These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

601 related articles for article (PubMed ID: 7474456)

  • 1. [Further evolution and leukocyte differential using an automated blood cell counter].
    Takubo T; Tatsumi N
    Rinsho Byori; 1995 Sep; 43(9):925-30. PubMed ID: 7474456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Developments of automated cell counter and its clinical laboratory application].
    Kimura T; Koyanagi Y; Sato K; Kurokawa I
    Rinsho Byori; 1991 Feb; 39(2):159-66. PubMed ID: 2041213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a new haematology analyser for whole blood count and full differential (NE-8000).
    Laharrague PF; Fillola G; Corberand JX
    Nouv Rev Fr Hematol (1978); 1992; 34(4):303-7. PubMed ID: 1448351
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of automated blood cell counter for the determination of polymorphonuclear cell count in the ascitic fluid of cirrhotic patients with or without spontaneous bacterial peritonitis.
    Angeloni S; Nicolini G; Merli M; Nicolao F; Pinto G; Aronne T; Attili AF; Riggio O
    Am J Gastroenterol; 2003 Aug; 98(8):1844-8. PubMed ID: 12907342
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality control in a manual and an automated leukocyte differential count.
    Takubo T; Tatsumi N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():66-74. PubMed ID: 10926263
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.
    Sanzari M; De Toni S; D'Osualdo A; Rossetti M; Floriani F; Plebani M
    Panminerva Med; 1998 Jun; 40(2):116-25. PubMed ID: 9689832
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
    Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
    Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automated leucocyte differentials in 292 patients with leucopenia: an evaluation of the Abbott CELL-DYN 3500 (CD3500) haematology analyser.
    Burchert-Graeve M; Kock R
    Clin Lab Haematol; 1996 Dec; 18(4):253-9. PubMed ID: 9054698
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the Beckman Coulter AcT 5 diff AL hematology analyzer in a hospital setting.
    Bhuta UM; Ulstein H
    Lab Hematol; 2003; 9(3):167-74. PubMed ID: 14521325
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Total nucleated cell differential for blood and bone marrow using a single tube in a five-color flow cytometer.
    Björnsson S; Wahlström S; Norström E; Bernevi I; O'Neill U; Johansson E; Runström H; Simonsson P
    Cytometry B Clin Cytom; 2008 Mar; 74(2):91-103. PubMed ID: 18061952
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analytic performance of the PENTRA 80 automated blood cell analyzer for the evaluation of normal and pathologic WBCs.
    Arroyo ME; Tabernero MD; García-Marcos MA; Orfao A
    Am J Clin Pathol; 2005 Feb; 123(2):206-14. PubMed ID: 15842044
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The H*1 hematology analyzer. Its performance characteristics and value in the diagnosis of infectious disease.
    Wenz B; Ramirez MA; Burns ER
    Arch Pathol Lab Med; 1987 Jun; 111(6):521-4. PubMed ID: 3579507
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [New technology of automated blood cell differential counting].
    Matsuno K; Ishizuka S
    Rinsho Byori; 1998 Apr; 46(4):361-6. PubMed ID: 9594627
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated cytochemistry and the white cell differential in leukemia.
    Ross DW; Bardwell A
    Blood Cells; 1980; 6(3):455-70. PubMed ID: 7397397
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pseudobasophilia as an erroneous white blood cell differential count with a discrepancy between automated cell counters: report of two cases.
    Hur M; Lee YK; Lee KM; Kim HJ; Cho HI
    Clin Lab Haematol; 2004 Aug; 26(4):287-90. PubMed ID: 15279666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Clinical reference values for laboratory hematology tests calculated using the iterative truncation method with correction: Part 2, Reference values for white blood cell (WBC) count, WBC differential including segmented neutrophil, band neutrophil, lymphocyte, monocyte, eosinophil, basophil, platelet count and mean platelet volume].
    Shiga S; Koyanagi I; Ohsaga J; Ichiyama S; Kannagi R
    Rinsho Byori; 1999 Mar; 47(3):281-8. PubMed ID: 10228396
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the automated leucocyte count and differential from the Cell-Dyn 3500 in sickle cell disease.
    Joyner RE; Brooks MJ
    Clin Lab Haematol; 1995 Dec; 17(4):329-33. PubMed ID: 8697728
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an automated method for leukocyte differential counts based on electronic volume analysis.
    Allen JK; Batjer JD
    Arch Pathol Lab Med; 1985 Jun; 109(6):534-9. PubMed ID: 3838883
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Automated leukocyte differential counters.
    J Health Care Technol; 1985; 2(1):51-72. PubMed ID: 10274624
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of white blood cell suspect flags and histogram pattern in the detection of acute leukemia by Advia-60 automated hematology analyzer.
    Kakkar N; Kaur R
    Indian J Pathol Microbiol; 2004 Jul; 47(3):322-6. PubMed ID: 16295415
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.