubMed ID: 20630181
[TBL] [Abstract][Full Text] [Related]
35. Array of potentiometric sensors for the analysis of creatinine in urine samples.
Magalhães JM; Machado AA
Analyst; 2002 Aug; 127(8):1069-75. PubMed ID: 12195948
[TBL] [Abstract][Full Text] [Related]
36. Potentiometric determination of diazepam with a diazepam ion-selective electrode.
Nie LH; Liu DZ; Yao SZ
J Pharm Biomed Anal; 1990; 8(4):379-83. PubMed ID: 2100213
[No Abstract] [Full Text] [Related]
37. Specific creatinine determination in laboratory animals using the new enzymatic test kit "Creatinine-PAP".
Jung K; Wesslau C; Priem F; Schreiber G; Zubek A
J Clin Chem Clin Biochem; 1987 Jun; 25(6):357-61. PubMed ID: 3625134
[TBL] [Abstract][Full Text] [Related]
38. Comparison of plasma creatinine levels in patients determined by high-pressure liquid chromatography, automated analysis, and boiling alkaline picrate method.
Chiou WL; Peng GW; Gadalla MA; Nerenberg ST
J Pharm Sci; 1978 Feb; 67(2):292-3. PubMed ID: 23426
[No Abstract] [Full Text] [Related]
39. In-capillary determination of creatinine with electrophoretically mediated microanalysis: characterization of the effects of reagent zone and buffer conditions.
Mason PE; Schildt DC; Strein TG
J Chromatogr A; 2009 Jan; 1216(1):154-8. PubMed ID: 19046749
[TBL] [Abstract][Full Text] [Related]
40. Use of ion-selective electrodes in kinetic flow injection: determination of phenolic and hydrazino drugs with 1-fluoro-2,4-dinitrobenzene using a fluoride-selective electrode.
Apostolakis JC; Georgiou CA; Koupparis MA
Analyst; 1991 Mar; 116(3):233-7. PubMed ID: 1854019
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]