These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 7476076)

  • 1. Abbreviated moment-compensated phase encoding.
    Cao G; Parker DL; Sherrill DS; Du YP
    Magn Reson Med; 1995 Aug; 34(2):179-85. PubMed ID: 7476076
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flow compensation in balanced SSFP sequences.
    Bieri O; Scheffler K
    Magn Reson Med; 2005 Oct; 54(4):901-7. PubMed ID: 16142709
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow artifact reduction in MRI: a review of the roles of gradient moment nulling and spatial presaturation.
    Ehman RL; Felmlee JP
    Magn Reson Med; 1990 May; 14(2):293-307. PubMed ID: 2345509
    [TBL] [Abstract][Full Text] [Related]  

  • 4. FID-acquired-echos (FAcE): a short echo time imaging method for flow artefact suppression.
    Scheidegger MB; Maier SE; Boesiger P
    Magn Reson Imaging; 1991; 9(4):517-24. PubMed ID: 1779722
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Velocity encoding with the slice select refocusing gradient for faster imaging and reduced chemical shift-induced phase errors.
    Middione MJ; Thompson RB; Ennis DB
    Magn Reson Med; 2014 Jun; 71(6):2014-23. PubMed ID: 23836543
    [TBL] [Abstract][Full Text] [Related]  

  • 6. MR imaging of flow through tortuous vessels: a numerical simulation.
    van Tyen R; Saloner D; Jou LD; Berger S
    Magn Reson Med; 1994 Feb; 31(2):184-95. PubMed ID: 8133754
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Elimination of oblique flow artifacts in magnetic resonance imaging.
    Frank LR; Crawley AP; Buxton RB
    Magn Reson Med; 1992 Jun; 25(2):299-307. PubMed ID: 1614313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Gradient moment nulling in fast spin echo.
    Hinks RS; Constable RT
    Magn Reson Med; 1994 Dec; 32(6):698-706. PubMed ID: 7869891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. MRI pulse sequence design with first-order gradient moment nulling in arbitrary directions by solving a polynomial program.
    Majewski K; Heid O; Kluge T
    IEEE Trans Med Imaging; 2010 Jun; 29(6):1252-9. PubMed ID: 20304730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increased flexibility in GRASE imaging by k space-banded phase encoding.
    Feinberg DA; Johnson G; Kiefer B
    Magn Reson Med; 1995 Aug; 34(2):149-55. PubMed ID: 7476072
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real time blood flow imaging by spiral scan phase velocity mapping.
    Gatehouse PD; Firmin DN; Collins S; Longmore DB
    Magn Reson Med; 1994 May; 31(5):504-12. PubMed ID: 8015403
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Theoretical aspects of motion sensitivity and compensation in echo-planar imaging.
    Duerk JL; Simonetti OP
    J Magn Reson Imaging; 1991; 1(6):643-50. PubMed ID: 1823169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Velocity encoding and velocity compensation for multi-spoke RF excitation.
    Schmidt S; Flassbeck S; Bachert P; Ladd ME; Schmitter S
    Magn Reson Imaging; 2020 Feb; 66():69-85. PubMed ID: 31733267
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-time interactive color flow MR imaging.
    Riederer SJ; Wright RC; Ehman RL; Rossman PJ; Holsinger-Bampton AE; Hangiandreou NJ; Grimm RC
    Radiology; 1991 Oct; 181(1):33-9. PubMed ID: 1887053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance.
    Larson TC; Kelly WM; Ehman RL; Wehrli FW
    AJR Am J Roentgenol; 1990 Nov; 155(5):1117-24. PubMed ID: 2120946
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new frontier of blood imaging using susceptibility effect and tailored RF pulses.
    Ro YM; Cho ZH
    Magn Reson Med; 1992 Dec; 28(2):237-48. PubMed ID: 1461124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging.
    Bernstein MA; Shimakawa A; Pelc NJ
    J Magn Reson Imaging; 1992; 2(5):583-8. PubMed ID: 1392252
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High speed bolus tagging: time resolved velocity quantification of pulsatile flow in a single breath hold.
    Chien D; Saloner D; Laub G; Simonetti O; Anderson CM
    Magn Reson Med; 1994 Nov; 32(5):661-7. PubMed ID: 7808269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-to-noise ratios in maximum intensity projection images.
    Brown DG; Riederer SJ
    Magn Reson Med; 1992 Jan; 23(1):130-7. PubMed ID: 1734175
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Centric ordering is superior to gradient moment nulling for motion artifact reduction in EPI.
    Jaffer FA; Wen H; Jezzard P; Balaban RS; Wolff SD
    J Magn Reson Imaging; 1997; 7(6):1122-31. PubMed ID: 9400858
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.