These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 7476722)

  • 21. Dosimetric considerations for a multileaf collimator system.
    Palta JR; Yeung DK; Frouhar V
    Med Phys; 1996 Jul; 23(7):1219-24. PubMed ID: 8839416
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Calculating dose distributions and wedge factors for photon treatment fields with dynamic wedges based on a convolution/superposition method.
    Liu HH; McCullough EC; Mackie TR
    Med Phys; 1998 Jan; 25(1):56-63. PubMed ID: 9472826
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A depth dependence determination of the wedge transmission factor for 4-10 MV photon beams.
    McCullough EC; Gortney J; Blackwell CR
    Med Phys; 1988; 15(4):621-3. PubMed ID: 3211057
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [The improved determination of the dose rate in irregular photon fields].
    Fehrentz D; Hensley F; Oetzel D; Spyropoulos B; Vodolan P
    Strahlenther Onkol; 1992 Dec; 168(12):703-10. PubMed ID: 1481120
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Buildup region and depth of dose maximum of megavoltage x-ray beams.
    Sixel KE; Podgorsak EB
    Med Phys; 1994 Mar; 21(3):411-6. PubMed ID: 8208216
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Beam characteristics of upper and lower physical wedge systems of Varian accelerators.
    Cheng CW; Tang WL; Das IJ
    Phys Med Biol; 2003 Nov; 48(22):3667-83. PubMed ID: 14680266
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the scatter field for high-energy photon beam attenuators.
    Castellanos ME; Rosenwald JC
    Phys Med Biol; 1998 Feb; 43(2):277-90. PubMed ID: 9509526
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison of 4 MV photon surface dose among Varian, Siemens, and Elekta linear accelerators for tangential breast treatment: a phantom study.
    Yamaguchi S; Karasawa K; Furuya T; Fujita T; Tutumi Y; Miura K; Takada T; Ito K; Ozawa S
    Radiat Med; 2007 Jan; 25(1):8-13. PubMed ID: 17225047
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Multienergetic verification of dynamic wedge angles in medical accelerators using multichannel linear array.
    Kowalik A; Litoborski M
    Rep Pract Oncol Radiother; 2013; 18(4):220-34. PubMed ID: 24416557
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Wedge factor constituents of high energy photon beams: field size and depth dependence.
    Heukelom S; Lanson JH; Mijnheer BJ
    Radiother Oncol; 1994 Jan; 30(1):66-73. PubMed ID: 8153383
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The effects of a universal wedge and beam obliquity upon the central axis dose buildup for 6-MV x rays.
    McParland BJ
    Med Phys; 1991; 18(4):740-3. PubMed ID: 1921879
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monitor unit calculation for large wedged high-energy photon beams.
    Chen Z; Reinstein LE; Ramsay EB
    Phys Med Biol; 1995 Mar; 40(3):465-70. PubMed ID: 7732074
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monte Carlo modelling of a virtual wedge.
    Verhaegen F; Das IJ
    Phys Med Biol; 1999 Dec; 44(12):N251-9. PubMed ID: 10616157
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Shielding for neutron scattered dose to the fetus in patients treated with 18 MV x-ray beams.
    Roy SC; Sandison GA
    Med Phys; 2000 Aug; 27(8):1800-3. PubMed ID: 10984226
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of scatter generated by beam-modifying absorbers in megavoltage photon beams.
    Islam MK; Van Dyk J
    Med Phys; 1995 Dec; 22(12):2075-81. PubMed ID: 8746713
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Doses on the central axes of narrow 6-MV x-ray beams.
    Bjärngard BE; Tsai JS; Rice RK
    Med Phys; 1990; 17(5):794-9. PubMed ID: 2122197
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Calculating output factors for photon beam radiotherapy using a convolution/superposition method based on a dual source photon beam model.
    Liu HH; Mackie TR; McCullough EC
    Med Phys; 1997 Dec; 24(12):1975-85. PubMed ID: 9434980
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Wedge factor dependence with depth, field size, and nominal distance--a general computational rule.
    Popescu A; Lai K; Singer K; Phillips M
    Med Phys; 1999 Apr; 26(4):541-9. PubMed ID: 10227357
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electron contamination in clinical high energy photon beams.
    Sjögren R; Karlsson M
    Med Phys; 1996 Nov; 23(11):1873-81. PubMed ID: 8947901
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.