BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 7472603)

  • 21. [Combined scatter and attenuation correction for 201Tl myocardial perfusion SPECT using OS-EM algorithm].
    Matsuoka S; Shinohara H; Yamamoto T; Niio Y; Shima H; Yamada M; Hasebe S; Uchiyama K; Kuniyasu Y; Takahashi M; Yokoi T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1998 Nov; 58(13):751-7. PubMed ID: 9866992
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT.
    Kiat H; Germano G; Friedman J; Van Train K; Silagan G; Wang FP; Maddahi J; Berman D
    J Nucl Med; 1994 Apr; 35(4):542-8. PubMed ID: 8151372
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Multi-center study for the evaluation of clinical usefulness of attenuation and scatter correction on 201Tl myocardial SPECT].
    Tomiguchi S; Kumita S; Hashimoto J; Inoue T; Nomura Y; Emoto J; Nakajima K; Nishimura T
    Kaku Igaku; 2002 Feb; 39(1):37-46. PubMed ID: 11915311
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.
    Hademenos GJ; Dahlbom M; Hoffman EJ
    Eur J Nucl Med; 1995 May; 22(5):465-72. PubMed ID: 7641755
    [TBL] [Abstract][Full Text] [Related]  

  • 25. How precisely do SPECT images reflect tracer uptake in myocardial infarction? A comparison of thallium-201 and technetium-99m using a myocardial phantom.
    Onoguchi M; Maruno H; Takayama T; Murata H
    J Nucl Med Technol; 1998 Dec; 26(4):252-6. PubMed ID: 9884937
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A transmission-dependent method for scatter correction in SPECT.
    Meikle SR; Hutton BF; Bailey DL
    J Nucl Med; 1994 Feb; 35(2):360-7. PubMed ID: 8295011
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Scatter correction with an off-peak triple energy window method in thallium-201 imaging].
    Kojima A; Matsumoto M; Ohyama Y; Tomiguchi S; Kira M; Takahashi M
    Kaku Igaku; 1997 Sep; 34(9):789-96. PubMed ID: 9394545
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart.
    Ficaro EP; Fessler JA; Rogers WL; Schwaiger M
    J Nucl Med; 1994 Apr; 35(4):652-63. PubMed ID: 8151390
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.
    El Fakhri G; Buvat I; Benali H; Todd-Pokropek A; Di Paola R
    J Nucl Med; 2000 Aug; 41(8):1400-8. PubMed ID: 10945534
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Scatter correction in myocardial thallium SPECT: needs for optimization of energy window settings in the energy window-based scatter correction techniques].
    Narita Y; Iida H
    Kaku Igaku; 1999 Feb; 36(2):83-90. PubMed ID: 10213975
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Attenuation correction in cardiac SPECT without a transmission measurement.
    Wallis JW; Miller TR; Koppel P
    J Nucl Med; 1995 Mar; 36(3):506-12. PubMed ID: 7884518
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [201Tl, 99mTc-PYP dual SPECT].
    Sone T
    Nihon Rinsho; 1994 Jul; 52 Suppl(Pt 1):579-85. PubMed ID: 12436585
    [No Abstract]   [Full Text] [Related]  

  • 33. Scatter correction on its own increases image contrast in Tl-201 myocardium perfusion scintigraphy, but does it also improve diagnostic accuracy?
    Blokland KJ; de Vos tot Nederveen Cappel WH; van Eck-Smit BL; Pauwels EK
    Ann Nucl Med; 2003 Dec; 17(8):725-31. PubMed ID: 14971620
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Application of transmission scan-based attenuation compensation to scatter-corrected thallium-201 myocardial single-photon emission tomographic images.
    Hashimoto J; Ogawa K; Kubo A; Ichihara T; Motomura N; Takayama T; Iwanaga S; Mitamura H; Ogawa S
    Eur J Nucl Med; 1998 Feb; 25(2):120-7. PubMed ID: 9473258
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optimized energy window configuration for 201Tl imaging.
    Kalantari F; Rajabi H; Yaghoobi N
    J Nucl Med Technol; 2008 Mar; 36(1):36-43. PubMed ID: 18287194
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Scatter and attenuation correction for quantitative myocardial SPECT imaging].
    Hashimoto J; Sammiya T; Ogasawara K; Kubo A; Ogawa K; Ichihara T; Motomura N; Hasegawa H
    Kaku Igaku; 1996 Sep; 33(9):1015-9. PubMed ID: 8921671
    [TBL] [Abstract][Full Text] [Related]  

  • 37. CT-based SPECT attenuation correction and assessment of infarct size: results from a cardiac phantom study.
    Kroiss AS; Nekolla SG; Dobrozemsky G; Grubinger T; Shulkin BL; Schwaiger M
    Ann Nucl Med; 2017 Dec; 31(10):764-772. PubMed ID: 28936780
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Effect of scatter correction on quantification of myocardial SPECT and application to dual-energy acquisition using triple-energy window method].
    Nakajima K; Matsudaira M; Yamada M; Taki J; Tonami N; Hisada K
    Kaku Igaku; 1995 Sep; 32(9):959-67. PubMed ID: 8523844
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
    Hannequin PP; Mas JF
    J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [201Tl myocardial SPECT. First experiences with a simultaneous transmission-emission acquisition protocol for patient-specific attenuated correction].
    Knesewitsch P; Walser R; Kantlehner R; Münzing W; Hahn K
    Nuklearmedizin; 1996 Jun; 35(3):78-85. PubMed ID: 8710529
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.